Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty.

Richard W McCalden1, Douglas D Naudie, Xunhua Yuan, Robert B Bourne.   

Abstract

All wear-measurement techniques assess femoral head penetration and therefore cannot distinguish between true polyethylene wear and bedding-in. Multiple wear measurements that are made at different time-intervals after bedding-in has occurred are required to determine the true wear rate. Computer-assisted edge-detection techniques offer improved accuracy and precision compared with manual techniques and appear to be ideally suited for the retrospective and prospective examination of large groups of patients with intermediate to long-term radiographic follow-up (more than five years). While radiostereometric analysis offers improved accuracy and precision compared with computer-assisted edge-detection techniques, widescale clinical application is limited because of its relative expense, the required expertise, and the fact that it can only be used in a prospective fashion.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16203901     DOI: 10.2106/JBJS.E.00223

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  33 in total

1.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

2.  Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance.

Authors:  Christoph J Siepe; Karsten Wiechert; Mohamed F Khattab; Andreas Korge; H Michael Mayer
Journal:  Eur Spine J       Date:  2007-01-05       Impact factor: 3.134

3.  Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Nucl Instrum Methods Phys Res B       Date:  2007-12       Impact factor: 1.377

4.  Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up.

Authors:  Matthew G Teeter; Colin J MacLean; Lyndsay E Somerville; James L Howard; Richard W McCalden; Brent A Lanting; Edward M Vasarhelyi
Journal:  J Orthop       Date:  2018-05-07

Review 5.  Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature.

Authors:  Hugo C van der Veen; Hans-Peter W van Jonbergen; Rudolf W Poolman; Sjoerd K Bulstra; Jos J A M van Raay
Journal:  Int Orthop       Date:  2012-12-11       Impact factor: 3.075

6.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

7.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

8.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

9.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

10.  Primary cemented total hip arthroplasty: 10 years follow-up.

Authors:  Rajendra Nath; Anil Kumar Gupta; Unmesh Chakravarty; Rohit Nath
Journal:  Indian J Orthop       Date:  2010-07       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.