Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits.

Alberto Goldenberg1, Jacques Matone, Wagner Marcondes, Fernando Augusto Mardiros Herbella, José Francisco de Mattos Farah.   

Abstract

PURPOSE: Compare, in a rabbit model, the inflammatory response and adhesions formation following surgical fixation of polypropilene and Vypro mesh in the inguinal preperitoneal space.
METHODS: Fourteen male New Zealand rabbits, weighing between 2.000 to 2.500 g were used. A midline incision was made and the peritoneal cavity was exposed. The 2.0 x 1.0 cm polypropylene mesh was fixed in the left flank and secured to the margins with 3-0 prolene in a separate pattern. In the right flank, a 2.0 x 1.0 cm Vypro II mesh was sewn in the same way. After the post surgical period, the animals were again anesthetized and underwent laparoscopic approach, in order to identify and evaluate adhesions degree. Both fixed prosthesis were excised bilaterally with the abdominal wall segment, including peritoneum, aponeurosis and muscle and sent to a pathologist.
RESULTS: Operative time ranged from 15 to 25 minutes and no difficulties in applying the mesh were found. From the 14 polypropylene meshes fixed to the intact peritoneum, 11 had adhesions to the abdominal cavity (78.6%). Concerning Vypro mesh, 12 animals developed adhesions from the 14 with mesh fixation (85.7%). Histological examination of tissues harvested revealed fibroblasts, collagen, macrophages and lymphocytes between the threads of the mesh.
CONCLUSION: Polypropylene and Vypro mesh, when implanted in the peritoneal cavity of rabbits provoke similar amount of adhesions. Vypro mesh tissues had higher fibrosis resulting in better mesh incorporation to the abdominal wall.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16186957     DOI: 10.1590/s0102-86502005000500002

Source DB:  PubMed          Journal:  Acta Cir Bras        ISSN: 0102-8650            Impact factor:   1.388


  13 in total

1.  Damage to the spermatic cord by the Lichtenstein and TAPP procedures in a pig model.

Authors:  Karsten Junge; Marcel Binnebösel; Caroline Kauffmann; Raphael Rosch; Christian Klink; Klaus von Trotha; Felix Schoth; Volker Schumpelick; Uwe Klinge
Journal:  Surg Endosc       Date:  2010-06-08       Impact factor: 4.584

2.  Collagen-coated vs noncoated low-weight polypropylene meshes in a sheep model for vaginal surgery. A pilot study.

Authors:  Renaud de Tayrac; Antoine Alves; Michel Thérin
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-08-29

Review 3.  Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Authors:  Dirk Weyhe; Orlin Belyaev; Christophe Müller; Kirsten Meurer; Karl-Heinz Bauer; Georgios Papapostolou; Waldemar Uhl
Journal:  World J Surg       Date:  2007-01       Impact factor: 3.352

4.  Experimental study comparing meshes made of polypropylene, polypropylene + polyglactin and polypropylene + titanium: inflammatory cytokines, histological changes and morphometric analysis of collagen.

Authors:  C G Pereira-Lucena; R Artigiani-Neto; G J Lopes-Filho; C V G Frazao; A Goldenberg; D Matos; M M Linhares
Journal:  Hernia       Date:  2010-01-14       Impact factor: 4.739

5.  Comparative efficacy of Prolene and Prolene-Vicryl composite mesh for experimental ventral hernia repair in dogs.

Authors:  H Anjum; S G Bokhari; M A Khan; M Awais; Z U Mughal; H K Shahzad; F Ijaz; M I Siddiqui; I U Khan; A S Chaudhry; R Akhtar; S Aslam; H Akbar; M Asif; M K Maan; M A Khan; A Noor; W A Khan; A Ullah; M A Hayat
Journal:  Iran J Vet Res       Date:  2016       Impact factor: 1.376

6.  [Pelvic lymphadenitis after total hip arthroplasty : Mimicking of lymph node metastases in a patient with prostate cancer].

Authors:  S Sevinc; C C Westhoff; A J Schrader; P J Olbert; R Hofmann; A Hegele
Journal:  Urologe A       Date:  2010-08       Impact factor: 0.639

7.  Influence of a new self-gripping hernia mesh on male fertility in a rat model.

Authors:  Thomas Kolbe; Christian Hollinsky; Ingrid Walter; Anja Joachim; Thomas Rülicke
Journal:  Surg Endosc       Date:  2009-07-02       Impact factor: 4.584

8.  Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model.

Authors:  K Junge; M Binnebösel; R Rosch; A Ottinger; M Stumpf; G Mühlenbruch; V Schumpelick; U Klinge
Journal:  Hernia       Date:  2008-07-02       Impact factor: 4.739

9.  Experimental study of inflammatory response and collagen morphometry with different types of meshes.

Authors:  C T Maeda; R Artigani Neto; G J Lopes-Filho; M M Linhares
Journal:  Hernia       Date:  2016-06-22       Impact factor: 4.739

10.  Consequences of endoscopic inguinal hernioplasty with mesh on subsequent open radical prostatectomy.

Authors:  S S Vijan; J C H Wall; S M Greenlee; D R Farley
Journal:  Hernia       Date:  2008-04-01       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.