Literature DB >> 20532568

Damage to the spermatic cord by the Lichtenstein and TAPP procedures in a pig model.

Karsten Junge1, Marcel Binnebösel, Caroline Kauffmann, Raphael Rosch, Christian Klink, Klaus von Trotha, Felix Schoth, Volker Schumpelick, Uwe Klinge.   

Abstract

BACKGROUND: Mesh implantation is regarded as the standard treatment of inguinal hernias. Obstructive azoospermia induced by mesh implantation is a rare but serious complication. Whether different operative techniques or mesh materials used have an effect on the integrity of the testicle and spermatic cord remains unclear. MATERIALS: In 12 minipigs a bilateral inguinal hernia repair, either open or laparoscopic, was performed using a standard small-pore polypropylene (PP) or large-pore polyvinyliden fluoride (PVDF) mesh. Next to measurement of the testicular size, thermography of the groin and testicle as a parameter for perfusion was performed preoperatively and at a follow-up at 6 months. Obstructions of the vas deferens were estimated radiographically. Testicular function (Johnson score) and mesh integration (granuloma size, apoptotic cells) were analyzed histologically.
RESULTS: Mean testicular size did not change significantly in follow-up compared to preoperative values. Technique and mesh material used failed to have a significant influence. Thermography of the groin following the Lichtenstein technique had significantly higher values at follow-up regardless of the mesh used. This could not been shown for laparoscopic treatment. Thermographic measurements at the testicle showed a significantly increased temperature in all groups compared to preoperative measurements. Only the Lichtenstein PP group showed significantly decreased values in testicular function. Quantity and quality of obstructions seen at vasography were most detectable in the Lichtenstein PP group. There was significantly decreased granuloma formation following PVDF mesh implantation compared to the PP mesh group regardless of the technique used.
CONCLUSIONS: Both the technique and the mesh material have an impact on integrity of spermatic cord and testicular function. According to the results of this study, the laparoscopic TAPP procedure using a large-pore PVDF mesh has the least effect compared to preoperative values.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20532568     DOI: 10.1007/s00464-010-1148-1

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  23 in total

1.  Testicular biopsy score count--a method for registration of spermatogenesis in human testes: normal values and results in 335 hypogonadal males.

Authors:  S G Johnsen
Journal:  Hormones       Date:  1970

2.  Functional and morphologic properties of a modified mesh for inguinal hernia repair.

Authors:  Karsten Junge; Uwe Klinge; Raphael Rosch; Bernd Klosterhalfen; Volker Schumpelick
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

3.  The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit.

Authors:  Christian Peiper; Karsten Junge; Uwe Klinge; Eva Strehlau; Carsten Krones; A Ottinger; Volker Schumpelick
Journal:  J Invest Surg       Date:  2005 Sep-Oct       Impact factor: 2.533

4.  Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes.

Authors:  Ruediger Horstmann; Matthias Hellwig; Claus Classen; Susanne Röttgermann; Daniel Palmes
Journal:  World J Surg       Date:  2006-09       Impact factor: 3.352

5.  Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair.

Authors:  P J O'Dwyer; A N Kingsnorth; R G Molloy; P K Small; B Lammers; G Horeyseck
Journal:  Br J Surg       Date:  2005-02       Impact factor: 6.939

6.  Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall.

Authors:  U Klinge; B Klosterhalfen; J Conze; W Limberg; B Obolenski; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

7.  European Hernia Society guidelines on the treatment of inguinal hernia in adult patients.

Authors:  M P Simons; T Aufenacker; M Bay-Nielsen; J L Bouillot; G Campanelli; J Conze; D de Lange; R Fortelny; T Heikkinen; A Kingsnorth; J Kukleta; S Morales-Conde; P Nordin; V Schumpelick; S Smedberg; M Smietanski; G Weber; M Miserez
Journal:  Hernia       Date:  2009-07-28       Impact factor: 4.739

8.  Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model.

Authors:  K Junge; M Binnebösel; R Rosch; A Ottinger; M Stumpf; G Mühlenbruch; V Schumpelick; U Klinge
Journal:  Hernia       Date:  2008-07-02       Impact factor: 4.739

9.  Can laparoscopic hernia repair alter function and volume of testis? Randomized clinical trial.

Authors:  Gökhan Akbulut; Mustafa Serteser; Aylin Yücel; Bumin Değirmenci; Sezgin Yilmaz; Coskun Polat; Osman San; Osman Nuri Dilek
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2003-12       Impact factor: 1.719

10.  Is testicular perfusion influenced during laparoscopic inguinal hernia surgery?

Authors:  S Ersin; U Aydin; O Makay; G Icoz; S Tamsel; M Sozbilen; R Killi
Journal:  Surg Endosc       Date:  2006-03-07       Impact factor: 4.584

View more
  8 in total

1.  Bilateral endoscopic total extraperitoneal (TEP) inguinal hernia repair does not induce obstructive azoospermia: data of a retrospective and prospective trial.

Authors:  S Skawran; D Weyhe; B Schmitz; O Belyaev; K H Bauer
Journal:  World J Surg       Date:  2011-07       Impact factor: 3.352

2.  Unilateral Lichtenstein tension-free mesh hernia repair and testicular perfusion: a prospective control study.

Authors:  J Aguilar-García; H A Cano-González; M A Martínez-Jiménez; F de la Rosa-Zapata; M Sánchez-Aguilar
Journal:  Hernia       Date:  2018-01-19       Impact factor: 4.739

3.  Outcomes from laparoscopic versus robotic mesh removal after inguinal hernia repair.

Authors:  Desmond Huynh; Xiaoxi Feng; Negin Fadaee; Nicholas Gonsalves; Shirin Towfigh
Journal:  Surg Endosc       Date:  2022-01-03       Impact factor: 3.453

Review 4.  [Hernia surgery: minimization of complications by selection of the "correct mesh"].

Authors:  U Klinge; D Weyhe
Journal:  Chirurg       Date:  2014-02       Impact factor: 0.955

5.  Role of orchiectomy in severe testicular pain after inguinal hernia surgery: audit of the Finnish Patient Insurance Centre.

Authors:  K Rönkä; J Vironen; H Kokki; T Liukkonen; H Paajanen
Journal:  Hernia       Date:  2013-08-09       Impact factor: 4.739

6.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

Review 7.  Hernioplasty and testicular perfusion.

Authors:  Osman Nuri Dilek
Journal:  Springerplus       Date:  2014-02-21

Review 8.  Fascinating history of groin hernias: Comprehensive recognition of anatomy, classic considerations for herniorrhaphy, and current controversies in hernioplasty.

Authors:  Tomohide Hori; Daiki Yasukawa
Journal:  World J Methodol       Date:  2021-07-20
  8 in total