Experimental study comparing meshes made of polypropylene, polypropylene + polyglactin and polypropylene + titanium: inflammatory cytokines, histological changes and morphometric analysis of collagen.

C G Pereira-Lucena1, R Artigiani-Neto, G J Lopes-Filho, C V G Frazao, A Goldenberg, D Matos, M M Linhares.   

Abstract

PURPOSE: Incisional hernia occurs in approximately 11% of all laparotomies. Changes in collagen have been closely implicated in its pathogenesis. The high recurrence rate (45-54%) after primary suture has stimulated the development of meshes. Currently, meshes are the biomaterials implant group most used in medicine. This study aims to compare the serum and tissue inflammatory responses and collagen deposition caused by meshes made of polypropylene, polypropylene + polyglactin and polypropylene + titanium.
METHODS: Thirty Wistar rats were divided into three groups. In group I, a high-density polypropylene mesh was positioned on the abdominal wall. In groups II and III, low-density meshes were used in associations with polyglactin and titanium, respectively. Immediately before the operation and on the first, third and fortieth postoperative days, pro-inflammatory cytokines were assayed. On the 40th postoperative day, the region of the inserted prosthesis was biopsied. The tissue inflammatory reaction was evaluated using a scale for objective scoring. For collagen, picrosirius was used with data reading using the Image Tool computer software.
RESULTS: Cytokines: there were no statistically significant differences between the groups. HISTOLOGY: on the 40th postoperative day in group I, there were fewer inflammatory tissue response and greater collagen deposition (P < 0.01). In group II, there were greater inflammatory tissue response and less collagen deposition (P < 0.01). Group III presented intermediate values between groups I and II.
CONCLUSIONS: There were no significant differences in cytokine levels between the groups in the present study. In the animals with the polypropylene + polyglactin mesh implant there was the most intense inflammatory process with lower tissue maturation and collagen deposition on the 40th postoperative day. The polypropylene mesh presented a less severe late inflammatory process, with greater tissue maturation and collagen deposition. The polypropylene + titanium mesh presented intermediate values between the others.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20072792     DOI: 10.1007/s10029-009-0621-z

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  28 in total

1.  Vypro II mesh in hernia repair: impact of polyglactin on long-term incorporation in rats.

Authors:  R Rosch; K Junge; R Quester; U Klinge; B Klosterhalfen; V Schumpelick
Journal:  Eur Surg Res       Date:  2003 Sep-Oct       Impact factor: 1.745

Review 2.  The lightweight and large porous mesh concept for hernia repair.

Authors:  Bernd Klosterhalfen; Karsten Junge; Uwe Klinge
Journal:  Expert Rev Med Devices       Date:  2005-01       Impact factor: 3.166

Review 3.  General principles of wound healing.

Authors:  M B Witte; A Barbul
Journal:  Surg Clin North Am       Date:  1997-06       Impact factor: 2.741

4.  Serum VEGF and b-FGF profiles after tension-free or conventional hernioplasty.

Authors:  Gaetano Di Vita; Rosalia Patti; Pietro D'Agostino; Francesco Arcoleo; Giuseppe Caruso; Matteo Arcara; Valentina Davì; Enrico Cillari
Journal:  Langenbecks Arch Surg       Date:  2005-09-23       Impact factor: 3.445

5.  [Effectiveness of hernioplasty with using a polypropylene mesh implant in treatment of postoperative ventral hernias].

Authors:  V M Sedov; S D Tarbaev; A A Gostevskoĭ; A S Gorelov
Journal:  Vestn Khir Im I I Grek       Date:  2005

6.  Functional and morphologic properties of a modified mesh for inguinal hernia repair.

Authors:  Karsten Junge; Uwe Klinge; Raphael Rosch; Bernd Klosterhalfen; Volker Schumpelick
Journal:  World J Surg       Date:  2002-09-26       Impact factor: 3.352

7.  Mesh incisional herniorrhaphy increases abdominal wall elastic properties: a mechanism for decreased hernia recurrences in comparison with suture repair.

Authors:  Derek A DuBay; Xue Wang; Belinda Adamson; William M Kuzon; Robert G Dennis; Michael G Franz
Journal:  Surgery       Date:  2006-07       Impact factor: 3.982

8.  Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair.

Authors:  P J O'Dwyer; A N Kingsnorth; R G Molloy; P K Small; B Lammers; G Horeyseck
Journal:  Br J Surg       Date:  2005-02       Impact factor: 6.939

9.  Factors affecting wound complications in repair of ventral hernias.

Authors:  T J White; M C Santos; J S Thompson
Journal:  Am Surg       Date:  1998-03       Impact factor: 0.688

10.  In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs.

Authors:  H Scheidbach; C Tamme; A Tannapfel; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2003-12-29       Impact factor: 4.584

View more
  10 in total

1.  Serum profile of pro- and anti-inflammatory cytokines in rats following implantation of low-temperature plasma-modified titanium plates.

Authors:  Uwe Walschus; Andreas Hoene; Maciej Patrzyk; Birgit Finke; Martin Polak; Silke Lucke; Barbara Nebe; Karsten Schroeder; Andreas Podbielski; Lutz Wilhelm; Michael Schlosser
Journal:  J Mater Sci Mater Med       Date:  2012-03-09       Impact factor: 3.896

2.  Inflammatory reaction and neotissue maturation in the early host tissue incorporation of polypropylene prostheses.

Authors:  G Pascual; M Rodríguez; S Sotomayor; B Pérez-Köhler; J M Bellón
Journal:  Hernia       Date:  2012-06-29       Impact factor: 4.739

3.  Effects of mesenchymal stem cell and fibroblast coating on immunogenic potential of prosthetic meshes in vitro.

Authors:  Yue Gao; David M Krpata; Cory N Criss; Lijia Liu; Natasza Posielski; Michael J Rosen; Yuri W Novitsky
Journal:  Surg Endosc       Date:  2014-06-28       Impact factor: 4.584

4.  Comparative study of shrinkage, inflammatory response and fibroplasia in heavyweight and lightweight meshes.

Authors:  L Zogbi; E N Trindade; M R M Trindade
Journal:  Hernia       Date:  2013-01-24       Impact factor: 4.739

5.  Early and late postoperative inflammatory and collagen deposition responses in three different meshes: an experimental study in rats.

Authors:  C G Pereira-lucena; R Artigiani Neto; D T de Rezende; G de J Lopes-Filho; D Matos; M M Linhares
Journal:  Hernia       Date:  2013-12-27       Impact factor: 4.739

Review 6.  What do we know about titanized polypropylene meshes? An evidence-based review of the literature.

Authors:  F Köckerling; C Schug-Pass
Journal:  Hernia       Date:  2013-11-20       Impact factor: 4.739

7.  Does a bilateral polypropylene mesh alter the duct deferens morphology, testicular size and testosterone levels? Experimental study in rats.

Authors:  Sérgio Henrique Bastos Damous; Luciana Lamarão Damous; Jocielle Dos Santos Miranda; Edna Frasson de Souza Montero; Cláudio Birolini; Edivaldo Massazo Utiyama
Journal:  Acta Cir Bras       Date:  2020-04-17       Impact factor: 1.388

8.  A preclinical evaluation of alternative synthetic biomaterials for fascial defect repair using a rat abdominal hernia model.

Authors:  Daniela Ulrich; Sharon L Edwards; Jacinta F White; Tommy Supit; John A M Ramshaw; Camden Lo; Anna Rosamilia; Jerome A Werkmeister; Caroline E Gargett
Journal:  PLoS One       Date:  2012-11-20       Impact factor: 3.240

9.  Immunological reaction and oxidative stress after light or heavy polypropylene mesh implantation in inguinal hernioplasty: A CONSORT-prospective, randomized, clinical trial.

Authors:  Marcello Donati; Giovanna Brancato; Giuseppe Grosso; Giovanni Li Volti; Giuseppina La Camera; Francesco Cardì; Francesco Basile; Angelo Donati
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889

10.  Scar quality examination comparing titanium-coated suture material and non-coated suture material on flap donor sites in reconstructive surgery.

Authors:  Laura K Berninghausen; Georg Osterhoff; Stefan Langer; Lukas H Kohler
Journal:  BMC Surg       Date:  2020-11-03       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.