Literature DB >> 17180568

Improving outcomes in hernia repair by the use of light meshes--a comparison of different implant constructions based on a critical appraisal of the literature.

Dirk Weyhe1, Orlin Belyaev, Christophe Müller, Kirsten Meurer, Karl-Heinz Bauer, Georgios Papapostolou, Waldemar Uhl.   

Abstract

BACKGROUND: Despite convincing advantages offered by meshes, their use in hernia surgery remains controversial because of fears concerning the long-term effects of their implantation. To improve biocompatibility, a large variety of newly developed light meshes has been introduced to the market. This overview of the literature aimed to establish whether absolute material reduction (g per implanted mesh), use of absorbable components, and coating by inert materials are evidence-based ways to improve biocompatibility of meshes.
METHOD: A review of the current English and German language literature on the outcome of groin und incisional hernia mesh repair was performed. Both basic research and clinical trials were used as sources of data. Meta-analyses and randomized controlled trials were given priority and were referred to whenever possible.
RESULTS: Operative technique was an independent prognostic factor for the clinical outcome. Mesh construction and composition as characterized by pore size and filament structure appeared to be more important determinants of foreign body reaction after implantation than absolute material reduction of 1 g or more per implant. No data exist about an oncogenic effect of alloplastic materials in humans, but disturbed fertility in animal studies remains an issue of concern and should be further investigated.
CONCLUSIONS: According to data from current randomized controlled trials and retrospective studies, light meshes seem to have some advantages with respect to postoperative pain and foreign body sensation. However, their use is associated with increased recurrence rates. Light meshes offer no advantages with respect to alleviating severe chronic groin pain. At the same time, experimental data reveal that material composition and mesh structure may significantly affect foreign body reaction.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17180568     DOI: 10.1007/s00268-006-0123-4

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  64 in total

Review 1.  The lightweight and large porous mesh concept for hernia repair.

Authors:  Bernd Klosterhalfen; Karsten Junge; Uwe Klinge
Journal:  Expert Rev Med Devices       Date:  2005-01       Impact factor: 3.166

2.  Porous methyl methacrylate as an implant material.

Authors:  D F Taylor; F B Smith
Journal:  J Biomed Mater Res       Date:  1972

3.  Quality assessment of 26,304 herniorrhaphies in Denmark: a prospective nationwide study.

Authors:  M Bay-Nielsen; H Kehlet; L Strand; J Malmstrøm; F H Andersen; P Wara; P Juul; T Callesen
Journal:  Lancet       Date:  2001-10-06       Impact factor: 79.321

Review 4.  Biomaterials for abdominal wall hernia surgery and principles of their applications.

Authors:  P K Amid; A G Shulman; I L Lichtenstein; M Hakakha
Journal:  Langenbecks Arch Chir       Date:  1994

5.  The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit.

Authors:  Christian Peiper; Karsten Junge; Uwe Klinge; Eva Strehlau; Carsten Krones; A Ottinger; Volker Schumpelick
Journal:  J Invest Surg       Date:  2005 Sep-Oct       Impact factor: 2.533

6.  Open mesh versus laparoscopic mesh repair of inguinal hernia.

Authors:  Leigh Neumayer; Anita Giobbie-Hurder; Olga Jonasson; Robert Fitzgibbons; Dorothy Dunlop; James Gibbs; Domenic Reda; William Henderson
Journal:  N Engl J Med       Date:  2004-04-25       Impact factor: 91.245

7.  Tumorigenicity of poly-L-lactide (PLLA) plates compared with medical-grade polyethylene.

Authors:  T Nakamura; Y Shimizu; N Okumura; T Matsui; S H Hyon; T Shimamoto
Journal:  J Biomed Mater Res       Date:  1994-01

8.  Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair.

Authors:  S Post; B Weiss; M Willer; T Neufang; D Lorenz
Journal:  Br J Surg       Date:  2004-01       Impact factor: 6.939

9.  Aspirin enhances thermotolerance in human erythroleukemic cells: an effect associated with the modulation of the heat shock response.

Authors:  C Amici; A Rossi; M G Santoro
Journal:  Cancer Res       Date:  1995-10-01       Impact factor: 12.701

10.  Tissue integration and biomechanical behaviour of contaminated experimental polypropylene and expanded polytetrafluoroethylene implants.

Authors:  J M Bellón; A García-Carranza; N García-Honduvilla; A Carrera-San Martín; J Buján
Journal:  Br J Surg       Date:  2004-04       Impact factor: 6.939

View more
  59 in total

1.  Novel technique of overlaying a poly-L: -lactic acid nanosheet for adhesion prophylaxis and fixation of intraperitoneal onlay polypropylene mesh in a rabbit model.

Authors:  Keiichi Fujino; Manabu Kinoshita; Akihiro Saitoh; Hidekazu Yano; Kahoko Nishikawa; Toshinori Fujie; Keiichi Iwaya; Minoru Kakihara; Shinji Takeoka; Daizoh Saitoh; Yuji Tanaka
Journal:  Surg Endosc       Date:  2011-06-03       Impact factor: 4.584

2.  Randomized controlled multicenter international clinical trial of self-gripping Parietex™ ProGrip™ polyester mesh versus lightweight polypropylene mesh in open inguinal hernia repair: interim results at 3 months.

Authors:  A Kingsnorth; M Gingell-Littlejohn; S Nienhuijs; S Schüle; P Appel; P Ziprin; A Eklund; M Miserez; S Smeds
Journal:  Hernia       Date:  2012-03-28       Impact factor: 4.739

3.  Inflammatory reaction and neotissue maturation in the early host tissue incorporation of polypropylene prostheses.

Authors:  G Pascual; M Rodríguez; S Sotomayor; B Pérez-Köhler; J M Bellón
Journal:  Hernia       Date:  2012-06-29       Impact factor: 4.739

4.  Mesh implants: An overview of crucial mesh parameters.

Authors:  Lei-Ming Zhu; Philipp Schuster; Uwe Klinge
Journal:  World J Gastrointest Surg       Date:  2015-10-27

5.  Retromuscular mesh repair of midline incisional hernia with polyester standard mesh: monocentric experience of 261 consecutive patients with a 5-year follow-up.

Authors:  Tigran Poghosyan; Nicolas Veyrie; Nicola Corigliano; Nada Helmy; Stephane Servajean; Jean-Luc Bouillot
Journal:  World J Surg       Date:  2012-04       Impact factor: 3.352

6.  Open inguinal hernia repair with the use of a polyglycolic acid-trimethylene carbonate absorbable mesh: a pilot study.

Authors:  M Efthimiou; D Symeonidis; G Koukoulis; K Tepetes; D Zacharoulis; G Tzovaras
Journal:  Hernia       Date:  2010-12-22       Impact factor: 4.739

7.  Improving outcomes in hernia repair by the use of light meshes.

Authors:  Andrew Kingsnorth
Journal:  World J Surg       Date:  2007-05-30       Impact factor: 3.352

8.  The risk of communicating TEP-related infertility risk is an opportunity and not a "Cinderella concern" any more.

Authors:  Brij B Agarwal; Bijendra K Sinha; Krishan C Mahajan
Journal:  Surg Endosc       Date:  2008-04-10       Impact factor: 4.584

9.  Comparison of complete versus partial mesh removal for the treatment of chronic mesh infection after abdominal wall hernia repair.

Authors:  S Levy; D Moszkowicz; T Poghosyan; A Beauchet; M -M Chandeze; K Vychnevskaia; F Peschaud; J -L Bouillot
Journal:  Hernia       Date:  2018-05-23       Impact factor: 4.739

10.  Mesh fixation with fibrin glue (Tissucol/Tisseel) in hernia repair dependent on the mesh structure--is there an optimum fibrin-mesh combination?--investigations on a biomechanical model.

Authors:  Christine Schug-Pass; Hans Lippert; Ferdinand Köckerling
Journal:  Langenbecks Arch Surg       Date:  2009-01-31       Impact factor: 3.445

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.