Dose classification scheme for computed tomography of the paranasal sinuses.

A Hojreh1, C Czerny, F Kainberger.   

Abstract

PURPOSE: The purpose of this study was to define objective and reproducible standards for the quality of CT images as a function of radiation doses and therapeutic validity.
MATERIALS AND METHODS: CT images of the paranasal sinuses of 145 patients (77 female, 68 male; 5-83 years old; mean age, 39.9 years) were classified both subjectively (with a view toward their validity for the planning of functional endoscopic sinus surgery, FESS) and objectively by defining the pixel noise (the standard deviation, STD, of the CT number) in a homogeneous region of interest (ROI), centered on the M. masseter and on the frontal lobe. These measurements were then compared to measurements obtained from scan images of a water-filled Perspex phantom.
RESULTS: The pixel noise measured in the phantom images was nearly identical to the respective values on the M. masseter on the patient images. The use of an edge-enhancing reconstruction algorithm and low-dose protocols, with a pixel noise amounting to 70-90 Hounsfield Units (HU), are indicated for children, chronic sinusitis, and septum deviation, while standard protocols, with a pixel noise of 50-70 HU, are recommended for the preoperative planning and postoperative control of FESS. The pixel noise for high-dose protocols is less than 50 HU; nonetheless, such protocols should generally be avoided.
CONCLUSION: The pixel noise measured in a water-filled Perspex phantom is indicative of the clinical potential and image quality of paranasal sinus CT scans. Alternatively, the M. masseter can be chosen as an ROI to measure the pixel noise in order to obtain a rough estimate of the image quality or radiation dose class.

Entities:  

Mesh:

Year:  2005        PMID: 16168261     DOI: 10.1016/j.ejrad.2004.12.006

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  13 in total

1.  Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm.

Authors:  Lars-Arne Schaafs; Julian Lenk; Bernd Hamm; Stefan Markus Niehues
Journal:  Dentomaxillofac Radiol       Date:  2016-07-15       Impact factor: 2.419

2.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

3.  Nasal endoscopy: an adjunct to patient selection for preoperative low-dose CT examination in chronic rhinosinusitis.

Authors:  Marcin Fraczek; Maciej Guzinski; Monika Morawska-Kochman; Kamil H Nelke; Tomasz Krecicki
Journal:  Dentomaxillofac Radiol       Date:  2016-10-17       Impact factor: 2.419

4.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

5.  Radiation dose reduction in parasinus CT by spectral shaping.

Authors:  Matthias S May; Michael Brand; Michael M Lell; Martin Sedlmair; Thomas Allmendinger; Michael Uder; Wolfgang Wuest
Journal:  Neuroradiology       Date:  2017-01-16       Impact factor: 2.804

6.  [Dose optimization in CT examination of children].

Authors:  A Hojreh; H Prosch
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

7.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

Review 8.  [Postoperative imaging of paranasal sinuses].

Authors:  S Nemec; M Formanek; C Czerny
Journal:  Radiologe       Date:  2007-07       Impact factor: 0.635

9.  A comparison between low-dose and standard-dose non-contrasted multidetector CT scanning of the paranasal sinuses.

Authors:  Sy Lam; Si Bux; G Kumar; Kh Ng; Af Hussain
Journal:  Biomed Imaging Interv J       Date:  2009-07-01

10.  The CT and MRI observations of small cell neuroendocrine carcinoma in paranasal sinuses.

Authors:  Qingqiang Zhu; Wenrong Zhu; Jingtao Wu; Hongying Zhang
Journal:  World J Surg Oncol       Date:  2015-02-15       Impact factor: 2.754

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.