Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

C Schmidt1, G Theilmeier, H Van Aken, P Korsmeier, S P Wirtz, E Berendes, A Hoffmeier, A Meissner.   

Abstract

BACKGROUND: Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal Doppler echocardiographic quantification of CO (TOE-CO) has emerged as a reliable method, the purpose of this study was to determine the limits of agreement between CO estimations using EV (EV-CO) and TOE-CO.
METHODS: Standard ECG electrodes were used for non-invasive EV-CO measurements. These were placed on 37 patients scheduled for coronary artery surgery necessitating transoesophageal echocardiography monitoring. Simultaneous EV-CO and TOE-CO measurements were recorded after induction of anaesthesia. EV-CO was calculated using the Bernstein-Osypka equation. TOE-CO was measured across the aortic valve using continuous-wave Doppler echocardiography and a triangular orifice model.
RESULTS: A significant high correlation was found between the TOE-CO and the EV-CO measurements (r2=0.86). Data were related linearly. The slope of the line (1.10 (se 0.07)) was not significantly different from unity, and the point at which it intersected the ordinate (-0.46 (0.32) litre min(-1)) was not significantly different from zero. Bland-Altman analysis revealed a bias of 0.18 litre min(-1) with narrow limits of agreement (-0.99 to 1.36 litre min(-1)).
CONCLUSIONS: The agreement between EV-CO and TOE-CO is clinically acceptable, and these two techniques can be used interchangeably.

Entities:  

Mesh:

Year:  2005        PMID: 16155037     DOI: 10.1093/bja/aei224

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  34 in total

1.  Can a NICO monitor substitute for thermodilution to measure cardiac output in patients with coexisting tricuspid regurgitation?

Authors:  Naka Imakiire; Takeshi Omae; Akira Matsunaga; Ryuzo Sakata; Yuichi Kanmura
Journal:  J Anesth       Date:  2010-05-19       Impact factor: 2.078

2.  A validation study of electrical cardiometry in pregnant patients using transthoracic echocardiography as the reference standard.

Authors:  Erin Martin; Adanna Anyikam; Jerasimos Ballas; Kristen Buono; Kristin Mantell; Thao Huynh-Covey; Thomas Archer
Journal:  J Clin Monit Comput       Date:  2015-09-24       Impact factor: 2.502

3.  Bernstein-Osypka stroke volume equation for impedance cardiography: citation correction.

Authors:  Donald P Bernstein
Journal:  Intensive Care Med       Date:  2007-03-27       Impact factor: 17.440

4.  The basic pacing rate in CRT patients: the higher the better?

Authors:  Frederik Voss; Ruediger Becker; Melanie Hauck; Hugo A Katus; Alexander Bauer
Journal:  Clin Res Cardiol       Date:  2009-02-13       Impact factor: 5.460

5.  A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Ursula Hoffmann; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  Clin Res Cardiol       Date:  2011-07-01       Impact factor: 5.460

6.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

7.  Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.

Authors:  Frederik Trinkmann; Manuel Berger; Christina Doesch; Theano Papavassiliu; Stefan O Schoenberg; Martin Borggrefe; Jens J Kaden; Joachim Saur
Journal:  J Clin Monit Comput       Date:  2015-06-27       Impact factor: 2.502

8.  Influence of patent ductus arteriosus and ventilators on electrical velocimetry for measuring cardiac output in very-low/low birth weight infants.

Authors:  T Torigoe; S Sato; Y Nagayama; T Sato; H Yamazaki
Journal:  J Perinatol       Date:  2015-01-29       Impact factor: 2.521

9.  Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.

Authors:  Martin Ernst Blohm; Jana Hartwich; Denise Obrecht; Jan Felix Kersten; Dominique Singer
Journal:  J Clin Monit Comput       Date:  2016-04-12       Impact factor: 2.502

10.  Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry.

Authors:  Stephan Schubert; Thomas Schmitz; Markus Weiss; Nicole Nagdyman; Michael Huebler; Vladimir Alexi-Meskishvili; Felix Berger; Brigitte Stiller
Journal:  J Clin Monit Comput       Date:  2008-07-30       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.