Literature DB >> 26403606

A validation study of electrical cardiometry in pregnant patients using transthoracic echocardiography as the reference standard.

Erin Martin1, Adanna Anyikam2, Jerasimos Ballas2,3, Kristen Buono2,4, Kristin Mantell2, Thao Huynh-Covey2, Thomas Archer2.   

Abstract

To validate electrical cardiometry (EC) in pregnant patients using transthoracic echocardiography (TTE) as the reference standard. To improve EC accuracy via a one-time, measurement of left ventricular outflow tract (LVOT) diameter. 44 non-laboring, resting women with singleton, viable pregnancies underwent simultaneous EC and TTE measurements. Data were analyzed using Bland-Altman analysis. Entry multiple regression with stepwise elimination was used to develop a model for improved prediction of stroke volume by TTE (SVTTE) using EC. Bootstrapping and an 11-fold cross validation were used to test the model. Heart rate by TTE and EC had a mean bias of 3.3 beats/min and mean percentage error of 10.7 %. Envelope time and left ventricular ejection time had a mean bias of -4.9 ms and mean percentage error 12.7 %. Stroke volumes by the two techniques had a mean bias of 15.6 mL and mean percentage error of 43.7 %. A model, SVEC_Modified, predicting SVTTE was developed using LVOT area, stroke volume by electrical cardiometry and weight. SVTTE and SVEC_Modified had a mean bias of -0.83 mL and mean percentage error of 22 %. EC accurately measures heart rate and duration of systole when compared with TTE. Stroke volume measurements correlate but have a high bias and percentage error. Knowledge of LVOT area, by a one-time, measurement with TTE, could improve prediction of stroke volume by EC.

Entities:  

Keywords:  Cardiac output; Electrical cardiometry; Impedance cardiography

Mesh:

Year:  2015        PMID: 26403606     DOI: 10.1007/s10877-015-9771-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  27 in total

1.  Continuous hemodynamic monitoring by esophageal Doppler.

Authors:  M Singer; J Clarke; E D Bennett
Journal:  Crit Care Med       Date:  1989-05       Impact factor: 7.598

2.  Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.

Authors:  C Schmidt; G Theilmeier; H Van Aken; P Korsmeier; S P Wirtz; E Berendes; A Hoffmeier; A Meissner
Journal:  Br J Anaesth       Date:  2005-09-09       Impact factor: 9.166

3.  Noninvasive optimization of left ventricular filling using esophageal Doppler.

Authors:  M Singer; E D Bennett
Journal:  Crit Care Med       Date:  1991-09       Impact factor: 7.598

4.  Noninvasive maternal stroke volume and cardiac output determinations by pulsed Doppler echocardiography.

Authors:  W Lee; R Rokey; D B Cotton
Journal:  Am J Obstet Gynecol       Date:  1988-03       Impact factor: 8.661

5.  Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets.

Authors:  Wilhelm Alexander Osthaus; Dirk Huber; Carsten Beck; Michael Winterhalter; Dietmar Boethig; Armin Wessel; Robert Sümpelmann
Journal:  Paediatr Anaesth       Date:  2007-08       Impact factor: 2.556

6.  Rapid echocardiographic assessment of left and right heart hemodynamics in critically ill obstetric patients.

Authors:  M A Belfort; R Rokey; G R Saade; K J Moise
Journal:  Am J Obstet Gynecol       Date:  1994-10       Impact factor: 8.661

7.  Value of two-dimensional echocardiography for determining the basis of hemodynamic compromise in critically ill patients: a prospective study.

Authors:  S Kaul; A A Stratienko; S G Pollock; M A Marieb; M W Keller; P J Sabia
Journal:  J Am Soc Echocardiogr       Date:  1994 Nov-Dec       Impact factor: 5.251

8.  Comparison of echocardiographic assessment of cardiac hemodynamics in the intensive care unit with right-sided cardiac catheterization.

Authors:  S F Dabaghi; R Rokey; J M Rivera; W I Saliba; P A Majid
Journal:  Am J Cardiol       Date:  1995-08-15       Impact factor: 2.778

Review 9.  Pulmonary artery catheters for adult patients in intensive care.

Authors:  Sujanthy S Rajaram; Nayan K Desai; Ankur Kalra; Mithil Gajera; Susan K Cavanaugh; William Brampton; Duncan Young; Sheila Harvey; Kathy Rowan
Journal:  Cochrane Database Syst Rev       Date:  2013-02-28

10.  Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography.

Authors:  J Burlingame; P Ohana; M Aaronoff; T Seto
Journal:  J Perinatol       Date:  2013-05-16       Impact factor: 2.521

View more
  5 in total

1.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

2.  Validation of electrical velocimetry in resuscitation of patients undergoing liver transplantation. Observational study.

Authors:  Ahmed M Mukhtar; Mohamed Elayashy; Amr H Sayed; Gihan M Obaya; Akram A Eladawy; Mai A Ali; Hisham M Dahab; Dina Z Khalaf; Mostafa A Mohamed; Amr H Elfouly; Gad M Behairy; Amr A Abdelaal
Journal:  J Clin Monit Comput       Date:  2019-04-19       Impact factor: 2.502

3.  Effect of patent ductus arteriosus and patent foramen ovale on left ventricular stroke volume measurement by electrical velocimetry in comparison to transthoracic echocardiography in neonates.

Authors:  Martin Ernst Blohm; Jana Hartwich; Denise Obrecht; Jan Felix Kersten; Dominique Singer
Journal:  J Clin Monit Comput       Date:  2016-04-12       Impact factor: 2.502

4.  The accuracy of electrical cardiometry for the noninvasive determination of cardiac output before and after lung surgeries compared to transthoracic echocardiography.

Authors:  Ahmed S Elgebaly; Atteia G Anwar; Sameh M Fathy; Ayman Sallam; Yaser Elbarbary
Journal:  Ann Card Anaesth       Date:  2020 Jul-Sep

5.  Electrocardiometry for Hemodynamic Categorization and Assessment of Fluid Responsiveness in Pediatric Septic Shock: A Pilot Observational Study.

Authors:  Swathi S Rao; A V Lalitha; Mounika Reddy; Santu Ghosh
Journal:  Indian J Crit Care Med       Date:  2021-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.