Abstract

BACKGROUND: Continuous and non-invasive measurement of cardiac output (CO) may contribute helpful information to the care and treatment of the critically ill pediatric patient. Different methods are available but their clinical verification is still a major problem. AIM: Comparison of reliability and safety of two continuous non-invasive methods with transthoracic echocardiography (TTE) for CO measurement: electric velocimetry technique (EV, Aesculon) and transesophageal Doppler (TED, CardioQP). METHODS/MATERIAL: In 26 infants and children who had undergone corrective cardiac surgery at a median age of 3.5 (1-17) years CO and stroke volume (SV) were obtained by EV, TED and TTE. Each patient had five measurements on the first day after surgery, during mechanical ventilation and sedation.
RESULTS: Values for CO and SV from TED and EV correlated well with those of TTE (r = 0.85 and r = 0.88), but mean values were significantly lower than the values of TTE for TED (P = 0.02) and EV (P = 0.001). According to Bland-Altman analysis, bias was 0.36 l/min with a precision of 1.67 l/min for TED vs. TTE and 0.87 l/min (bias) with a precision of 3.26 l/min for EV vs. TTE. No severe adverse events were observed and the handling of both systems was easy in the sedated child.
CONCLUSIONS: In pediatric patients non-invasive measurement of CO and SV with TED and EV is useful for continuous monitoring after heart surgery. Both new methods seem to underestimate cardiac output in terms of absolute values. However, TED shows tolerable bias and precision and may be helpful for continuous CO monitoring in a deeply sedated and ventilated pediatric patient, e.g. in the operating room or intensive care unit.

Entities:  

Mesh:

Year:  2008        PMID: 18665449     DOI: 10.1007/s10877-008-9133-0

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  55 in total

1.  The hemodynamic effects of pediatric caudal anesthesia assessed by esophageal Doppler.

Authors:  Eric Larousse; Karim Asehnoune; Bruno Dartayet; Pierre Albaladejo; Anne-Marie Dubousset; Frédéric Gauthier; Dan Benhamou
Journal:  Anesth Analg       Date:  2002-05       Impact factor: 5.108

2.  Clinical assessment of cardiac performance in infants and children following cardiac surgery.

Authors:  Jonathan R Egan; Marino Festa; Andrew D Cole; Graham R Nunn; Jonathan Gillis; David S Winlaw
Journal:  Intensive Care Med       Date:  2005-02-15       Impact factor: 17.440

3.  Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: comparison with thermodilution.

Authors:  L E Young; K J Blissitt; D H Bartram; R E Clutton; V Molony; R S Jones
Journal:  Br J Anaesth       Date:  1996-12       Impact factor: 9.166

4.  Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution.

Authors:  P Estagnasié; K Djedaini; L Mier; F Coste; D Dreyfuss
Journal:  Intensive Care Med       Date:  1997-07       Impact factor: 17.440

5.  [Non-invasive versus invasive cardiovascular monitoring. Determination of stroke volume and pulmonary hydration using a new bioimpedance monitor].

Authors:  J Boldt; D Kling; A Thiel; G Hempelmann
Journal:  Anaesthesist       Date:  1988-04       Impact factor: 1.041

6.  Geometric method for measuring body surface area: a height-weight formula validated in infants, children, and adults.

Authors:  G B Haycock; G J Schwartz; D H Wisotsky
Journal:  J Pediatr       Date:  1978-07       Impact factor: 4.406

7.  Improving agreement between thoracic bioimpedance and dye dilution cardiac output estimation in children.

Authors:  A J O'Connell; J Tibballs; M Coulthard
Journal:  Anaesth Intensive Care       Date:  1991-08       Impact factor: 1.669

8.  Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets.

Authors:  Wilhelm Alexander Osthaus; Dirk Huber; Carsten Beck; Michael Winterhalter; Dietmar Boethig; Armin Wessel; Robert Sümpelmann
Journal:  Paediatr Anaesth       Date:  2007-08       Impact factor: 2.556

Review 9.  Monitoring cardiac function in intensive care.

Authors:  S M Tibby; I A Murdoch
Journal:  Arch Dis Child       Date:  2003-01       Impact factor: 3.791

10.  Comparison of cardiac output measurements by thermodilution and thoracic electrical bioimpedance in critically ill versus non-critically ill patients.

Authors:  S Weiss; E Calloway; J Cairo; W Granger; J Winslow
Journal:  Am J Emerg Med       Date:  1995-11       Impact factor: 2.469

View more
  21 in total

1.  Changes in cardiac output and stroke volume as measured by non-invasive CO monitoring in infants with RSV bronchiolitis.

Authors:  Julie Caplow; Sarah C McBride; Garry M Steil; Jackson Wong
Journal:  J Clin Monit Comput       Date:  2012-04-24       Impact factor: 2.502

Review 2.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

3.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

4.  Propofol effect on cerebral oxygenation in children with congenital heart disease.

Authors:  Thilo Fleck; Stephan Schubert; Peter Ewert; Brigitte Stiller; Nicole Nagdyman; Felix Berger
Journal:  Pediatr Cardiol       Date:  2014-10-14       Impact factor: 1.655

5.  Hemodynamic alterations recorded by electrical cardiometry during ligation of ductus arteriosus in preterm infants.

Authors:  Reyin Lien; Kai-Hsiang Hsu; Jaw-Ji Chu; Yu-Sheng Chang
Journal:  Eur J Pediatr       Date:  2014-10-15       Impact factor: 3.183

6.  Comparison of cardiovascular parameter estimation methods using swine data.

Authors:  Tatsuya Arai; Kichang Lee; Richard J Cohen
Journal:  J Clin Monit Comput       Date:  2019-05-18       Impact factor: 2.502

7.  Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates.

Authors:  A Boet; G Jourdain; S Demontoux; D De Luca
Journal:  J Perinatol       Date:  2016-04-21       Impact factor: 2.521

8.  Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry.

Authors:  K-H Hsu; T-W Wu; Y-C Wang; W-H Lim; C-C Lee; R Lien
Journal:  J Perinatol       Date:  2016-02-18       Impact factor: 2.521

9.  Cardiac parameters in children recovered from acute illness as measured by electrical cardiometry and comparisons to the literature.

Authors:  Jackson Wong; Michael S D Agus; Garry M Steil
Journal:  J Clin Monit Comput       Date:  2012-10-06       Impact factor: 2.502

10.  Reference values of aortic flow velocity integral in 1193 healthy infants, children, and adolescents to quickly estimate cardiac stroke volume.

Authors:  Christiane Pees; Eva Glagau; Jakob Hauser; Ina Michel-Behnke
Journal:  Pediatr Cardiol       Date:  2013-01-24       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.