[Intraoperative three-dimensional imaging with an isocentric mobile C-arm at the wrist].

R Meier1, M Kfuri, J Geerling, T Hüfner, H Krimmer, C Krettek.   

Abstract

In addition to conventional radiological C-arm image amplifiers used for intraoperative imaging, now a new mobile C-arm image amplifier with an option for three dimensional imaging (Iso-C 3D) is available to visualize reduction of fractures and position of implants. In a wrist-model three titanium pins were placed and three holes of different length were drilled. Distances between the pins and the depths of the drilled holes were calculated in conventional computer tomographic scans and Iso-C 3D scans in perpendicular, 30 degree and 90 degree position of the gantry and compared to actual distances and depths. There were no significant differences between the actual measured distances and those measured by CT scans and Iso-C 3D scans. Furthermore, gantry position had no significant effect upon the results. Iso-C 3D scans are as reliable as conventional CT scans for intraoperative controlling of implant positioning.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16149034     DOI: 10.1055/s-2004-830563

Source DB:  PubMed          Journal:  Handchir Mikrochir Plast Chir        ISSN: 0722-1819            Impact factor:   1.018


  6 in total

1.  [Handling modern imaging procedures in a high-tech operating room].

Authors:  T Hüfner; M Citak; J Imrecke; C Krettek; T Stübig
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

2.  [Radiological procedures in the traumatised wrist].

Authors:  R Meier; H Jansen; M Uhl
Journal:  Orthopade       Date:  2010-08       Impact factor: 1.087

3.  [Cost-benefit analysis of intraoperative 3D imaging].

Authors:  T Hüfner; T Stübig; T Gösling; D Kendoff; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

4.  [Radiological procedures in the traumatised wrist].

Authors:  R Meier; H Jansen; M Uhl
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

5.  [Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

Authors:  S Wirth; E Euler; D Kotsianos-Hermle; M Treitl; U Linsenmaier; K-J Pfeifer; M Reiser; W Mutschler
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

6.  [The isocentric C-arm. Visualization of fracture reduction and screw position in the radius].

Authors:  R Meier; J Geerling; T Hüfner; M Kfuri; C Krettek
Journal:  Unfallchirurg       Date:  2011-07       Impact factor: 1.000

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.