Operating rooms are the central unit in the hospital network in trauma centers. In this area, high costs but also high revenues are generated. Modern operating theater concepts as an integrated model have been offered by different companies since the early 2000s. Our hypothesis is that integrative concepts for operating rooms, in addition to improved operating room ergonomics, have the potential for measurable time and cost savings. In our clinic, an integrated operating room concept (I-Suite, Stryker, Duisburg) was implemented after analysis of the problems. In addition to the ceiling-mounted arrangement, the system includes an endoscopy unit, a navigation system, and a voice control system. In the first 6 months (9/2005 to 2/2006), 112 procedures were performed in the integrated operating room: 34 total knee arthroplasties, 12 endoscopic spine surgeries, and 66 inpatient arthroscopic procedures (28 shoulder and 38 knee reconstructions). The analysis showed a daily saving of 22-45 min, corresponding to 15-30% of the daily changeover times, calculated to account for potential savings in the internal cost allocation of 225-450 EUR. A commercial operating room concept was evaluated in a pilot phase in terms of hard data, including time and cost factors. Besides the described effects further savings might be achieved through the effective use of voice control and the benefit of the sterile handle on the navigation camera, since waiting times for an additional nurse are minimized. The time of the procedure of intraoperative imaging is also reduced due to the ceiling-mounted concept, as the C-arm can be moved freely in the operating theater without hindering cables. By these measures and ensuing improved efficiency, the initial high costs for the implementation of the system may be cushioned over time.

Entities:  

Mesh:

Year:  2012        PMID: 22367523     DOI: 10.1007/s00113-012-2181-4

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  20 in total

1.  [The PACS concept of the University of Regensburg].

Authors:  R Fründ; J Techert; M Strotzer; W Börner; A Tsakpinis; S Feuerbach
Journal:  Rofo       Date:  2001-04

2.  [Limits of CT-based computer navigation in spinal surgery].

Authors:  F Gebhard; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2000-08       Impact factor: 1.000

3.  The multifunctional therapy room of the future: image guidance, interdisciplinarity, integration and impact on patient pathways.

Authors:  A L Jacob; P Regazzoni; W Steinbrich; P Messmer
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

4.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

5.  [Total knee arthroplasty--navigation as the standard].

Authors:  L Kinzl; F Gebhard; P Keppler
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

6.  [Intraoperative three-dimensional imaging with an isocentric mobile C-arm at the wrist].

Authors:  R Meier; M Kfuri; J Geerling; T Hüfner; H Krimmer; C Krettek
Journal:  Handchir Mikrochir Plast Chir       Date:  2005-08       Impact factor: 1.018

7.  [Cost-benefit analysis of intraoperative 3D imaging].

Authors:  T Hüfner; T Stübig; T Gösling; D Kendoff; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2007-01       Impact factor: 1.000

8.  Role of navigation in total hip arthroplasty.

Authors:  Todd C Kelley; Michael L Swank
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

9.  [Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system].

Authors:  P A Grützner; E Rose; B Vock; F Holz; L P Nolte; A Wentzensen
Journal:  Unfallchirurg       Date:  2002-03       Impact factor: 1.000

Review 10.  Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.

Authors:  Ioannis D Gelalis; Nikolaos K Paschos; Emilios E Pakos; Angelos N Politis; Christina M Arnaoutoglou; Athanasios C Karageorgos; Avraam Ploumis; Theodoros A Xenakis
Journal:  Eur Spine J       Date:  2011-09-07       Impact factor: 3.134

View more
  4 in total

1.  Current state of computer-assisted trauma surgery.

Authors:  Barbara M Dirhold; Mustafa Citak; Hesham Al-Khateeb; Carl Haasper; Daniel Kendoff; Christian Krettek; Musa Citak
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

Review 2.  [Intraoperative 3D imaging in spinal surgery].

Authors:  O Gonschorek; S Hauck; V Bühren
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

3.  Implementation of integrated operating rooms: how much time is saved and how do medical staff experience the upgrading? A mixed methods study in Denmark.

Authors:  Kathrine Carstensen; Emma Kejser Jensen; Mads Lænsø Madsen; Anne Marie Ladehoff Thomsen; Claus Løvschall; Nasrin Tayyari Dehbarez; Bettina Wulff Risør
Journal:  BMJ Open       Date:  2020-07-29       Impact factor: 2.692

4.  Role of Intelligent Management Systems in Surgical Punctuality and Quality of Care.

Authors:  Gendi Li; Shenhui Huang
Journal:  Comput Intell Neurosci       Date:  2022-10-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.