Literature DB >> 16140814

Cemented rotating-platform total knee replacement. a concise follow-up, at a minimum of fifteen years, of a previous report.

John J Callaghan1, Michael R O'Rourke, Michael F Iossi, Steve S Liu, Devon D Goetz, David A Vittetoe, Patrick M Sullivan, Richard C Johnston.   

Abstract

We previously evaluated 119 consecutive total knee arthroplasties that were performed in eighty-six patients with use of the cemented LCS (low contact stress) rotating-platform system with an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years (range, thirty-seven to eighty-eight years). The purpose of this study was to report the updated results at a minimum follow-up of fifteen years. Thirty-seven patients (fifty-three knees) were living, and no patient was lost to follow-up. No knee was revised because of loosening, osteolysis, or wear. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. Osteolysis was present in three knees. No knee had radiographic signs of component loosening, and there were no dislocated bearings. The average range of motion was from 1 degrees of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49, respectively, at the preoperative evaluation and 85 and 58 at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of fifteen years.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16140814     DOI: 10.2106/JBJS.D.03039

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  18 in total

1.  No early tibial tray loosening after surface cementing technique in mobile-bearing TKA.

Authors:  Roberto Rossi; Matteo Bruzzone; Davide Edoardo Bonasia; Andrea Ferro; Filippo Castoldi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

2.  Staged bilateral mobile-bearing and fixed-bearing total knee arthroplasty in the same patients: a prospective comparison of a posterior-stabilized prosthesis.

Authors:  Masahiro Hasegawa; Akihiro Sudo; Atsumasa Uchida
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-20       Impact factor: 4.342

3.  Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric study.

Authors:  Frédéric Borrione; Paul Bonnevialle; Christian Mabit; Olivier Guingand; Denis Bertin; François Bonnomet; Christophe Denis; Gilles Gagna
Journal:  Int Orthop       Date:  2011-03-02       Impact factor: 3.075

4.  Osteolysis in well-functioning fixed- and mobile-bearing TKAs in younger patients.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2010-04-01       Impact factor: 4.176

5.  In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions.

Authors:  Kazuma Futai; Tetsuya Tomita; Takaharu Yamazaki; Masashi Tamaki; Hideki Yoshikawa; Kazuomi Sugamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-16       Impact factor: 4.342

6.  Routine surveillance of modular PFC TKA shows increasing failures after 10 years.

Authors:  Andrew S Malin; John J Callaghan; Kevin J Bozic; Steve S Liu; Devon D Goetz; Nicholas Sullivan; Scott S Kelley
Journal:  Clin Orthop Relat Res       Date:  2010-03-19       Impact factor: 4.176

7.  Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-20       Impact factor: 4.342

8.  NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study.

Authors:  Roberto Rossi; Andrea Ferro; Matteo Bruzzone; Davide Edoardo Bonasia; Giacomo Garzaro; Filippo Castoldi
Journal:  Chir Organi Mov       Date:  2009-04-29

9.  Lateral retinacular release rates in mobile- versus fixed-bearing TKA.

Authors:  Charles C Yang; Lee A McFadden; Douglas A Dennis; Raymond H Kim; Adrija Sharma
Journal:  Clin Orthop Relat Res       Date:  2008-08-16       Impact factor: 4.176

10.  What can be learned from minimum 20-year followup studies of knee arthroplasty?

Authors:  John J Callaghan; Christopher T Martin; Yubo Gao; Andrew J Pugely; Steve S Liu; Devon D Goetz; Scott S Kelley; Richard C Johnston
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.