Literature DB >> 19711003

NexGen LPS rotating platform total knee arthroplasty: medium-term results of a prospective study.

Roberto Rossi1, Andrea Ferro, Matteo Bruzzone, Davide Edoardo Bonasia, Giacomo Garzaro, Filippo Castoldi.   

Abstract

The purpose of this study is to present midterm results of NexGen LPS (Zimmer, Warsaw) rotating platform total knee arthroplasty. A prospective consecutive series of 50 primary rotating platform total knee replacements in 43 patients were clinically and radiographically evaluated at a mean follow-up of 46.4 (range 30-78) months. There were 12 men (30%) and 31 women (70%) with an average age of 72.3 years (range 55-85). All implants were cruciate-substituting and cemented. Patients were assessed using the Knee Society Clinical Rating System and the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Pre-operatively, the mean knee score was 50.7 points (SD 15.1) and the mean function score was 40.5 points (SD 22.7). Post-operatively the mean knee score was 91.6 (SD 6.5) and the mean function score was 85.9 (SD 17.4). No sign of component loosening or osteolysis could be identified. The NexGen LPS rotating platform total knee replacement design provided excellent mid-term clinical and radiographical results.

Entities:  

Mesh:

Year:  2009        PMID: 19711003     DOI: 10.1007/s12306-009-0027-1

Source DB:  PubMed          Journal:  Chir Organi Mov        ISSN: 0009-4749


  45 in total

1.  Posterior stabilized prosthesis. Results after follow-up of nine to twelve years.

Authors:  S H Stern; J N Insall
Journal:  J Bone Joint Surg Am       Date:  1992-08       Impact factor: 5.284

2.  Posterior cruciate condylar total knee arthroplasty. Average 11-year follow-up evaluation.

Authors:  D A Dennis; M L Clayton; S O'Donnell; R P Mack; E A Stringer
Journal:  Clin Orthop Relat Res       Date:  1992-08       Impact factor: 4.176

3.  The total condylar prosthesis. 10- to 12-year results of a cemented knee replacement.

Authors:  K G Vince; J N Insall; M A Kelly
Journal:  J Bone Joint Surg Br       Date:  1989-11

4.  Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period.

Authors:  C S Ranawat; O Boachie-Adjei
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

5.  The problem of surface damage in polyethylene total knee components.

Authors:  T M Wright; D L Bartel
Journal:  Clin Orthop Relat Res       Date:  1986-04       Impact factor: 4.176

6.  Failure of the polyethylene bearing surface of a total knee replacement within four years. A case report.

Authors:  G A Engh
Journal:  J Bone Joint Surg Am       Date:  1988-08       Impact factor: 5.284

7.  Long-term followup of the Miller-Galante total knee replacement.

Authors:  R A Berger; A G Rosenberg; R M Barden; M B Sheinkop; J J Jacobs; J O Galante
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

8.  Tibial insert undersurface as a contributing source of polyethylene wear debris.

Authors:  R C Wasielewski; N Parks; I Williams; H Surprenant; J P Collier; G Engh
Journal:  Clin Orthop Relat Res       Date:  1997-12       Impact factor: 4.176

9.  Impact of modern technique on long-term results of total condylar knee arthroplasty.

Authors:  C S Ranawat; W F Flynn; R G Deshmukh
Journal:  Clin Orthop Relat Res       Date:  1994-12       Impact factor: 4.176

10.  Patient outcomes following tricompartmental total knee replacement. A meta-analysis.

Authors:  C M Callahan; B G Drake; D A Heck; R S Dittus
Journal:  JAMA       Date:  1994-05-04       Impact factor: 56.272

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.