Literature DB >> 16137096

A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

Daniel van Steenberghe1, Roland Glauser, Ulf Blombäck, Matts Andersson, Filip Schutyser, Andreas Pettersson, Inger Wendelhag.   

Abstract

BACKGROUND: Based on three-dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively.
PURPOSE: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study.
MATERIALS AND METHODS: Twenty-seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth-in-an-Hour concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan-derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure.
RESULTS: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable.
CONCLUSION: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three-dimensional oral implant planning software, of both surgical templates for flapless surgery and dental prostheses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16137096     DOI: 10.1111/j.1708-8208.2005.tb00083.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  27 in total

1.  The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT.

Authors:  B Vandenberghe; S Luchsinger; J Hostens; E Dhoore; R Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Accuracy of templates for navigated implantation made by rapid prototyping with DICOM datasets of cone beam computer tomography (CBCT).

Authors:  Jochen Weitz; Herbert Deppe; Sebastian Stopp; Tim Lueth; Steffen Mueller; Bettina Hohlweg-Majert
Journal:  Clin Oral Investig       Date:  2010-09-21       Impact factor: 3.573

Review 3.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

4.  Full rehabilitation with nobel clinician(®) and procera implant bridge(®): case report.

Authors:  D Spinelli; L Ottria; G DE Vico; R Bollero; A Barlattani; P Bollero
Journal:  Oral Implantol (Rome)       Date:  2013-10-15

5.  Calibrated segmentation of CBCT and CT images for digitization of dental prostheses.

Authors:  Veerle Wouters; Wouter Mollemans; Filip Schutyser
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-05-03       Impact factor: 2.924

6.  Immediate loading of four implants (BTLock(®)) in the maxilla and provisional restoration with guide-surgery (SimPlant, Materialise(®)): case report.

Authors:  D Spinelli; G DE Vico; R Schiavetti; M Bonino; A Pozzi; P Bollero; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-11-29

Review 7.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

8.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

9.  Open flap versus flapless placement of dental implants. A randomized controlled pilot trial.

Authors:  Enric Jané-Salas; Xavier Roselló-LLabrés; Enric Jané-Pallí; Siddharth Mishra; Raúl Ayuso-Montero; José López-López
Journal:  Odontology       Date:  2018-02-20       Impact factor: 2.634

10.  Transcrestal guided sinus lift without grafting materials: a 36 months clinical prospective study.

Authors:  D Spinelli; G DE Vico; R Condò; L Ottria; C Arcuri
Journal:  Oral Implantol (Rome)       Date:  2016-07-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.