Literature DB >> 21538159

Calibrated segmentation of CBCT and CT images for digitization of dental prostheses.

Veerle Wouters1, Wouter Mollemans, Filip Schutyser.   

Abstract

PURPOSE: State of the art computer aided implant planning procedures typically use a surgical template to transfer the digital 3D planning to the operating room. This surgical template can be generated based on an acrylic copy of the patient's removable prosthesis--the so-called radiographic guide--which is digitized using a CBCT or CT scanner. Since the same accurate fit between the surgical template and the patient as with the radiographic guide and the patient should be ensured, a procedure to accurately digitize this guide is needed.
METHODS: A procedure is created to accurately digitize radiographic guides based on a calibrated segmentation. Therefore, two steps have to be executed. First, during a calibration step a calibration object is CBCT or CT scanned and a calibration algorithm which results in an optimal threshold value is executed. Next the guide is CBCT or CT scanned and a 3D model is created using the obtained optimal threshold. To validate our method, we compared a high accuracy laser scanned copy of the guide with the generated 3D model by creating a distance map between both models.
RESULTS: The procedure was performed for different CBCT and CT scanners, and the digitization error for each scanner was defined. The 90th percentile error measured on average 0.15 mm, which was always less than the applied voxel size for all CBCT and CT test scans.
CONCLUSIONS: The calibration procedure evaluated in this study solves the known problem of digitizing a radiographic guide based on non-standardized gray value CBCT images. The procedure can easily be executed by a clinician and allows an accurate digitization of a radiographic guide using a CBCT or CT scanner. Starting from this digitization, an accurate surgical template can be made which has a good fit on the patient's remaining teeth and surrounding soft tissues.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21538159     DOI: 10.1007/s11548-011-0556-6

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  16 in total

1.  Guided surgery and presurgical prosthesis: preliminary results of 33 fully edentulous maxillae treated in accordance with the NobelGuide protocol.

Authors:  Luc Gillot; Renaud Noharet; Bernard Cannas
Journal:  Clin Implant Dent Relat Res       Date:  2010-04-23       Impact factor: 3.932

2.  Accuracy of virtually planned and template guided implant surgery on edentate patients.

Authors:  Andreas Pettersson; Ai Komiyama; Margareta Hultin; Karin Näsström; Björn Klinge
Journal:  Clin Implant Dent Relat Res       Date:  2010-05-11       Impact factor: 3.932

3.  Computed tomography-guided implant surgery for dental rehabilitation in mandible reconstructed with a fibular free flap: description of the technique.

Authors:  Giacomo De Riu; Silvio Mario Meloni; Milena Pisano; Olindo Massarelli; Antonio Tullio
Journal:  Br J Oral Maxillofac Surg       Date:  2010-12-30       Impact factor: 1.651

Review 4.  Diagnostic value of NobelGuide to minimize the need for reconstructive surgery of jaws before implant placement: a review.

Authors:  Roberto Scotti; Gerardo Pellegrino; Claudio Marchetti; Guiseppe Corinaldesi; Leonardo Ciocca
Journal:  Quintessence Int       Date:  2010 Nov-Dec       Impact factor: 1.677

5.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

6.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study.

Authors:  N Van Assche; D van Steenberghe; M E Guerrero; E Hirsch; F Schutyser; M Quirynen; R Jacobs
Journal:  J Clin Periodontol       Date:  2007-09       Impact factor: 8.728

7.  A novel stereolithographic surgical guide template for planning treatment involving a mandibular dental implant.

Authors:  Sakineh Nikzad; Abbas Azari
Journal:  J Oral Maxillofac Surg       Date:  2008-07       Impact factor: 1.895

8.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

9.  A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study.

Authors:  Daniel van Steenberghe; Roland Glauser; Ulf Blombäck; Matts Andersson; Filip Schutyser; Andreas Pettersson; Inger Wendelhag
Journal:  Clin Implant Dent Relat Res       Date:  2005       Impact factor: 3.932

10.  Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: a prospective radiological study.

Authors:  Christoph Vasak; Georg Watzak; André Gahleitner; Georg Strbac; Michael Schemper; Werner Zechner
Journal:  Clin Oral Implants Res       Date:  2011-01-18       Impact factor: 5.977

View more
  2 in total

1.  Automated implant segmentation in cone-beam CT using edge detection and particle counting.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Hilde Bosmans; Pisha Pittayapat; Pasupen Kosalagood; Onanong Silkosessak; Soontra Panmekiate
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

2.  Reconstruction of difference in sequential CT studies using penalized likelihood estimation.

Authors:  A Pourmorteza; H Dang; J H Siewerdsen; J W Stayman
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609