[Fluoroscopy-based 3D navigation of complex correction osteotomies at the proximal femur].

R Burgkart1, H Gottschling, M Roth, R Gradinger, A Schweikard.   

Abstract

BACKGROUND: Despite great advances in hip alloarthroplasty there are still numerous indications for joint-saving procedures such as correction osteotomies. Often these procedures include complex 3D rearrangements of the proximal femur, which are for the surgeon technically very demanding. The project aim was to develop a precise intraoperative virtual 3D planning tool including a detailed biomechanical analysis and enable the surgeon to realize exactly this plan by using computer-assisted techniques.
METHODS: Using only two different angled fluoro frames a simplified femoral model was inversely constructed. For navigation a passive optical system was used with a C-arm calibration kit and PC-based software. For in vitro evaluation complex osteotomies were performed on ten femora under simulated OR conditions.
RESULTS: The mean difference between the planning and real surgical outcome for the wedge size was less then 2 degrees and for the femur head center position less then 4 mm. No implant penetrated the femur neck isthmus.
CONCLUSION: Without changing the standard operative procedure the method can be of high clinical importance to improve planning accuracy and consecutive operative realization for precise fragment positioning and plate location without penetrating the isthmus of the femoral neck. And -- besides precision -- it can potentially help to reduce intraoperative complications such as implant penetration and minimize X-ray use.

Entities:  

Mesh:

Year:  2005        PMID: 16136338     DOI: 10.1007/s00132-005-0859-9

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  14 in total

1.  Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails.

Authors:  M A Slomczykowski; R Hofstetter; M Sati; C Krettek; L P Nolte
Journal:  J Orthop Trauma       Date:  2001-02       Impact factor: 2.512

2.  Virtual fluoroscopy: computer-assisted fluoroscopic navigation.

Authors:  K T Foley; D A Simon; Y R Rampersaud
Journal:  Spine (Phila Pa 1976)       Date:  2001-02-15       Impact factor: 3.468

3.  [Computer-assisted periacetabular triple osteotomy for treatment of dysplasia of the hip].

Authors:  M Jäger; B Westhoff; A Wild; R Krauspe
Journal:  Z Orthop Ihre Grenzgeb       Date:  2004 Jan-Feb

4.  Osteotomies of the hip in the prevention and treatment of osteoarthritis.

Authors:  M B Millis; R Poss; S B Murphy
Journal:  Instr Course Lect       Date:  1992

5.  Use of computed tomographic reconstruction in planning osteotomies of the hip.

Authors:  M B Millis; S B Murphy
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

6.  The hip joint as a conchoid shape.

Authors:  F Menschik
Journal:  J Biomech       Date:  1997-09       Impact factor: 2.712

7.  Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction.

Authors:  R Hofstetter; M Slomczykowski; C Krettek; G Köppen; M Sati; L P Nolte
Journal:  Comput Aided Surg       Date:  2000

8.  Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants.

Authors:  N Suhm; A L Jacob; L P Nolte; P Regazzoni; P Messmer
Journal:  Comput Aided Surg       Date:  2000

9.  Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database.

Authors:  P Messmer; G Long; N Suhm; P Regazzoni; A L Jacob
Journal:  Comput Aided Surg       Date:  2001

10.  Computer aided high tibial open wedge osteotomy.

Authors:  Peter Keppler; Florian Gebhard; Paul A Grützner; Gongli Wang; Guoyan Zheng; Tobias Hüfner; Stefan Hankemeier; Lutz-Peter Nolte
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.