Literature DB >> 11232651

Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails.

M A Slomczykowski1, R Hofstetter, M Sati, C Krettek, L P Nolte.   

Abstract

OBJECTIVES: Orthopaedic procedures that use fluoroscopy require intraoperative mental navigation of the surgical tools in a three-dimensional space. Moreover, because of their reliance on real-time monitoring, such procedures are frequently associated with increased x-ray exposure. The goal of this study was to develop a computer-guided surgical navigation system based on fluoroscopic images that not only facilitates direction of surgical tools within anatomy, but also provides constant feedback without the need for radiologic updates. To evaluate the feasibility of the new technology, the authors used it on cases requiring distal locking of femoral nails.
METHODS: The hardware components of the system include an instrumented C-arm, optoelectronic position sensor, stereotactic tools, and custom-made software. Computer integration of these devices permitted C-arm alignment assistance and real-time navigation control without constant x-ray exposure. The nails were locked in a variety of media, including plastic femurs, dry human femoral specimens, human cadavers, and one clinical case. Unreamed femoral nail sizes ranged from 9/340 to 12/400. Radiographs were taken to confirm that screws were positioned correctly, and fluoroscopic time associated with the locking procedure was recorded.
RESULTS: All distal holes were locked successfully. In eight (11 percent) of seventy-six holes, the drill bit touched the canal of the locking hole, albeit with no damage to the nail and no clinical consequences. The fluoroscopy time per pair of screws was 1.67 seconds.
CONCLUSIONS: The developed system enables the physician to precisely navigate surgical instruments throughout the anatomy using just a few computer-calibrated radiographic images. The total radiation time per procedure can be significantly reduced because additional x-ray exposure is not required for tool navigation.

Entities:  

Mesh:

Year:  2001        PMID: 11232651     DOI: 10.1097/00005131-200102000-00009

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  10 in total

1.  [Fluoroscopy-based 3D navigation of complex correction osteotomies at the proximal femur].

Authors:  R Burgkart; H Gottschling; M Roth; R Gradinger; A Schweikard
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

Review 2.  [Precision in orthopaedic computer navigation].

Authors:  T Hüfner; D Kendoff; M Citak; J Geerling; C Krettek
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

3.  Distal locking of tibial nails : a new device to reduce radiation exposure.

Authors:  George Anastopoulos; Panagiotis G Ntagiopoulos; Dionisios Chissas; Athanasios Papaeliou; Antonios Asimakopoulos
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

4.  Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation.

Authors:  Erin J Smith; Hisham A Al-Sanawi; Braden Gammon; Paul J St John; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-25       Impact factor: 2.924

5.  Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

Authors:  Ilker Hacihaliloglu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-11       Impact factor: 2.924

6.  Ultrasound imaging and segmentation of bone surfaces: A review.

Authors:  Ilker Hacihaliloglu
Journal:  Technology (Singap World Sci)       Date:  2017-03-31

7.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

8.  [Fluoroscopy based surgical navitation vs. mechanical guidance system for percutaneous interventions. A controlled prospective study exemplified by distal locking of intramedullary nails].

Authors:  N Suhm; L A Jacob; I Zuna; P Regazzoni; P Messmer
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

9.  Validity of a Novel Digitally Enhanced Skills Training Station for Freehand Distal Interlocking.

Authors:  Torsten Pastor; Tatjana Pastor; Philipp Kastner; Firas Souleiman; Matthias Knobe; Boyko Gueorguiev; Markus Windolf; Jan Buschbaum
Journal:  Medicina (Kaunas)       Date:  2022-06-07       Impact factor: 2.948

Review 10.  Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.

Authors:  Jan Kubicek; Filip Tomanec; Martin Cerny; Dominik Vilimek; Martina Kalova; David Oczka
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.