Literature DB >> 11295852

Surgical navigation based on fluoroscopy--clinical application for computer-assisted distal locking of intramedullary implants.

N Suhm1, A L Jacob, L P Nolte, P Regazzoni, P Messmer.   

Abstract

OBJECTIVE: Fluoroscopy is used to guide surgical instruments during orthopedic procedures. Radiation exposure and lack of spatial information are drawbacks of this method. Improvements are expected when fluoroscopy-based surgical navigation is used for intraoperative guidance, e.g., in computer-assisted distal locking of intramedullary implants. PATIENTS AND METHODS: The method was applied to 42 interlocking procedures during implantation of the short proximal femoral nail in 27 patients with pertrochanteric femoral fractures. Precision of interlocking, exposure time, operating time, and number of personnel required for computer-assisted distal locking were recorded.
RESULTS: One misplaced interlocking screw was observed (2.3%), and contact between the drill bit and the nail during drilling was noticed in 8 cases (19%). The average exposure time was 16 seconds (range 4-42 seconds), and the procedure took an average of 43 min (range 20-70 min). The number of persons required for computer-assisted distal locking was reduced from three to one within the course of the study.
CONCLUSIONS: Fluoroscopy-based surgical navigation provided precise intraoperative guidance for computer-assisted distal locking with minimal use of fluoroscopy. The complex system and related procedure times may be drawbacks in this application. Clinical studies are underway to define implants and surgical procedures where intraoperative guidance by fluoroscopy-based surgical navigation is beneficial for the patient and/or surgeon. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 11295852     DOI: 10.1002/igs.1001

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  15 in total

1.  [CT and fluoroscopy based navigation in pelvic surgery].

Authors:  U Stöckle; B König; K Schaser; I Melcher; N P Haas
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

Authors:  K Wendl; J von Recum; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm.

Authors:  H Esfandiari; S Amiri; D D Lichti; C Anglin
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

4.  [Fluoroscopy-based 3D navigation of complex correction osteotomies at the proximal femur].

Authors:  R Burgkart; H Gottschling; M Roth; R Gradinger; A Schweikard
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

5.  Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation.

Authors:  Erin J Smith; Hisham A Al-Sanawi; Braden Gammon; Paul J St John; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-25       Impact factor: 2.924

6.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

7.  Model-based registration of preprocedure MR and intraprocedure US of the lumbar spine.

Authors:  Delaram Behnami; Alireza Sedghi; Emran Mohammad Abu Anas; Abtin Rasoulian; Alexander Seitel; Victoria Lessoway; Tamas Ungi; David Yen; Jill Osborn; Parvin Mousavi; Robert Rohling; Purang Abolmaesumi
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-18       Impact factor: 2.924

Review 8.  Meta-analysis suggests that the electromagnetic technique is better than the free-hand method for the distal locking during intramedullary nailing procedures.

Authors:  Yanbin Zhu; Hengrui Chang; Yiyang Yu; Wei Chen; Song Liu; Yingze Zhang
Journal:  Int Orthop       Date:  2016-06-02       Impact factor: 3.075

9.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

10.  Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system.

Authors:  Xiangqian Chen; Yu Wang; Gang Zhu; Weijun Zhang; Gang Zhou; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2020-01-09       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.