Literature DB >> 11835613

Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database.

P Messmer1, G Long, N Suhm, P Regazzoni, A L Jacob.   

Abstract

We present a new concept with mathematical background for the construction of a three-dimensional (3D) volumetric model of the human tibia based on two conventional orthogonal two-dimensional (2D) radiographic images. This approach is supported by a computer database containing a collection of 80 2D/3D image data sets of individual cadaveric tibiae. For each of these tibiae, the database contains digitized 2D orthogonal radiographic images in both anterior and lateral views, and the corresponding 3D CT data obtained by computerized tomography. To obtain a 3D model of a tibia for a given patient, shape matching is performed. The computer finds the most similar tibia to the patient's tibia among the 2D radiographic images in the database by applying a matching process. To improve accuracy, a 2D image warping procedure can be applied on the slices of the selected bone prior to 3D reconstruction. The warping process is controlled by the contour data of the two orthogonal views. We found that the 3D model thus achieved was useful for virtual preoperative planning and for simulation of the internal fixation of long bones. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11835613     DOI: 10.1002/igs.10009

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  8 in total

1.  Mechanical behavior of screws in normal and osteoporotic bone.

Authors:  J Seebeck; J Goldhahn; M M Morlock; E Schneider
Journal:  Osteoporos Int       Date:  2004-10-27       Impact factor: 4.507

2.  [Fluoroscopy-based 3D navigation of complex correction osteotomies at the proximal femur].

Authors:  R Burgkart; H Gottschling; M Roth; R Gradinger; A Schweikard
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

3.  3D patient-specific model of the tibia from CT for orthopedic use.

Authors:  Raide A González-Carbonell; Armando Ortiz-Prado; Victor H Jacobo-Armendáriz; Yosbel A Cisneros-Hidalgo; Armando Alpízar-Aguirre
Journal:  J Orthop       Date:  2015-01-31

4.  A CT database for research, development and education: concept and potential.

Authors:  Peter Messmer; Felix Matthews; Augustinus Ludwig Jacob; Ron Kikinis; Pietro Regazzoni; Hansruedi Noser
Journal:  J Digit Imaging       Date:  2007-03       Impact factor: 4.056

5.  Radiographic reconstruction of lower-extremity bone fragments: a first trial.

Authors:  Steffen Schumann; Richard Bieck; Rainer Bader; Johannes Heverhagen; Lutz-P Nolte; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-16       Impact factor: 2.924

6.  Calcaneal osteotomy preoperative planning system with 3D full-sized computer-assisted technology.

Authors:  Yi-Jiun Chou; Shuh-Ping Sun; Hsin-Hua Liu
Journal:  J Med Syst       Date:  2010-03-30       Impact factor: 4.460

7.  Reliability and concurrent validity of angle measurements in lower limb: EOS 3D goniometer versus 2D manual goniometer.

Authors:  Jun Huang; Fanli Tian; Zhigang Zhang; Weidong Shi; Jun Lin; Liang Chen; Huilin Yang
Journal:  J Orthop Translat       Date:  2020-05-20       Impact factor: 5.191

8.  Metal artifacts from titanium and steel screws in CT, 1.5T and 3T MR images of the tibial Pilon: a quantitative assessment in 3D.

Authors:  Shairah Radzi; Gary Cowin; Mark Robinson; Jit Pratap; Andrew Volp; Michael A Schuetz; Beat Schmutz
Journal:  Quant Imaging Med Surg       Date:  2014-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.