Literature DB >> 10611878

Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty.

W G Paprosky1, N V Greidanus, J Antoniou.   

Abstract

Obtaining predictable, stable fixation of revision femoral implants is important for the long-term success of revision hip arthroplasty. The authors report on minimum 10 years clinical and radiographic followup of 170 patients with extensively coated cementless revision femoral components. With a range of followup of 10 to 16 years and a mean of 13.2 years, a survivorship of greater than 95% was reported. Clinically, the average Postel-D'Aubigne pain and walking score improved from a preoperative score of 5.4 points to 10.8 points postoperatively. Eighty-two percent of the hips had radiographic evidence of a bone-ingrown prosthesis and 13.9% had evidence of stable fibrous fixation. Four percent of stems were unstable as seen on radiographs. Six stems were revised to larger extensively coated stems and one stem is causing pain and is unstable but has yet to be revised. The overall mechanical failure rate was 4.1%. Stress shielding was greatest in patients with stems larger than 16.5 mm and in osteoporotic bone (Dorr Type C). Nine percent of patients had significant thigh pain including all of the patients with unstable stems. In the presence of bone loss in the proximal metaphyseal region of the femur, fixation of the femoral component is predictable when optimizing prosthetic-bone fit in the diaphyseal region of the femur using an extensively coated femoral component.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10611878     DOI: 10.1097/00003086-199912000-00024

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  63 in total

1.  Hip painful prosthesis: surgical view.

Authors:  Antonio Spinarelli; Vittorio Patella; Vito Conserva; Giovanni Vicenti; Vito Pesce; Silvio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2011-05

Review 2.  Assessment of fixation in cementless femoral revision of total hip arthroplasty: comparison of the Engh score versus radiolucent line measurement.

Authors:  Olivier Roche; Julien Girard; François Canovas; Henri Migaud; François Bonnomet; Mathias Goldschild; Pierre Le Béguec
Journal:  Int Orthop       Date:  2015-11-17       Impact factor: 3.075

3.  Distal locking stem for revision femoral loosening and peri-prosthetic fractures.

Authors:  Patrice Mertl; Remy Philippot; Philippe Rosset; Henri Migaud; Jacques Tabutin; Denis Van de Velde
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

4.  [Cementless stems of the hip. Current status].

Authors:  H Effenberger; M Imhof; U Witzel; S Rehart
Journal:  Orthopade       Date:  2005-05       Impact factor: 1.087

5.  [Principles of fixation of the cementless modular revision stem Revitan].

Authors:  B Fink; M Fuerst; M Hahn; L Thybaud; H-P Sieber; G Delling
Journal:  Unfallchirurg       Date:  2005-12       Impact factor: 1.000

6.  Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty.

Authors:  T Gosens; E J van Langelaan
Journal:  Int Orthop       Date:  2005-05-18       Impact factor: 3.075

7.  Why revision total hip arthroplasty fails.

Authors:  Bryan D Springer; Thomas K Fehring; William L Griffin; Susan M Odum; John L Masonis
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

8.  Revision of the deficient proximal femur with a proximal femoral allograft.

Authors:  Oleg Safir; Catherine F Kellett; Michael Flint; David Backstein; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2008-10-30       Impact factor: 4.176

9.  Are short fully coated stems adequate for "simple" femoral revisions?

Authors:  Matthew W Tetreault; Sanjai K Shukla; Paul H Yi; Scott M Sporer; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Midterm to long-term followup of staged reimplantation for infected hip arthroplasty.

Authors:  Joaquin Sanchez-Sotelo; Daniel J Berry; Arlen D Hanssen; Miguel E Cabanela
Journal:  Clin Orthop Relat Res       Date:  2008-09-24       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.