Literature DB >> 16132934

The reproducibility of left ventricular volume and mass measurements: a comparison between dual-inversion-recovery black-blood sequence and SSFP.

Sarah Clay1, Khaled Alfakih, Daniel R Messroghli, Timothy Jones, John P Ridgway, Mohan U Sivananthan.   

Abstract

The aim of this study was to compare a dual-inversion-recovery black-blood (BB) magnetic resonance imaging (MRI) sequence with steady-state free precession (SSFP) for the assessment of left ventricular parameters. The improved endocardial border definition seen with SSFP was not observed at the epicardial border. Improvements in segmentation at the left ventricular epicardial border have been observed with this black-blood sequence. Left ventricular (LV) mass and LV end-diastolic volume (EDV) measurements as well as inter-observer and intra-observer variability were compared between images acquired with a dual inversion BB and SSFP sequence. The mean+/-1 standard deviation (SD) for LV EDV was 178.3+/-52.7 ml measured with SSFP and 158.8+/-62.2 ml with BB. This difference was not statistically significant (p=0.22). For SSFP, the mean value of LV mass was 124.0+/-27.0 g and 147.5+/-37.4 g for BB, a statistically significant difference (p<0.0001). The dual-inversion-recovery BB imaging showed improved reproducibility for LV mass measurements compared with SSFP and improved spatial resolution. For studies requiring LV mass measurements, the dual-inversion-recovery BB sequence offers improved spatial resolution and improved reproducibility to SSFP.

Entities:  

Mesh:

Year:  2005        PMID: 16132934     DOI: 10.1007/s00330-005-2853-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

1.  Free-breathing black-blood coronary MR angiography: initial results.

Authors:  M Stuber; R M Botnar; K V Kissinger; W J Manning
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility.

Authors:  James C C Moon; Christine H Lorenz; Jane M Francis; Gillian C Smith; Dudley J Pennell
Journal:  Radiology       Date:  2002-06       Impact factor: 11.105

3.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

Review 4.  Implications of SENSE MR in routine clinical practice.

Authors:  Johan S van den Brink; Yuji Watanabe; Christiane K Kuhl; Taylor Chung; Raja Muthupillai; Marc Van Cauteren; Kei Yamada; Steven Dymarkowski; Jan Bogaert; Jeff H Maki; Celso Matos; Jan W Casselman; Romhild M Hoogeveen
Journal:  Eur J Radiol       Date:  2003-04       Impact factor: 3.528

Review 5.  MRI in coronary artery disease.

Authors:  Jörg Barkhausen; Peter Hunold; Kai-Uwe Waltering
Journal:  Eur Radiol       Date:  2004-09-04       Impact factor: 5.315

6.  Black blood dual phase turbo FLASH MR imaging of the heart.

Authors:  S Sinha; U Sinha
Journal:  J Magn Reson Imaging       Date:  1996 May-Jun       Impact factor: 4.813

7.  Estimation of the left ventricular ejection fraction using a novel multiphase, dark-blood, breath-hold MR imaging technique.

Authors:  S Sinha; R Mather; U Sinha; J Goldin; G Fonarow; H C Yoon
Journal:  AJR Am J Roentgenol       Date:  1997-07       Impact factor: 3.959

8.  Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging.

Authors:  C H Lorenz; E S Walker; V L Morgan; S S Klein; T P Graham
Journal:  J Cardiovasc Magn Reson       Date:  1999       Impact factor: 5.364

9.  Technical note: rapid measurement of left ventricular mass by spin echo magnetic resonance imaging.

Authors:  S M Forbat; S P Karwatowski; P D Gatehouse; D N Firmin; D B Longmore; S R Underwood
Journal:  Br J Radiol       Date:  1994-01       Impact factor: 3.039

10.  Dimensional accuracy of magnetic resonance in studies of the heart.

Authors:  D B Longmore; R H Klipstein; S R Underwood; D N Firmin; G N Hounsfield; M Watanabe; C Bland; K Fox; P A Poole-Wilson; R S Rees
Journal:  Lancet       Date:  1985-06-15       Impact factor: 79.321

View more
  8 in total

1.  Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function.

Authors:  Torleif A Sandner; Philip Houck; Val M Runge; Spencer Sincleair; Armin M Huber; Daniel Theisen; Maximilian F Reiser; Bernd J Wintersperger
Journal:  Eur Radiol       Date:  2008-05-08       Impact factor: 5.315

2.  Diagnostic accuracy and variability of three semi-quantitative methods for assessing right ventricular systolic function from cardiac MRI in patients with acquired heart disease.

Authors:  Jérôme Caudron; Jeannette Fares; Pierre-Hugues Vivier; Valentin Lefebvre; Caroline Petitjean; Jean-Nicolas Dacher
Journal:  Eur Radiol       Date:  2011-05-26       Impact factor: 5.315

3.  Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study.

Authors:  Jean-Christophe Lasalarie; Jean-Michel Serfaty; Christophe Carre; David Messika-Zeitoun; Christophe Jeannot; Elisabeth Schouman-Claeys; Jean-Pierre Laissy
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

4.  The cardiac MRI substudy to ongoing telmisartan alone and in combination with ramipril global endpoint trial/telmisartan randomized assessment study in ACE-intolerant subjects with cardiovascular disease: analysis protocol and baseline characteristics.

Authors:  Brett R Cowan; Alistair A Young; Craig Anderson; Robert N Doughty; Rungroj Krittayaphong; Eva Lonn; Thomas H Marwick; Chris M Reid; John E Sanderson; Roland E Schmieder; Koon Teo; Angela K Wadham; Stephen G Worthley; Cheuk-Man Yu; Salim Yusuf; Garry L Jennings
Journal:  Clin Res Cardiol       Date:  2009-04-04       Impact factor: 5.460

5.  Four-dimensional flow assessment of pulmonary artery flow and wall shear stress in adult pulmonary arterial hypertension: results from two institutions.

Authors:  Alex J Barker; Alejandro Roldán-Alzate; Pegah Entezari; Sanjiv J Shah; Naomi C Chesler; Oliver Wieben; Michael Markl; Christopher J François
Journal:  Magn Reson Med       Date:  2014-06-27       Impact factor: 4.668

6.  Intra-observer and interobserver variability of biventricular function, volumes and mass in patients with congenital heart disease measured by CMR imaging.

Authors:  Saskia E Luijnenburg; Daniëlle Robbers-Visser; Adriaan Moelker; Hubert W Vliegen; Barbara J M Mulder; Willem A Helbing
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-16       Impact factor: 2.357

7.  Non-invasive assessment of cardiac function and pulmonary vascular resistance in an canine model of acute thromboembolic pulmonary hypertension using 4D flow cardiovascular magnetic resonance.

Authors:  Alejandro Roldán-Alzate; Alex Frydrychowicz; Kevin M Johnson; Heidi Kellihan; Naomi C Chesler; Oliver Wieben; Christopher J François
Journal:  J Cardiovasc Magn Reson       Date:  2014-03-13       Impact factor: 5.364

8.  Impact of a training program incorporating cardiac magnetic resonance imaging on the accuracy and reproducibility of two-dimensional echocardiographic measurements of left ventricular volumes and ejection fraction.

Authors:  Yosuke Nabeshima; Hidehiro Namisaki; Toshihiro Teshima; Yasuhiko Kurashige; Akiko Kakio; Azusa Fukumitsu; Yutaka Otsuji; Masaaki Takeuchi
Journal:  Cardiovasc Ultrasound       Date:  2019-10-31       Impact factor: 2.062

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.