Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility.

James C C Moon1, Christine H Lorenz, Jane M Francis, Gillian C Smith, Dudley J Pennell.   

Abstract

PURPOSE: To compare fast imaging with steady-state precession (FISP) and fast low-angle shot (FLASH) magnetic resonance acquisitions to quantify left ventricular volumes, mass, and function and to determine if the two techniques are comparable.
MATERIALS AND METHODS: Left ventricular volume studies were performed in 10 patients with heart failure and in 10 healthy subjects by using FISP and FLASH imaging. Identical section positions were used for section-by-section contour comparisons. Manual analysis was performed by two experienced observers. The study was repeated on a different day and interobserver and interstudy reproducibility assessed.
RESULTS: With FISP, end-diastolic volume was larger (healthy subjects: +18 mL [13%], P <.001; patients: +6 mL [3%], not significant), end-systolic volume larger (healthy subjects: +9 mL [17%], P =.001; patients: +8 mL [6%], P =.001) and left ventricular mass smaller (healthy subjects: -25 g (19%), P <.001; patients: -21 g (11%), P <.001). There were no significant differences in ejection fraction. Both sequences had excellent interstudy and interobserver reproducibility, with statistically better reproducibility for interstudy healthy-subject ejection fraction on FISP images (P =.05). Section-by-section analysis determined that at FISP, endocardial contours were drawn larger and the epicardial contours smaller than on FLASH images. FISP enabled better delineation of epicardial fat from myocardium, of blood-myocardium interface in areas of trabeculation or papillary muscles, and of the atrioventricular ring.
CONCLUSION: FISP produces small but significantly higher left ventricular volume measurements, as compared with FLASH imaging. FLASH imaging and FISP have similar reproducibility.

Entities:  

Mesh:

Year:  2002        PMID: 12034951     DOI: 10.1148/radiol.2233011181

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  88 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

3.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

4.  [Determining global heart function with real time TrueFISP in one respiratory cycle].

Authors:  B J Wintersperger; K Nikolaou; O Mühling; A Huber; O Dietrich; M Nittka; B Kiefer; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2004-02       Impact factor: 0.635

5.  Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla--a pilot study.

Authors:  Florian von Knobelsdorff-Brenkenhoff; Tobias Frauenrath; Marcel Prothmann; Matthias A Dieringer; Fabian Hezel; Wolfgang Renz; Kerstin Kretschel; Thoralf Niendorf; Jeanette Schulz-Menger
Journal:  Eur Radiol       Date:  2010-07-17       Impact factor: 5.315

6.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  Circulation       Date:  2010-05-17       Impact factor: 29.690

7.  Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.

Authors:  Kai Nassenstein; Holger Eberle; Stefan Maderwald; Christoph J Jensen; Christina Heilmaier; Thomas Schlosser; Oliver Bruder
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

Review 8.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  J Am Coll Cardiol       Date:  2010-06-08       Impact factor: 24.094

Review 9.  Cardiovascular magnetic resonance and the evaluation of heart failure.

Authors:  James C C Moon; Sanjay K Prasad
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

10.  Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes.

Authors:  M G Danilouchkine; J J M Westenberg; B P F Lelieveldt; J H C Reiber
Journal:  MAGMA       Date:  2005-01-28       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.