Literature DB >> 16124960

Revision hip arthroplasty using strut allografts and fully porous-coated stems.

Young-Hoo Kim1, Jun-Shik Kim.   

Abstract

At a minimum of 10 years after surgery, we prospectively evaluated the clinical and radiographic outcomes of revision total hip arthroplasties using cortical strut allografts and fully porous-coated cementless revision femoral components in patients with massive femoral bone deficiency. There were 21 men and 33 women (54 hips) in the series, with patients' mean age at the time of index revision being 54.6 years (range, 36 to 65 years). All femurs had 2 or 3 fresh-frozen femoral strut allografts. The Harris hip score improved from a mean of 21 points before revision surgery to a mean of 83 points at the latest case review. Two femoral stems (4%) had aseptic loosening and were revised. All allografts were predictably united to the host femur. On the basis of favorable results at a mean follow-up of 10.5 years, we recommend, as a salvage procedure, the use of fully porous-coated cementless femoral stems and strut allografts in revision surgery of the hip for massive femoral bone loss.

Entities:  

Mesh:

Year:  2005        PMID: 16124960     DOI: 10.1016/j.arth.2004.09.054

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  What is the survivorship of fully coated femoral components in revision hip arthroplasty?

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

2.  Increase of cortical bone after a cementless long stem in periprosthetic fractures.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos; Rosário Madero
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

3.  Strut grafts in revision hip arthroplasty faced with femoral bone defects: an experimental analysis.

Authors:  Stefan Kinkel; Marc N Thomsen; Jan Nadorf; Christian Heisel; Michael C Tanner; Eike Jakubowitz
Journal:  Int Orthop       Date:  2014-01-03       Impact factor: 3.075

4.  High Survivorship With Cementless Stems and Cortical Strut Allografts for Large Femoral Bone Defects in Revision THA.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim; Devarshi Rastogi
Journal:  Clin Orthop Relat Res       Date:  2015-05-27       Impact factor: 4.176

5.  Strut Onlay Allograft in Revision Arthroplasty: Osseous Union and Clinical Outcome.

Authors:  Dietmar Dammerer; Alexander Wurm; Clemens Frischhut; Johannes Petersen; Miar Ouaret; Michael Liebensteiner
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

6.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

7.  Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty.

Authors:  Raju Vaishya; Mrinal Sharma; Rajeev Raj Chaudhary
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.