Literature DB >> 20050736

Root and bone response to the proximity of a mini-implant under orthodontic loading.

Yang-Ku Lee1, Jong-Wan Kim, Seung-Hak Baek, Tae-Woo Kim, Young-Il Chang.   

Abstract

OBJECTIVE: To determine the histological reaction of the root and bone as a mini-implant approaches the root.
MATERIALS AND METHODS: Two kinds of mini-implants were inserted into the buccal alveolar bone of 4 beagles (2 males and 2 females). The specimens were classified as the near-root group, the PDL contact group, the root contact group, and the root perforation group. Cementum resorption, dentin resorption, cementum repair, cementum growth, ankylosis, root cracking, and root fracture were assessed as the implant neared the root.
RESULTS: The incidence of root resorption increased when the mini-implant was less than 0.6 mm from the root in the near-root group and PDL contact group. Root cracking and root fracture occurred in the root contact group and root perforation group. Bone resorption and ankylosis were observed in some specimens. However, some specimens of the PDL contact group and root contact group had cementum growth or little root resorption despite proximity to the root. In the root perforation group, root resorption and ankylosis occurred on the side opposite the insertion.
CONCLUSIONS: There is a risk of root contact and severe tissue damage from a thick mini-implant and the drilling procedure, either of which can induce root resorption or ankylosis. Use of smaller mini-implants may reduce root contact and tissue damage. However, the small mini-implant may need enhancement of its stability.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20050736      PMCID: PMC8985715          DOI: 10.2319/070209-369.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  26 in total

1.  Method for the placement of palatal implants.

Authors:  Tosun Tosun; Ahmet Keles; Nejat Erverdi
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Jan-Feb       Impact factor: 2.804

2.  Template fabrication for a midpalatal orthodontic implant: technical note.

Authors:  William Martin; Michael Heffernan; James Ruskin
Journal:  Int J Oral Maxillofac Implants       Date:  2002 Sep-Oct       Impact factor: 2.804

3.  Intrusion of posterior teeth using mini-screw implants.

Authors:  Young-Chel Park; Seung-Yeon Lee; Doo-Hyung Kim; Sung-Hoon Jee
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-06       Impact factor: 2.650

4.  Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study.

Authors:  Yuan-Hou Chen; Hao-Hueng Chang; Yi-Jane Chen; David Lee; Hsien-Hsiung Chiang; Chung-Chen Jane Yao
Journal:  Clin Oral Implants Res       Date:  2007-10-23       Impact factor: 5.977

5.  Rotational resistance of surface-treated mini-implants.

Authors:  Seong-Hun Kim; Shin-Jae Lee; Il-Sik Cho; Seong-Kyun Kim; Tae-Woo Kim
Journal:  Angle Orthod       Date:  2009-09       Impact factor: 2.079

6.  Skeletal anchorage system for open-bite correction.

Authors:  M Umemori; J Sugawara; H Mitani; H Nagasaka; H Kawamura
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-02       Impact factor: 2.650

7.  Mini-implant for orthodontic anchorage.

Authors:  R Kanomi
Journal:  J Clin Orthod       Date:  1997-11

8.  Root repair after injury from mini-screw.

Authors:  Karlien Asscherickx; Bart Vande Vannet; Heiner Wehrbein; Mehran Moradi Sabzevar
Journal:  Clin Oral Implants Res       Date:  2005-10       Impact factor: 5.977

9.  Stability of mini-screws invading the dental roots and their impact on the paradental tissues in beagles.

Authors:  Yoon-Goo Kang; Ji-Young Kim; Young-Jun Lee; Kyu-Rhim Chung; Young-Guk Park
Journal:  Angle Orthod       Date:  2009-03       Impact factor: 2.079

10.  Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment.

Authors:  Onur Kadioglu; Tamer Büyükyilmaz; Björn U Zachrisson; B Giuliano Maino
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-09       Impact factor: 2.650

View more
  14 in total

1.  Effect of loaded orthodontic miniscrew implant on compressive stresses in adjacent periodontal ligament.

Authors:  Mhd Hassan Albogha; Ichiro Takahashi
Journal:  Angle Orthod       Date:  2018-09-19       Impact factor: 2.079

2.  Stability comparison between commercially available mini-implants and a novel design: part 1.

Authors:  Christine Hong; Haofu Lee; Richard Webster; Jinny Kwak; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

3.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

4.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

5.  Comparison of short-term effects between face mask and skeletal anchorage therapy with intermaxillary elastics in patients with maxillary retrognathia.

Authors:  Cahide Ağlarcı; Elçin Esenlik; Yavuz Fındık
Journal:  Eur J Orthod       Date:  2015-07-27       Impact factor: 3.075

Review 6.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

7.  Assessing the amount of interdental bone in posterior areas of the mandible for placing orthodontic mini-implants.

Authors:  Nasrin Esfahanizadeh; Damoun Shahraki; Hamidreza Daneshparvar; Ahmad Reza Talaei Pour; Mohammad Ali Saghiri; Ahmad Sheibaninia; Shadab Rashtak
Journal:  J Dent (Tehran)       Date:  2013-05

8.  Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants.

Authors:  Ho-Young Kim; Sang-Cheol Kim
Journal:  Korean J Orthod       Date:  2016-11-14       Impact factor: 1.372

9.  Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion.

Authors:  Il-Sik Cho; Tae-Woo Kim; Sug-Joon Ahn; Il-Hyung Yang; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

10.  Narrow- versus mini-implants at crestal and subcrestal bone levels. Experimental study in beagle dogs at three months.

Authors:  José Luis Calvo-Guirado; Carlos Pérez-Albacete; Antonio Aguilar-Salvatierra; José E de Val Maté-Sánchez; Rafael A Delgado-Ruiz; Marcus Abboud; Eugenio Velasco; Gerardo Gómez-Moreno; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-12-11       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.