Literature DB >> 16088885

Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil.

Scott B Reeder1, Bernd J Wintersperger, Olaf Dietrich, Titus Lanz, Andreas Greiser, Maximilian F Reiser, Gary M Glazer, Stefan O Schoenberg.   

Abstract

In this work, two practical methods for the measurement of signal-to-noise-ratio (SNR) performance in parallel imaging are described. Phantoms and human studies were performed with a 32-channel cardiac coil in the context of ultrafast cardiac CINE imaging at 1.5 T using steady-state free precession (SSFP) and TSENSE. SNR and g-factor phantom measurements using a "multiple acquisition" method were compared to measurements from a "difference method". Excellent agreement was seen between the two methods, and the g-factor shows qualitative agreement with theoretical predictions from the literature. Examples of high temporal (42.6 ms) and spatial (2.1x2.1x8 mm3) resolution cardiac CINE SSFP images acquired from human volunteers using TSENSE are shown for acceleration factors up to 7. Image quality agrees qualitatively with phantom SNR measurements, suggesting an optimum acceleration of 4. With this acceleration, a cardiac function study consisting of 6 image planes (3 short-axis views, 3 long-axis views) was obtained in an 18-heartbeat breath-hold. Copyright (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16088885     DOI: 10.1002/mrm.20636

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  90 in total

1.  Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

Authors:  Bernd J Wintersperger; Spencer Sincleair; Val M Runge; Olaf Dietrich; Armin Huber; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

2.  Measuring signal-to-noise ratio in partially parallel imaging MRI.

Authors:  Frank L Goerner; Geoffrey D Clarke
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

3.  High resolution navigated three-dimensional T₁-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 Tesla.

Authors:  Scott K Nagle; Reed F Busse; Anja C Brau; Jean H Brittain; Alex Frydrychowicz; Yuji Iwadate; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2012-05-30       Impact factor: 4.813

4.  The Dixon technique and the frequency-selective fat suppression technique in three-dimensional T1 weighted MRI of the liver: a comparison of contrast-to-noise ratios of hepatocellular carcinomas-to-liver.

Authors:  Y Takatsu; T Akasaka; T Miyati
Journal:  Br J Radiol       Date:  2015-04-02       Impact factor: 3.039

5.  High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

Authors:  Winfried A Willinek; Thomas Bayer; Jürgen Gieseke; Marcus von Falkenhausen; Torsten Sommer; Romhild Hoogeveen; Kai Wilhelm; Horst Urbach; Hans H Schild
Journal:  Eur Radiol       Date:  2006-08-30       Impact factor: 5.315

6.  Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Authors:  Roland Bammer; Thomas A Hope; Murat Aksoy; Marcus T Alley
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

7.  Bayesian parallel imaging with edge-preserving priors.

Authors:  Ashish Raj; Gurmeet Singh; Ramin Zabih; Bryan Kressler; Yi Wang; Norbert Schuff; Michael Weiner
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

Review 8.  MRA of abdominal vessels: technical advances.

Authors:  Henrik J Michaely; Olaf Dietrich; Kambiz Nael; Sabine Weckbach; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2006-05-24       Impact factor: 5.315

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  3-T navigator parallel-imaging coronary MR angiography: targeted-volume versus whole-heart acquisition.

Authors:  Shixin Chang; Matthew D Cham; Shuguang Hu; Yi Wang
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.