Literature DB >> 16082572

Quantification of periprosthetic valve leakage with multiple regurgitation jets by magnetic resonance imaging.

A Pflaumer1, M Schwaiger, J Hess, R Lange, H Stern.   

Abstract

A patient with aortic prosthetic valve endocarditis required replacement of the prosthesis, After initial recovery, his left ventricular function gradually declined and echocardiography revealed minor paravalvular leakage and a cavern around the prosthesis. Magnetic resonance imaging was performed, flow-imaging and volume-based measurements showed high-grade paravalvular leakage of 45 and 58% regurgitant fraction, respectively. Intraoperatively, the dehiscence of more than half of the circumference of the aortic prosthesis was seen. This study shows that MRI can accurately assess even periprosthetic valve leakage with multiple regurgitation jets.

Entities:  

Mesh:

Year:  2005        PMID: 16082572     DOI: 10.1007/s00246-005-0821-y

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  6 in total

1.  Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

Authors:  R Botnar; E Nagel; M B Scheidegger; E M Pedersen; O Hess; P Boesiger
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

2.  Artifacts, truths, and consequences.

Authors:  L G Rudski; M H Picard
Journal:  Am J Med       Date:  2000-05       Impact factor: 4.965

3.  Heart motion adapted cine phase-contrast flow measurements through the aortic valve.

Authors:  S Kozerke; M B Scheidegger; E M Pedersen; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 T.

Authors:  M B Edwards; K M Taylor; F G Shellock
Journal:  J Magn Reson Imaging       Date:  2000-08       Impact factor: 4.813

5.  Prosthetic heart valve evaluation by magnetic resonance imaging.

Authors:  J M Hasenkam; S Ringgaard; K Houlind; R M Botnar; H Stødkilde-Jørgensen; P Boesiger; E M Pedersen
Journal:  Eur J Cardiothorac Surg       Date:  1999-09       Impact factor: 4.191

6.  Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment.

Authors:  Titus Kuehne; Maythem Saeed; Charles B Higgins; Kelly Gleason; Gabriele A Krombach; Oliver M Weber; Alastair J Martin; Daniel Turner; David Teitel; Phillip Moore
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

  6 in total
  6 in total

Review 1.  Aortic valvular imaging with cardiovascular magnetic resonance: seeking for comprehensiveness.

Authors:  Gianluca De Rubeis; Nicola Galea; Isabella Ceravolo; Gian Marco Dacquino; Iacopo Carbone; Carlo Catalano; Marco Francone
Journal:  Br J Radiol       Date:  2019-07-18       Impact factor: 3.039

Review 2.  Cardiac imaging in prosthetic paravalvular leaks.

Authors:  Carla Lázaro; Rocio Hinojar; Jose Luis Zamorano
Journal:  Cardiovasc Diagn Ther       Date:  2014-08

Review 3.  Cardiovascular magnetic resonance imaging for valvular heart disease.

Authors:  Angela Morello; Eli V Gelfand
Journal:  Curr Heart Fail Rep       Date:  2009-09

4.  Cardiovascular magnetic resonance and transesophageal echocardiography in patients with prosthetic valve paravalvular leaks: towards an accurate quantification and stratification.

Authors:  Maciej Haberka; Magdalena Malczewska; Piotr Pysz; Michał Kozłowski; Wojciech Wojakowski; Grzegorz Smolka
Journal:  J Cardiovasc Magn Reson       Date:  2021-03-22       Impact factor: 5.364

5.  Case report: Paravalvular regurgitation post transcatheter aortic valve replacement: When in doubt choose cardiac magnetic resonance.

Authors:  Michael B Hadley; Francesca Romana Prandi; Francesco Barillà; Samin Sharma; Annapoorna Kini; Stamatios Lerakis
Journal:  Front Cardiovasc Med       Date:  2022-08-23

6.  Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.

Authors:  W Tanis; R P J Budde; I A C van der Bilt; B Delemarre; G Hoohenkerk; J-K van Rooden; A M Scholtens; J Habets; S Chamuleau
Journal:  Neth Heart J       Date:  2016-02       Impact factor: 2.380

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.