Literature DB >> 16081908

Evaluation of the VACUTAINER PPT Plasma Preparation Tube for use with the Bayer VERSANT assay for quantification of human immunodeficiency virus type 1 RNA.

Tarek Elbeik1, Patricia Nassos, Patricia Kipnis, Barbara Haller, Valerie L Ng.   

Abstract

Separation and storage of plasma within 2 h of phlebotomy is required for the VACUTAINER PPT Plasma Preparation Tube (PPT) versus 4 h for the predecessor VACUTAINER EDTA tube for human immunodeficiency virus type 1 (HIV-1) viral load (HIVL) testing by the VERSANT HIV-1 RNA 3.0 assay (branched DNA). The 2-h limit for PPT imposes time constraints for handling and transporting to the testing laboratory. This study compares HIVL reproducibility from matched blood in EDTA tubes and PPTs and between PPT pairs following processing within 4 h of phlebotomy, stability of plasma HIV-1 RNA at 24- and 72-h room temperature storage in the tube, and comparative labor and supply requirements. Blood from 159 patients was collected in paired tubes (EDTA/PPT or PPT/PPT): 86 paired EDTA tubes and PPTs were processed 4 h following phlebotomy and their HIVLs were compared, 42 paired PPT/PPT pairs were analyzed for intertube HIVL reproducibility, and 31 PPT/PPT pairs were analyzed for HIV-1 RNA stability by HIVL. Labor and supply requirements were compared between PPT and EDTA tubes. PPTs produce results equivalent to standard EDTA tube results when processed 4 h after phlebotomy. PPT intertube analyte results are reproducible. An average decrease of 13% and 37% in HIVL was observed in PPT plasma after 24 and 72 h of room temperature storage, respectively; thus, plasma can be stored at room temperature up to 24 h in the original tube. PPTs offer labor and supply savings over EDTA tubes.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16081908      PMCID: PMC1233973          DOI: 10.1128/JCM.43.8.3769-3771.2005

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  A branched DNA signal amplification assay for quantification of nucleic acid targets below 100 molecules/ml.

Authors:  M L Collins; B Irvine; D Tyner; E Fine; C Zayati; C Chang; T Horn; D Ahle; J Detmer; L P Shen; J Kolberg; S Bushnell; M S Urdea; D D Ho
Journal:  Nucleic Acids Res       Date:  1997-08-01       Impact factor: 16.971

2.  Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

Authors:  M Holodniy; L Rainen; S Herman; B Yen-Lieberman
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

3.  Comparing two methods of clinical measurement: a personal history.

Authors:  J M Bland; D G Altman
Journal:  Int J Epidemiol       Date:  1995       Impact factor: 7.196

4.  Multicenter evaluation of the Bayer VERSANT HIV-1 RNA 3.0 assay: analytical and clinical performance.

Authors:  Curt A Gleaves; John Welle; Mary Campbell; Tarek Elbeik; Valerie Ng; Patricia E Taylor; Ken Kuramoto; Sherri Aceituno; Eva Lewalski; Barbara Joppa; Lynette Sawyer; Carl Schaper; Denise McNairn; Thomas Quinn
Journal:  J Clin Virol       Date:  2002-08       Impact factor: 3.168

5.  Comparative stabilities of quantitative human immunodeficiency virus RNA in plasma from samples collected in VACUTAINER CPT, VACUTAINER PPT, and standard VACUTAINER tubes.

Authors:  M Holodniy; L Mole; B Yen-Lieberman; D Margolis; C Starkey; R Carroll; T Spahlinger; J Todd; J B Jackson
Journal:  J Clin Microbiol       Date:  1995-06       Impact factor: 5.948

  5 in total
  6 in total

1.  Evaluation of effect of specimen-handling parameters for plasma preparation tubes on viral load measurements obtained by using the Abbott RealTime HIV-1 load assay.

Authors:  Helen Fernandes; Svetlana Morosyuk; Klara Abravaya; Madhuri Ramanathan; Lynne Rainen
Journal:  J Clin Microbiol       Date:  2010-05-19       Impact factor: 5.948

Review 2.  Using Epstein-Barr viral load assays to diagnose, monitor, and prevent posttransplant lymphoproliferative disorder.

Authors:  Margaret L Gulley; Weihua Tang
Journal:  Clin Microbiol Rev       Date:  2010-04       Impact factor: 26.132

3.  Coamplification of HIV-1 proviral DNA and viral RNA in assays used for quantification of HIV-1 RNA.

Authors:  H Wan; A Seth; L Rainen; H Fernandes
Journal:  J Clin Microbiol       Date:  2010-02-24       Impact factor: 5.948

4.  Monitoring HIV viral load in resource limited settings: still a matter of debate?

Authors:  Mireia Arnedo; Elena Alonso; Nell Eisenberg; Laura Ibáñez; Cecilia Ferreyra; Angels Jaén; Laurence Flevaud; Samuel Khamadi; Paul Roddy; Jose Maria Gatell; David Dalmau
Journal:  PLoS One       Date:  2012-12-06       Impact factor: 3.240

5.  Individualized Mutation Detection in Circulating Tumor DNA for Monitoring Colorectal Tumor Burden Using a Cancer-Associated Gene Sequencing Panel.

Authors:  Kei A Sato; Tsuyoshi Hachiya; Takeshi Iwaya; Kohei Kume; Teppei Matsuo; Keisuke Kawasaki; Yukito Abiko; Risaburo Akasaka; Takayuki Matsumoto; Koki Otsuka; Satoshi S Nishizuka
Journal:  PLoS One       Date:  2016-01-04       Impact factor: 3.240

6.  Systematic review of the accuracy of plasma preparation tubes for HIV viral load testing.

Authors:  Robert Luo; Jessica Markby; Jilian Sacks; Lara Vojnov
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.