Evaluation of effect of specimen-handling parameters for plasma preparation tubes on viral load measurements obtained by using the Abbott RealTime HIV-1 load assay.

Helen Fernandes1, Svetlana Morosyuk, Klara Abravaya, Madhuri Ramanathan, Lynne Rainen.   

Abstract

HIV-1 viral load testing is essential to the management of HIV-1-infected patients, and proper specimen handling ensures accurate viral load (VL) results. This study was performed to (i) evaluate the effect of freezing plasma in situ in BD Vacutainer plasma preparation tubes (PPT) on the accuracy of HIV-1 viral load results using the Abbott RealTime HIV-1 assay and (ii) evaluate the effect of whole-blood storage in the PPT for 6 h at room temperature prior to centrifugation (PPT6H) rather than 2 h as specified in the PPT product insert. Of the 64 HIV-positive subjects evaluated, 29 had average viral load counts of >40 copies/ml in at least one of the tubes tested and 35 subjects had a result of either "undetected target" or "below the limit of quantification" (LOQ) for all or some of the tubes regardless of handling condition. For the 29 subjects with VLs that were >LOQ, the mean biases between plasma from Vacutainer K(2)EDTA tubes and plasma frozen in situ in PPT and between K(2)EDTA tube plasma and plasma from PPT6H (log(10) copies/ml) were 0.005 and -0.001, respectively, and r(2) was >0.92 for all correlations. We conclude that VLs determined from plasma frozen in situ in PPT are equivalent to VLs in K(2)EDTA tube plasma and can be used for accurate quantification of HIV-1 RNA in the Abbott RealTime HIV-1 assay. Furthermore specimens collected in PPT can be stored for 6 h at room temperature with no effect on viral load results as measured by the Abbott RealTime HIV-1 assay.

Entities:  

Mesh:

Year:  2010        PMID: 20484602      PMCID: PMC2897535          DOI: 10.1128/JCM.00083-10

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Platelets may affect detection and quantitation of HIV RNA in plasma samples with low viral loads.

Authors:  Ester Cerdeira Sabino; Nelson Gaburo; José Paulo Leite; Mauricio Viecili; Luiz Gastão Rosenfeld
Journal:  J Acquir Immune Defic Syndr       Date:  2004-11-01       Impact factor: 3.731

2.  Evaluation of the VACUTAINER PPT Plasma Preparation Tube for use with the Bayer VERSANT assay for quantification of human immunodeficiency virus type 1 RNA.

Authors:  Tarek Elbeik; Patricia Nassos; Patricia Kipnis; Barbara Haller; Valerie L Ng
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

3.  Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

Authors:  M Holodniy; L Rainen; S Herman; B Yen-Lieberman
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

4.  Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.

Authors:  Hossein Salimnia; Ellen C Moore; Lawrence R Crane; Rodger D Macarthur; Marilynn R Fairfax
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

5.  Coamplification of HIV-1 proviral DNA and viral RNA in assays used for quantification of HIV-1 RNA.

Authors:  H Wan; A Seth; L Rainen; H Fernandes
Journal:  J Clin Microbiol       Date:  2010-02-24       Impact factor: 5.948

Review 6.  HIV-1 load quantitation: a 17-year perspective.

Authors:  Mark Holodniy
Journal:  J Infect Dis       Date:  2006-09-15       Impact factor: 5.226

7.  Transient viremia in HIV-infected patients and use of plasma preparation tubes.

Authors:  Valentina Stosor; Frank J Palella; Baiba Berzins; Michele Till; Angel Leake; Joan S Chmiel; Robert L Murphy
Journal:  Clin Infect Dis       Date:  2005-10-21       Impact factor: 9.079

8.  Comparison of once-daily atazanavir with efavirenz, each in combination with fixed-dose zidovudine and lamivudine, as initial therapy for patients infected with HIV.

Authors:  Kathleen Squires; Adriano Lazzarin; José M Gatell; William G Powderly; Vadim Pokrovskiy; Jean-François Delfraissy; Joseph Jemsek; Antonio Rivero; Willy Rozenbaum; Shannon Schrader; Michael Sension; Asda Vibhagool; Alexandra Thiry; Michael Giordano
Journal:  J Acquir Immune Defic Syndr       Date:  2004-08-15       Impact factor: 3.731

9.  Increased detectability of plasma HIV-1 RNA after introduction of a new assay and altered specimen-processing procedures.

Authors:  Peter F Rebeiro; Asghar Kheshti; Sally S Bebawy; Samuel E Stinnette; Husamettin Erdem; Yi-Wei Tang; Timothy R Sterling; Stephen P Raffanti; Richard T D'Aquila
Journal:  Clin Infect Dis       Date:  2008-11-15       Impact factor: 9.079

10.  Elevation of viral load by PCR and use of plasma preparation tubes for quantification of human immunodeficiency virus type 1.

Authors:  S García-Bujalance; C Ladrón de Guevara; J González-García; J R Arribas; F Zamora; A Gutiérrez
Journal:  J Microbiol Methods       Date:  2007-02-07       Impact factor: 2.363

View more
  4 in total

1.  Analytical variables influencing the HCV RNA determination by TaqMan real-time PCR in routine clinical laboratory practice.

Authors:  Abida Raza; Zameer Ali; Javaid Irfan; Shahnaz Murtaza; Samina Shakeel
Journal:  Mol Biol Rep       Date:  2012-02-12       Impact factor: 2.316

2.  Effect of sample management on quantitative HIV-1 viral load measurement at Saint Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia.

Authors:  Gadissa Gutema; Habtyes Hailu; Belete W/Semeyat; Amelework Yilma; Saro Abdela; Eleni Kidane; Sisay Adane; Mengistu Yimer; Aster Tsegaye
Journal:  PLoS One       Date:  2022-06-14       Impact factor: 3.752

3.  Field evaluation of HIV-1 viral load monitoring in adults and children receiving antiretroviral treatment in Nigeria by dried blood spot testing with RealTime HIV-1 on m2000.

Authors:  Monday Tola; Ramadhani O Habib; Adebajo Sylvia; Trevor A Crowell; Nowak G Rebecca; Manhattan E Charurat; Patrick Dakum; Nicaise Ndembi
Journal:  J Clin Virol       Date:  2020-11-25       Impact factor: 14.481

4.  Systematic review of the accuracy of plasma preparation tubes for HIV viral load testing.

Authors:  Robert Luo; Jessica Markby; Jilian Sacks; Lara Vojnov
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.