Literature DB >> 10618109

Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

M Holodniy1, L Rainen, S Herman, B Yen-Lieberman.   

Abstract

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas obtained from PPT tubes stored and shipped under nine different conditions were compared to conventional EDTA tube plasmas stored at -70 degrees C within 2 h after phlebotomy. Compared to viral loads in frozen EDTA plasma, those in PPT tube plasma that was frozen immediately and either separated or shipped in situ were not significantly different. Viral loads in PPT tube plasma after storage for 6 h at either room temperature or 4 degrees C, followed by shipment at ambient temperature or on wet or dry ice, were not significantly different from baseline viral loads in EDTA or PPT plasma. The results of this study indicate that the HIV load in PPT tube plasma is equivalent to that in standard EDTA plasma. Plasma viral load is not affected by storage or shipment temperature when plasma is collected in PPT tubes. Furthermore, plasmas can be shipped in spun PPT tubes, and the tubes provide a safer and more convenient method for sample collection and transport than regular EDTA tubes.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10618109      PMCID: PMC88717          DOI: 10.1128/JCM.38.1.323-326.2000

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  17 in total

1.  Longitudinal serum HIV RNA quantification: correlation to viral phenotype at seroconversion and clinical outcome.

Authors:  T L Katzenstein; C Pedersen; C Nielsen; J D Lundgren; P H Jakobsen; J Gerstoft
Journal:  AIDS       Date:  1996-02       Impact factor: 4.177

2.  Comparative evaluation of NASBA HIV-1 RNA QT, AMPLICOR-HIV monitor, and QUANTIPLEX HIV RNA assay, three methods for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  H Revets; D Marissens; S de Wit; P Lacor; N Clumeck; S Lauwers; G Zissis
Journal:  J Clin Microbiol       Date:  1996-05       Impact factor: 5.948

3.  Changes in plasma HIV RNA levels and CD4+ lymphocyte counts predict both response to antiretroviral therapy and therapeutic failure. VA Cooperative Study Group on AIDS.

Authors:  W A O'Brien; P M Hartigan; E S Daar; M S Simberkoff; J D Hamilton
Journal:  Ann Intern Med       Date:  1997-06-15       Impact factor: 25.391

4.  Comparing methods of measurement: why plotting difference against standard method is misleading.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1995-10-21       Impact factor: 79.321

5.  Diurnal and short-term stability of HIV virus load as measured by gene amplification.

Authors:  M Holodniy; L Mole; M Winters; T C Merigan
Journal:  J Acquir Immune Defic Syndr (1988)       Date:  1994-04

6.  The relation of virologic and immunologic markers to clinical outcomes after nucleoside therapy in HIV-infected adults with 200 to 500 CD4 cells per cubic millimeter. AIDS Clinical Trials Group Study 175 Virology Study Team.

Authors:  D A Katzenstein; S M Hammer; M D Hughes; H Gundacker; J B Jackson; S Fiscus; S Rasheed; T Elbeik; R Reichman; A Japour; T C Merigan; M S Hirsch
Journal:  N Engl J Med       Date:  1996-10-10       Impact factor: 91.245

7.  Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS.

Authors:  W A O'Brien; P M Hartigan; D Martin; J Esinhart; A Hill; S Benoit; M Rubin; M S Simberkoff; J D Hamilton
Journal:  N Engl J Med       Date:  1996-02-15       Impact factor: 91.245

Review 8.  Measuring viral load in the clinical setting.

Authors:  R Harrigan
Journal:  J Acquir Immune Defic Syndr Hum Retrovirol       Date:  1995

9.  Prognosis in HIV-1 infection predicted by the quantity of virus in plasma.

Authors:  J W Mellors; C R Rinaldo; P Gupta; R M White; J A Todd; L A Kingsley
Journal:  Science       Date:  1996-05-24       Impact factor: 47.728

10.  Biological variation and quality control of plasma human immunodeficiency virus type 1 RNA quantitation by reverse transcriptase polymerase chain reaction.

Authors:  M A Winters; L B Tan; D A Katzenstein; T C Merigan
Journal:  J Clin Microbiol       Date:  1993-11       Impact factor: 5.948

View more
  8 in total

1.  Evaluation of effect of specimen-handling parameters for plasma preparation tubes on viral load measurements obtained by using the Abbott RealTime HIV-1 load assay.

Authors:  Helen Fernandes; Svetlana Morosyuk; Klara Abravaya; Madhuri Ramanathan; Lynne Rainen
Journal:  J Clin Microbiol       Date:  2010-05-19       Impact factor: 5.948

2.  Evaluation of the VACUTAINER PPT Plasma Preparation Tube for use with the Bayer VERSANT assay for quantification of human immunodeficiency virus type 1 RNA.

Authors:  Tarek Elbeik; Patricia Nassos; Patricia Kipnis; Barbara Haller; Valerie L Ng
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

3.  Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.

Authors:  Hossein Salimnia; Ellen C Moore; Lawrence R Crane; Rodger D Macarthur; Marilynn R Fairfax
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

4.  Effect of sample management on quantitative HIV-1 viral load measurement at Saint Paul's Hospital Millennium Medical College, Addis Ababa, Ethiopia.

Authors:  Gadissa Gutema; Habtyes Hailu; Belete W/Semeyat; Amelework Yilma; Saro Abdela; Eleni Kidane; Sisay Adane; Mengistu Yimer; Aster Tsegaye
Journal:  PLoS One       Date:  2022-06-14       Impact factor: 3.752

5.  Overestimation of human immunodeficiency virus type 1 load caused by the presence of cells in plasma from plasma preparation tubes.

Authors:  Anne-Marte Bakken Kran; Tom Øystein Jonassen; Mette Sannes; Kirsti Jakobsen; Andreas Lind; Arild Maeland; Mona Holberg-Petersen
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

6.  A nonparametric likelihood test for detecting discordance between two measurements with application to censored viral load determinations.

Authors:  Zonghui Hu; Dean Follmann; Jing Qin; Robin L Dewar; Phumelele Sangweni
Journal:  Stat Med       Date:  2008-09-30       Impact factor: 2.373

7.  A robust HIV-1 viral load detection assay optimized for Indian sub type C specific strains and resource limiting setting.

Authors:  Arpan Acharya; Salil Vaniawala; Parth Shah; Harsh Parekh; Rabindra Nath Misra; Minal Wani; Pratap N Mukhopadhyaya
Journal:  Biol Res       Date:  2014-05-30       Impact factor: 5.612

8.  Systematic review of the accuracy of plasma preparation tubes for HIV viral load testing.

Authors:  Robert Luo; Jessica Markby; Jilian Sacks; Lara Vojnov
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.