Literature DB >> 11042643

Placement of an inferior vena cava filter in a pig guided by high-resolution MR fluoroscopy at 1.5 T.

L W Bartels1, C Bos, R van Der Weide, H F Smits, C J Bakker, M A Viergever.   

Abstract

Percutaneous placement of an inferior vena cava filter is a means for long-term prevention of pulmonary thromboembolism. In this study we investigated the magnetic resonance (MR) imaging properties of a Nitinol vena cava filter, in various anatomic and angiographic scans, as well as the feasibility of placing this filter under near real-time, high-resolution MR fluoroscopy. We made use of the passive tracking strategy, with on-line image processing and visualization, both in vitro and in a pig. The artifacts provoked by the metallic filter were such that the position and orientation of the filter were well depicted in all scans. Considerable radiofrequency caging obscured the interior of the filter. Our experiments showed that an MR-guided vena cava filter placement, with sufficient temporal and spatial resolution, is possible. Three-dimensional phase contrast MRA allowed direct evaluation of the filter placement procedure, without the use of contrast agent. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11042643     DOI: 10.1002/1522-2586(200010)12:4<599::aid-jmri13>3.0.co;2-7

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  11 in total

1.  Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

Authors:  Robert J Lederman; Michael A Guttman; Dana C Peters; Richard B Thompson; Jonathan M Sorger; Alexander J Dick; Venkatesh K Raman; Elliot R McVeigh
Journal:  Circulation       Date:  2002-03-19       Impact factor: 29.690

Review 2.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

Review 3.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

4.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 5.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

6.  Real-time MRI guided atrial septal puncture and balloon septostomy in swine.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Ranil Desilva; Ronnier J Aviles; Victor J Wright; William H Schenke; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2006-04       Impact factor: 2.692

7.  Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model.

Authors:  Amish N Raval; Parag V Karmarkar; Michael A Guttman; Cengizhan Ozturk; Smita Sampath; Ranil DeSilva; Ronnier J Aviles; Minnan Xu; Victor J Wright; William H Schenke; Ozgur Kocaturk; Alexander J Dick; Venkatesh K Raman; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2006-02-20       Impact factor: 29.690

8.  Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in Swine.

Authors:  Amish N Raval; James D Telep; Michael A Guttman; Cengizhan Ozturk; Michael Jones; Richard B Thompson; Victor J Wright; William H Schenke; Ranil DeSilva; Ronnier J Aviles; Venkatesh K Raman; Michael C Slack; Robert J Lederman
Journal:  Circulation       Date:  2005-07-25       Impact factor: 29.690

9.  Thin film based semi-active resonant marker design for low profile interventional cardiovascular MRI devices.

Authors:  Engin Baysoy; Dursun Korel Yildirim; Cagla Ozsoy; Senol Mutlu; Ozgur Kocaturk
Journal:  MAGMA       Date:  2016-09-07       Impact factor: 2.310

Review 10.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10
View more