Literature DB >> 11854130

Magnetic resonance--guided coronary artery stent placement in a swine model.

Elmar Spuentrup1, Alexander Ruebben, Tobias Schaeffter, Warren J Manning, Rolf W Günther, Arno Buecker.   

Abstract

BACKGROUND: Magnetic resonance (MR)--guided coronary artery stent placement is a challenging vascular intervention because of the small size of the coronary arteries combined with incessant motion during the respiratory and cardiac cycles. These obstacles necessitate higher temporal and higher spatial resolution real-time MR imaging techniques when compared with interventional peripheral MR angiography. METHODS AND
RESULTS: A new, ultrafast, real-time MR imaging technique that combines steady-state free precession (SSFP) for high signal-to-noise ratio and radial k-space sampling (rSSFP) for motion artifact suppression was implemented on a 1.5-T clinical whole-body interventional MR scanner. The sliding window reconstruction technique yielded a frame rate of 15/s allowing for data acquisition during free breathing and without cardiac triggering. Eleven balloon-expandable stainless steel coronary stents were placed in both coronary arteries of 7 pigs (40 to 70 kg body weight) using a nitinol guidewire and passive device visualization. Position of the coronary stents was controlled by a navigator-gated free-breathing ECG-triggered three-dimensional SSFP coronary MRA sequence and confirmed visually on the ex vivo heart. The presented real-time MR imaging sequence reliably allowed for high-quality coronary MR fluoroscopy without motion artifacts in all pigs. Ten of 11 coronary stents were correctly placed under MR guidance. One stent dislodged proximally from the left main coronary artery because of too-small balloon size. Stent dislocation was correctly predicted during real-time MR imaging.
CONCLUSION: The presented approach allows for real-time MR-guided coronary artery stent placement in a swine model.

Entities:  

Mesh:

Year:  2002        PMID: 11854130     DOI: 10.1161/hc0702.104165

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  33 in total

Review 1.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

2.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 3.  Magnetic resonance imaging of coronary atherosclerosis.

Authors:  Zahi A Fayad; Robin P Choudhury; Valentin Fuster
Journal:  Curr Atheroscler Rep       Date:  2003-09       Impact factor: 5.113

4.  MR-guided catheter navigation of the intracranial subarachnoid space.

Authors:  George Rappard; Gregory J Metzger; James L Fleckenstein; Evelyn E Babcock; Paul T Weatherall; Robert E Replogle; G Lee Pride; Susan L Miller; Christina E Adams; Phillip D Purdy
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

5.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

Review 6.  The future of real-time cardiac magnetic resonance imaging.

Authors:  Krishna S Nayak; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

7.  Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine.

Authors:  Jordin D Green; Reed A Omary; Brian E Schirf; Richard Tang; Biao Lu; James A Gehl; J Jenny Huang; James C Carr; F Scott Pereles; Debiao Li
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

Review 8.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

Review 9.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

Review 10.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.