Literature DB >> 16018748

Resonance frequency analysis of one-stage dental implant stability during the osseointegration period.

S Ersanli1, C Karabuda, F Beck, B Leblebicioglu.   

Abstract

BACKGROUND: Currently, there is no available clinical tool to evaluate the amount of osseointegration and stability around dental implants. It has been recently suggested that changes in the stiffness of an implant in bone during healing may be monitored by using resonance frequency analysis (RFA). The aim of this study was to determine whether RFA can be integrated into the routine clinical evaluation of initial healing of dental implants.
METHODS: Thirty-one patients (18 female and 13 male; mean age of 51.7 years) were included into this study. A total of 122 implants and three different, but comparable, implant designs were evaluated by using RFA. The specific transducer for each implant system was used. ISQ (implant stability quotient) readings were obtained for each implant at the time of surgery, 3 and 6 weeks postoperatively, and at the time of loading (3 or 6 months following surgery). Data were analyzed for different healing times, various anatomical locations, implant length, and type. Average time in function was 12 months.
RESULTS: Two implants failed during healing. Implant stability was higher on the mandible compared to the maxilla for each implant system studied (Mann-Whitney test, P <0.01). ISQ readings decreased significantly at 3 and 6 weeks post-surgery compared to readings obtained at surgery (Wilcoxon matched pairs sign-rank tests, P <0.01). A recovery to the initial ISQ levels was noted at the time of implant loading. The possible effects of different types and lengths of implants to ISQ readings were examined.
CONCLUSIONS: Results of this study support the need for a clinical tool to evaluate dental implant stability prior to loading, especially for implants placed in the maxilla. It appears that implant stability is weakest at 3 to 6 weeks in one-stage non-loaded dental implants. ISQ readings can be used to determine different healing phases and the stability of dental implants. However, it is difficult to define a general standardized range of ISQ readings for successful implant integration for various implant systems. Thus, RFA values/ISQ levels should be calibrated for each implant system separately. Further studies are needed to compare the early changes seen in immediately loaded dental implants and to determine whether there is any time in which the total recovery in ISQ levels may occur.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16018748     DOI: 10.1902/jop.2005.76.7.1066

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  27 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

2.  Immediate vs non-immediate loading post-extractive implants: a comparative study of implant stability quotient (ISQ).

Authors:  L Milillo; C Fiandaca; F Giannoulis; L Ottria; A Lucchese; F Silvestre; M Petruzzi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

Review 3.  Implants in bone: part I. A current overview about tissue response, surface modifications and future perspectives.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-24

4.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

5.  Assessment of implant stability following sinus lift procedures with different grafting materials.

Authors:  Damir Jelušić; Ivan Puhar; Darije Plančak
Journal:  Acta Stomatol Croat       Date:  2014-03

6.  The evaluation of prepared microgroove pattern by femtosecond laser on alumina-zirconia nano-composite for endosseous dental implant application.

Authors:  Moluk Aivazi; Mohammad Hossein Fathi; Farahnaz Nejatidanesh; Vajihesadat Mortazavi; Batoul HashemiBeni; Jukka Pekka Matinlinna; Omid Savabi
Journal:  Lasers Med Sci       Date:  2016-09-28       Impact factor: 3.161

7.  The effects of elevated hemoglobin A(1c) in patients with type 2 diabetes mellitus on dental implants: Survival and stability at one year.

Authors:  Thomas W Oates; Patrick Galloway; Peggy Alexander; Adriana Vargas Green; Guy Huynh-Ba; Jocelyn Feine; C Alex McMahan
Journal:  J Am Dent Assoc       Date:  2014-12       Impact factor: 3.634

8.  Stability changes of miniscrew implants over time.

Authors:  Derid S Ure; Donald R Oliver; Ki Beom Kim; Ana Cláudia Melo; Peter H Buschang
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

9.  Peri-implant versus periodontal wound healing.

Authors:  Pinar Emecen-Huja; Tim D Eubank; Vladimir Shapiro; Vedat Yildiz; Dimitris N Tatakis; Binnaz Leblebicioglu
Journal:  J Clin Periodontol       Date:  2013-06-18       Impact factor: 8.728

10.  The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period.

Authors:  Mohammed Jasim Al-Juboori; Shafluzan Bin AbdulRahaman
Journal:  Open Dent J       Date:  2015-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.