Literature DB >> 25698473

Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.

Laurent Dercle1, Monia Ouali, Pierre Pascal, Thomas Giraudmaillet, Roland Chisin, Olivier Lairez, Marie-Agnès Marachet, Hervé Rousseau, Delphine Bastié, Fayçal Ben Bouallègue, Isabelle Berry.   

Abstract

BACKGROUND: Gated blood pool SPECT (GBPS) requires further validation for the assessment of the right ventricle (RV). This study evaluated three algorithms: BP-SPECT, QBS, and TOMPOOL (results are referred using this order). We compared (1) their "quantitative-accuracy": estimation of RV ejection fraction (EF), end-diastolic volume (EDV), and cardiac output (CO); (2) their "qualitative-accuracy": threshold values allowing diagnosing an impairment of the RV function; (3) their reproducibility: inter-observer relative variability (IOV). METHODS AND
RESULTS: Forty-eight consecutive patients underwent GBPS. Recommended reference standards were used: cardiac magnetic resonance imaging (CMR) (EDV, EF, n = 48), catheter measurements from thermodilution (TD) (CO, n = 25). (1) "Quantitative-accuracy": r = 0.42, 0.30, 0.42 for RVEF (CMR); r = 0.69, 0.77, 0.53 for RVEDV (CMR); 0.32, 0.36, 0.52 for RCO (TD). (2) "Qualitative-accuracy": optimal thresholds were 54.7%, 38.5%, 45.2% (AUC: 0.83, 0.80, 0.79) for RVEF; 229, 180, 94 mL (AUC: 0.83, 0.81, 0.81) for RVEDV; 4.1, 4.4, 2.6 L·minute(-1) (AUC: 0.73, 0.77, 0.80) for RCO. (3) Reproducibility: IOV was 5% ± 6%, 8% ± 12%, 17% ± 18% for RVEF; 6% ± 8%, 4% ± 4%, 21% ± 18% for RVEDV; 8% ± 8%, 11% ± 15%, 24% ± 20% for RCO.
CONCLUSION: Diagnostic accuracies are similar. A CMR-based calibration is required for a quantitative-analysis (cautious interpretation) or an accurate qualitative analysis (thresholds must be adjusted). Automatic procedures (BP-SPECT, QBS) offer the best compromise accuracy/reproducibility.

Entities:  

Mesh:

Year:  2015        PMID: 25698473     DOI: 10.1007/s12350-014-0062-7

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  36 in total

1.  MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study.

Authors:  J Barkhausen; S G Ruehm; M Goyen; T Buck; G Laub; J F Debatin
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.

Authors:  D Daou; F Harel; B O Helal; T Fourme; P Colin; R Lebtahi; D Mariano-Goulart; M Faraggi; M Slama; D Le Guludec
Journal:  J Nucl Med       Date:  2001-07       Impact factor: 10.057

Review 3.  Right ventricular function in cardiovascular disease, part I: Anatomy, physiology, aging, and functional assessment of the right ventricle.

Authors:  François Haddad; Sharon A Hunt; David N Rosenthal; Daniel J Murphy
Journal:  Circulation       Date:  2008-03-18       Impact factor: 29.690

4.  Comparative study of quantitative blood pool SPECT imaging with 180 degrees and 360 degrees acquisition orbits on accuracy of cardiac function.

Authors:  Itaru Adachi; Tatsuya Umeda; Hiroaki Shimomura; Michihiro Suwa; Tsuyoshi Komori; Yasuharu Ogura; Keita Utsunomiya; Yasushi Kitaura; Isamu Narabayashi
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

5.  Normal limits of gated blood pool SPECT count-based regional cardiac function parameters.

Authors:  Kenneth J Nichols; Andrew Van Tosh; Pieter De Bondt; Steven R Bergmann; Christopher J Palestro; Nathaniel Reichek
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-31       Impact factor: 2.357

6.  Is TOMPOOL (gated blood-pool SPECT processing software) accurate to diagnose right and left ventricular dysfunction in a clinical setting?

Authors:  Laurent Dercle; Thomas Giraudmaillet; Pierre Pascal; Olivier Lairez; Roland Chisin; Marie-Agnès Marachet; Monia Ouali; Hervé Rousseau; Delphine Bastié; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2014-05-30       Impact factor: 5.952

7.  Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Antoine Micheau; Hélène Vernhet-Kovacsik; Denis Mariano-Goulart
Journal:  Nucl Med Commun       Date:  2011-02       Impact factor: 1.690

8.  Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles.

Authors:  Olakunle Akinboboye; Kenneth Nichols; Yi Wang; Uzodinma R Dim; Nathaniel Reichek
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

9.  Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

10.  Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging.

Authors:  Theano Papavassiliu; Harald P Kühl; Meike Schröder; Tim Süselbeck; Olga Bondarenko; Christoph K Böhm; Aernout Beek; Mark M B Hofman; Albert C van Rossum
Journal:  Radiology       Date:  2005-06-13       Impact factor: 11.105

View more
  3 in total

1.  RV function improvement following nitric oxide inhalation demonstrated by gated blood pool SPECT in a patient with primary pulmonary hypertension.

Authors:  Fayçal Ben Bouallègue; Fabien Vauchot; Aurélie Bourdon; Meriem Benkiran; Clément Boissin; Jérémy Charriot; Arnaud Bourdin; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2018-01-10       Impact factor: 5.952

Review 2.  Perioperative right ventricular function and dysfunction in adult cardiac surgery-focused review (part 1-anatomy, pathophysiology, and diagnosis).

Authors:  Praveen Kerala Varma; Reshmi Liza Jose; Neethu Krishna; Balaji Srimurugan; George Jose Valooran; Aveek Jayant
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-10-27

3.  Heart Rate Expenditure Correlates with Right Ventricular Function.

Authors:  Daniel J Lachant; Allison N Light; Maria L Mackin; Ronald G Schwartz; R James White
Journal:  Ann Am Thorac Soc       Date:  2020-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.