Literature DB >> 12679390

Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure.

Graham A Wright1, Simon Thackray, Syd Howey, John G Cleland.   

Abstract

UNLABELLED: Gated blood-pool SPECT (GBPS) has several potential advantages over planar radionuclide ventriculography (PRNV), including the possibility of greater repeatability of left ventricular ejection fraction (LVEF) and the noninvasive calculation of left ventricular end-systolic volume and left ventricular end-diastolic volume (LVEDV). The aim of this study was to assess the repeatability of LVEF and LVEDV from GBPS and to compare LVEF with those from PRNV.
METHODS: Fifty patients underwent PRNV and GBPS, 23 of whom also had repeated studies in the same session. GPBS studies were processed using the Cedars Sinai Quantitative Blood-Pool SPECT (QBS) software that automatically calculates LVEF and LVEDV. Automatic processing with QBS was successful in 70% of the GBPS studies, with the remaining studies processed using the manual option in QBS. All PRNV studies were processed using a manual processing technique.
RESULTS: Comparison of LVEF from PRNV and GBPS yielded a correlation coefficient of 0.80. Bland-Altman analysis demonstrated a mean difference of 0.74% +/- 7.62% (mean +/- SD) between LVEF from the 2 techniques. The 95% limits of agreement are therefore -14.50% to +15.98%. The correlation between repeated measurements was 0.87 for GBPS and 0.95 for PRNV. Bland-Altman analysis revealed poorer repeatability for GBPS (95% limits of agreement, -9.63% to +14.97% vs. -4.66% to +5.92%; P = 0.003). The mean LVEDV was 198 +/- 94 mL, with a mean difference of 9 +/- 47 mL between repeated measurements. The 95% limits of agreement are therefore -85 to +103 mL.
CONCLUSION: GBPS provides a less repeatable measurement of LVEF than PRNV. Repeatability of LVEDV measurements from GBPS is poor.

Entities:  

Mesh:

Year:  2003        PMID: 12679390

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  15 in total

1.  Model dependence of gated blood pool SPECT ventricular function measurements.

Authors:  Kenneth Nichols; Naeem Humayun; Pieter De Bondt; Stijn Vandenberghe; Olakunle O Akinboboye; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

2.  Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography.

Authors:  Marcus Hacker; Xaver Hoyer; Sandra Kupzyk; Christian La Fougere; Johann Kois; Hans-Ulrich Stempfle; Reinhold Tiling; Klaus Hahn; Stefan Störk
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

Review 3.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

4.  Gated tomographic radionuclide angiography using cadmium-zinc-telluride detector gamma camera; comparison to traditional gamma cameras.

Authors:  Maria Maj Jensen; Ulla Schmidt; Chenxi Huang; Bo Zerahn
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

5.  Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles.

Authors:  Olakunle Akinboboye; Kenneth Nichols; Yi Wang; Uzodinma R Dim; Nathaniel Reichek
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

6.  Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

7.  Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim; Yong Beom Shin; Dong-Soo Kim
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

8.  A prospective evaluation of the repeatability of left ventricular ejection fraction measurement by gated SPECT.

Authors:  Dustin Kliner; Li Wang; Daniel Winger; William P Follansbee; Prem Soman
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

9.  Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function.

Authors:  Doumit Daou; Carlos Coaguila; Abdel Benada
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

10.  Assessment of an intermediate reprojection technique transitioning from planar to SPECT radionuclide ventriculography.

Authors:  Jim O'Doherty; Bruno Rojas Fisher; Jonathan Mark Price; Kshama Wechalekar
Journal:  J Nucl Cardiol       Date:  2014-08-01       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.