Literature DB >> 15978692

Controlled release of anti-inflammatory agent alpha-MSH from neural implants.

Yinghui Zhong1, Ravi V Bellamkonda.   

Abstract

Si-multi-electrode arrays implanted into brain tissue for long-term recording lose electrical connectivity due to the post-implantation inflammatory reaction. This inflammatory reaction creates a physical and electrical gap between the electrode and the surrounding neurons. In this study, novel nitrocellulose-based coatings were developed for the sustained delivery of the anti-inflammatory neuropeptide alpha-melanocyte stimulating hormone (alpha-MSH). alpha-MSH was incorporated in micron-scale nitrocellulose coatings and slow, sustained release over 21 days was attained in vitro. The alpha-MSH released on day 21 was still bioactive, and successfully inhibited nitric oxide (NO) production by LPS-stimulated microglia. The amount of initial drug loading directly affected the release rate, with higher initial loading increasing the mass released but not the percent of drug released. The surface morphology and thickness of the coatings were examined by scanning electron microscopy (SEM) and profilometry. In addition, impedance measurement showed that the alpha-MSH loaded nitrocellulose coatings reduced the magnitude of electrode impedance at the biologically relevant frequency of 1 kHz. In conclusion, nitrocellulose-based, bioactive coatings that release anti-inflammatory agents without increasing the impedence of the electrode were successfully fabricated. These coatings have the potential to reduce inflammation at the electrode-brain interface in vivo, and facilitate long-term recordings from Si-multi-electrode arrays.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15978692     DOI: 10.1016/j.jconrel.2005.05.012

Source DB:  PubMed          Journal:  J Control Release        ISSN: 0168-3659            Impact factor:   9.776


  46 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

Review 2.  A review of the effects of FSCV and microdialysis measurements on dopamine release in the surrounding tissue.

Authors:  Andrea Jaquins-Gerstl; Adrian C Michael
Journal:  Analyst       Date:  2015-06-07       Impact factor: 4.616

Review 3.  Approaches to neural tissue engineering using scaffolds for drug delivery.

Authors:  Stephanie M Willerth; Shelly E Sakiyama-Elbert
Journal:  Adv Drug Deliv Rev       Date:  2007-04-10       Impact factor: 15.470

4.  Anti-inflammatory polymeric coatings for implantable biomaterials and devices.

Authors:  Amanda W Bridges; Andrés J García
Journal:  J Diabetes Sci Technol       Date:  2008-11

5.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

6.  Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo.

Authors:  Takashi D Y Kozai; Andrea S Jaquins-Gerstl; Alberto L Vazquez; Adrian C Michael; X Tracy Cui
Journal:  Biomaterials       Date:  2016-02-10       Impact factor: 12.479

7.  In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

Authors:  Liangqi Ouyang; Crystal L Shaw; Chin-Chen Kuo; Amy L Griffin; David C Martin
Journal:  J Neural Eng       Date:  2014-02-06       Impact factor: 5.379

8.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

9.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

10.  Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.

Authors:  Christi L Kolarcik; Kasey Catt; Erika Rost; Ingrid N Albrecht; Dennis Bourbeau; Zhanhong Du; Takashi D Y Kozai; Xiliang Luo; Douglas J Weber; X Tracy Cui
Journal:  J Neural Eng       Date:  2014-12-08       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.