Literature DB >> 25485675

Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.

Christi L Kolarcik1, Kasey Catt, Erika Rost, Ingrid N Albrecht, Dennis Bourbeau, Zhanhong Du, Takashi D Y Kozai, Xiliang Luo, Douglas J Weber, X Tracy Cui.   

Abstract

OBJECTIVE: The dorsal root ganglion is an attractive target for implanting neural electrode arrays that restore sensory function or provide therapy via stimulation. However, penetrating microelectrodes designed for these applications are small and deliver low currents. For long-term performance of microstimulation devices, novel coating materials are needed in part to decrease impedance values at the electrode-tissue interface and to increase charge storage capacity. APPROACH: Conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) and multi-wall carbon nanotubes (CNTs) were coated on the electrode surface and doped with the anti-inflammatory drug, dexamethasone. Electrode characteristics and the tissue reaction around neural electrodes as a result of stimulation, coating and drug release were characterized. Hematoxylin and eosin staining along with antibodies recognizing Iba1 (microglia/macrophages), NF200 (neuronal axons), NeuN (neurons), vimentin (fibroblasts), caspase-3 (cell death) and L1 (neural cell adhesion molecule) were used. Quantitative image analyses were performed using MATLAB. MAIN
RESULTS: Our results indicate that coated microelectrodes have lower in vitro and in vivo impedance values. Significantly less neuronal death/damage was observed with coated electrodes as compared to non-coated controls. The inflammatory response with the PEDOT/CNT-coated electrodes was also reduced. SIGNIFICANCE: This study is the first to report on the utility of these coatings in stimulation applications. Our results indicate PEDOT/CNT coatings may be valuable additions to implantable electrodes used as therapeutic modalities.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25485675      PMCID: PMC4433052          DOI: 10.1088/1741-2560/12/1/016008

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  62 in total

1.  Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

Authors:  Rio J Vetter; Justin C Williams; Jamille F Hetke; Elizabeth A Nunamaker; Daryl R Kipke
Journal:  IEEE Trans Biomed Eng       Date:  2004-06       Impact factor: 4.538

2.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

Authors:  T D Y Kozai; T C Marzullo; F Hooi; N B Langhals; A K Majewska; E B Brown; D R Kipke
Journal:  J Neural Eng       Date:  2010-07-19       Impact factor: 5.379

3.  Multi-site incorporation of bioactive matrices into MEMS-based neural probes.

Authors:  Justin C Williams; Matthew M Holecko; Stephen P Massia; Patrick Rousche; Daryl R Kipke
Journal:  J Neural Eng       Date:  2005-11-29       Impact factor: 5.379

Review 4.  Applications of carbon nanotubes in drug delivery.

Authors:  Alberto Bianco; Kostas Kostarelos; Maurizio Prato
Journal:  Curr Opin Chem Biol       Date:  2005-10-17       Impact factor: 8.822

Review 5.  The roles of cell adhesion molecules on the formation of peripheral myelin.

Authors:  Y Takeda; Y Murakami; H Asou; K Uyemura
Journal:  Keio J Med       Date:  2001-12

6.  Functionalized carbon nanotubes are non-cytotoxic and preserve the functionality of primary immune cells.

Authors:  Hélène Dumortier; Stéphanie Lacotte; Giorgia Pastorin; Riccardo Marega; Wei Wu; Davide Bonifazi; Jean-Paul Briand; Maurizio Prato; Sylviane Muller; Alberto Bianco
Journal:  Nano Lett       Date:  2006-07       Impact factor: 11.189

7.  Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortex.

Authors:  Douglas McCreery; Victor Pikov; Philip R Troyk
Journal:  J Neural Eng       Date:  2010-05-11       Impact factor: 5.379

8.  Dexamethasone treatment reduces astroglia responses to inserted neuroprosthetic devices in rat neocortex.

Authors:  L Spataro; J Dilgen; S Retterer; A J Spence; M Isaacson; J N Turner; W Shain
Journal:  Exp Neurol       Date:  2005-08       Impact factor: 5.330

9.  Microstimulation in the region of the human thalamic principal somatic sensory nucleus evokes sensations like those of mechanical stimulation and movement.

Authors:  Shinji Ohara; Nirit Weiss; Fred A Lenz
Journal:  J Neurophysiol       Date:  2003-10-22       Impact factor: 2.714

10.  Microstimulation of primary afferent neurons in the L7 dorsal root ganglia using multielectrode arrays in anesthetized cats: thresholds and recruitment properties.

Authors:  R A Gaunt; J A Hokanson; D J Weber
Journal:  J Neural Eng       Date:  2009-09-01       Impact factor: 5.379

View more
  35 in total

1.  Self-powered therapeutic release from conducting polymer/graphene oxide films on magnesium.

Authors:  Kasey Catt; Huaxiu Li; Victor Hoang; Roland Beard; X Tracy Cui
Journal:  Nanomedicine       Date:  2017-05-29       Impact factor: 5.307

2.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

3.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

4.  Ultrasoft microwire neural electrodes improve chronic tissue integration.

Authors:  Zhanhong Jeff Du; Christi L Kolarcik; Takashi D Y Kozai; Silvia D Luebben; Shawn A Sapp; Xin Sally Zheng; James A Nabity; X Tracy Cui
Journal:  Acta Biomater       Date:  2017-02-06       Impact factor: 8.947

5.  Elastomeric and soft conducting microwires for implantable neural interfaces.

Authors:  Christi L Kolarcik; Silvia D Luebben; Shawn A Sapp; Jenna Hanner; Noah Snyder; Takashi D Y Kozai; Emily Chang; James A Nabity; Shawn T Nabity; Carl F Lagenaur; X Tracy Cui
Journal:  Soft Matter       Date:  2015-05-20       Impact factor: 3.679

6.  Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo.

Authors:  Takashi D Y Kozai; Andrea S Jaquins-Gerstl; Alberto L Vazquez; Adrian C Michael; X Tracy Cui
Journal:  Biomaterials       Date:  2016-02-10       Impact factor: 12.479

7.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

8.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

9.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

10.  Poly (3, 4-ethylenedioxythiophene)-ionic liquid coating improves neural recording and stimulation functionality of MEAs.

Authors:  Zhanhong Jeff Du; Xiliang Luo; Cassandra Weaver; Xinyan Tracy Cui
Journal:  J Mater Chem C Mater       Date:  2015-04-27       Impact factor: 7.393

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.