Literature DB >> 15965600

Response of primary fibroblasts and osteoblasts to plasma treated polyetheretherketone (PEEK) surfaces.

D Briem1, S Strametz, K Schröder, N M Meenen, W Lehmann, W Linhart, A Ohl, J M Rueger.   

Abstract

Polyetheretherketone (PEEK) is a synthetic polymer with suitable biomechanical and stable chemical properties, which make it attractive for use as an endoprothetic material and for ligamentous replacement. However, chemical surface inertness does not account for a good interfacial biocompatibility, and PEEK requires a surface modification prior to its application in vivo. In the course of this experimental study we analyzed the influence of plasma treatment of PEEK surfaces on the cell proliferation and differentiation of primary fibroblasts and osteoblasts. Further we examined the possibility of inducing microstructured cell growth on a surface with plasma-induced chemical micropatterning. We were able to demonstrate that the surface treatment of PEEK with a low-temperature plasma has significant effects on the proliferation of fibroblasts. Depending on the surface treatment, the proliferation rate can either be stimulated or suppressed. The behavior of the osteoblasts was examined by evaluating differentiation parameters. By detection of alkaline phosphatase, collagen I, and mineralized extracellular matrix as parameters for osteoblastic differentiation, the examined materials showed results comparable to commercially available polymer cell culture materials such as tissue culture polystyrene (TCPS). Further microstructured cell growth was produced successfully on micropatterned PEEK foils, which could be a future tool for bioartificial systems applying the methods of tissue engineering. These results show that chemically inert materials such as PEEK may be modified specifically through the methods of plasma technology in order to improve biocompatibility.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15965600     DOI: 10.1007/s10856-005-2539-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  17 in total

1.  [Surface modifications to improve biocompatibility and mechanical properties of orthopedic implants].

Authors:  R Thull
Journal:  Orthopade       Date:  2003-01       Impact factor: 1.087

2.  Preliminary evaluation of titanium-coated PEEK dental implants.

Authors:  S D Cook; A M Rust-Dawicki
Journal:  J Oral Implantol       Date:  1995       Impact factor: 1.779

3.  Formation of bone by isolated, cultured osteoblasts in millipore diffusion chambers.

Authors:  D J Simmons; G N Kent; R L Jilka; D M Scott; M Fallon; D V Cohn
Journal:  Calcif Tissue Int       Date:  1982-05       Impact factor: 4.333

4.  Polyetheretherketone--cytotoxicity and mutagenicity in vitro.

Authors:  A Katzer; H Marquardt; J Westendorf; J V Wening; G von Foerster
Journal:  Biomaterials       Date:  2002-04       Impact factor: 12.479

5.  Adhesion and growth of CaCo2 cells on surface-modified PEEK substrata.

Authors:  O Noiset; Y J Schneider; J Marchand-Brynaert
Journal:  J Biomater Sci Polym Ed       Date:  2000       Impact factor: 3.517

6.  In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts.

Authors:  C Morrison; R Macnair; C MacDonald; A Wykman; I Goldie; M H Grant
Journal:  Biomaterials       Date:  1995-09       Impact factor: 12.479

7.  Osteoblast responses to orthopedic implant materials in vitro.

Authors:  D A Puleo; L A Holleran; R H Doremus; R Bizios
Journal:  J Biomed Mater Res       Date:  1991-06

8.  In vitro biocompatibility of polyetheretherketone and polysulfone composites.

Authors:  L M Wenz; K Merritt; S A Brown; A Moet; A D Steffee
Journal:  J Biomed Mater Res       Date:  1990-02

9.  Long-term compressive property durability of carbon fibre-reinforced polyetheretherketone composite in physiological saline.

Authors:  G Zhang; R A Latour; J M Kennedy; H Del Schutte; R J Friedman
Journal:  Biomaterials       Date:  1996-04       Impact factor: 12.479

10.  Surfaces modified with covalently-immobilized adhesive peptides affect fibroblast population motility.

Authors:  K C Olbrich; T T Andersen; F A Blumenstock; R Bizios
Journal:  Biomaterials       Date:  1996-04       Impact factor: 12.479

View more
  32 in total

1.  In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy.

Authors:  E Vasilescu; P Drob; D Raducanu; V D Cojocaru; I Cinca; D Iordachescu; R Ion; M Popa; C Vasilescu
Journal:  J Mater Sci Mater Med       Date:  2010-03-25       Impact factor: 3.896

2.  Differentiation of human mesenchymal stem cells on plasma-treated polyetheretherketone.

Authors:  Jasmin Waser-Althaus; Achim Salamon; Marcus Waser; Celestino Padeste; Michael Kreutzer; Uwe Pieles; Bert Müller; Kirsten Peters
Journal:  J Mater Sci Mater Med       Date:  2013-11-08       Impact factor: 3.896

3.  Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone.

Authors:  Rene Olivares-Navarrete; Rolando A Gittens; Jennifer M Schneider; Sharon L Hyzy; David A Haithcock; Peter F Ullrich; Zvi Schwartz; Barbara D Boyan
Journal:  Spine J       Date:  2012-03-15       Impact factor: 4.166

4.  Apatite-forming PEEK with TiO2 surface layer coating.

Authors:  Takashi Kizuki; Tomiharu Matsushita; Tadashi Kokubo
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

5.  Effect of Surface Treatment With Er:YAG and CO2 Lasers on Shear Bond Strength of Polyether Ether Ketone to Composite Resin Veneers.

Authors:  Yousef Jahandideh; Mehran Falahchai; Hossein Pourkhalili
Journal:  J Lasers Med Sci       Date:  2020-03-15

6.  Getting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices.

Authors:  F Brennan Torstrick; David L Safranski; J Kenneth Burkus; James L Chappuis; Christopher S D Lee; Robert E Guldberg; Ken Gall; Kathryn E Smith
Journal:  Tech Orthop       Date:  2017-09-01

7.  Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?

Authors:  F Brennan Torstrick; Nathan T Evans; Hazel Y Stevens; Ken Gall; Robert E Guldberg
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

8.  Bioactive amorphous magnesium phosphate-polyetheretherketone composite filaments for 3D printing.

Authors:  Prabaha Sikder; Jessica A Ferreira; Ehsan Akbari Fakhrabadi; Karla Z Kantorski; Matthew W Liberatore; Marco C Bottino; Sarit B Bhaduri
Journal:  Dent Mater       Date:  2020-05-22       Impact factor: 5.304

9.  Hydroxyapatite coating on PEEK implants: Biomechanical and histological study in a rabbit model.

Authors:  John W Durham; Sergio A Montelongo; Joo L Ong; Teja Guda; Matthew J Allen; Afsaneh Rabiei
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2016-06-15       Impact factor: 7.328

10.  Preparation, characterization and in vitro response of bioactive coatings on polyether ether ketone.

Authors:  John W Durham; Matthew J Allen; Afsaneh Rabiei
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-11-27       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.