Literature DB >> 15956129

Impact of prosthesis-patient size on functional recovery after aortic valve replacement.

Colleen Gorman Koch1, Farah Khandwala, Fawzy G Estafanous, Floyd D Loop, Eugene H Blackstone.   

Abstract

BACKGROUND: Prosthesis-patient size mismatch results when an implanted prosthetic aortic valve is of insufficient size for a patient's body surface area. The relation between prosthesis-patient size and functional capacity and adverse postoperative outcome is inconsistent. Our objectives were to examine the impact of valve replacement, continuous prosthesis-patient size, and other factors on functional recovery after aortic valve replacement (AVR) with the Duke Activity Status Index (DASI). METHODS AND
RESULTS: From June 15, 1995, through May 14, 1998, 1108 patients underwent AVR after completing a DASI survey. Of these, 1014 completed a postoperative DASI survey at an average of 8.3 months postoperatively. Logistic ordinal regression was used to examine the influence of demographic variables, comorbidities, baseline DASI scores, indexed valve orifice area, standardized orifice size, and postoperative morbid events on postoperative DASI. There was overall improvement in postoperative functional recovery reflected by median preoperative and postoperative DASI scores of 29 and 46, P<0.001, respectively. Neither indexed orifice area, P=0.94, nor standardized orifice size, P=0.96, was associated with functional recovery. Female sex, increasing age, elevated serum creatinine, increased central venous pressure, and red blood cell transfusion were factors associated with poor postoperative functional recovery.
CONCLUSIONS: A majority of patients report improvement in functional quality of life early after AVR. Similar functional recovery was demonstrated for patients along the full spectrum of valve sizes indexed to body size, even for values considered to represent severe mismatch for patient size. Factors other than prosthesis-patient size influence functional quality of life early after AVR.

Entities:  

Mesh:

Year:  2005        PMID: 15956129     DOI: 10.1161/CIRCULATIONAHA.104.505248

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  12 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

Review 3.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

4.  Marked discrepancy in pressure gradient between Doppler and catheter examinations on Medtronic Mosaic valve in aortic position.

Authors:  Toshiaki Ito; Atsuo Maekawa; Genyo Fujii; Sadanari Sawaki; Satoshi Hoshino; Yasunari Hayashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-06-12

5.  Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?

Authors:  Sabine Bleiziffer; Walter B Eichinger; Ina Hettich; Ralf Guenzinger; Daniel Ruzicka; Robert Bauernschmitt; Ruediger Lange
Journal:  Heart       Date:  2006-12-12       Impact factor: 5.994

6.  Aortic root widening: "pro et contra".

Authors:  Balaji Srimurugan; Neethu Krishna; Rajesh Jose; Kirun Gopal; Praveen Kerala Varma
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-02-22

7.  Effect of prosthesis-patient mismatch on survival after aortic valve replacement using mechanical prostheses in patients with aortic stenosis.

Authors:  Koji Tsutsumi; Masashi Nagumo; Kuni Nishikawa; Ryuichi Takahashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-12-16

8.  Patient-prosthesis mismatch after aortic valve replacement in the elderly.

Authors:  Masaaki Ryomoto; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Yasuhiko Kobayashi; Shinya Fukui; Noriko Tsujiya; Tetsuya Kajiyama; Yuji Miyamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-07-08

9.  Long-Term Results (up to 20 Years) of 19 mm or Smaller Prostheses in the Aortic Position. Does Size Matter? A Propensity-Matched Survival Analysis.

Authors:  Horea Feier; Andrei Grigorescu; Lucian Falnita; Oana Rachita; Marian Gaspar; Constantin T Luca
Journal:  J Clin Med       Date:  2021-05-11       Impact factor: 4.241

10.  Effect of surgeon on transprosthetic gradients after aortic valve replacement with Freestyle stentless bioprosthesis and its consequences: a follow-up study in 587 patients.

Authors:  Alexander Albert; Ines Florath; Ulrich Rosendahl; Wael Hassanein; Eberhard V Hodenberg; Stefan Bauer; Ina Ennker; Jürgen Ennker
Journal:  J Cardiothorac Surg       Date:  2007-10-05       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.