Literature DB >> 15947995

Fluoroscopic radiation exposure of the kyphoplasty patient.

Bronek M Boszczyk1, Michael Bierschneider, Stephanie Panzer, Werner Panzer, Roger Harstall, Katharina Schmid, Hans Jaksche.   

Abstract

Kyphoplasty (KP) is a minimally invasive technique for the percutaneous stabilisation of vertebral fractures. As such, this technique is highly dependent upon intraoperative fluoroscopic visualisation. In order to assess the range of radiation doses that patients are typically subjected to, 60 consecutive procedures using simultaneous bilateral fluoroscopy were analysed with respect to exposure time (ET). In a subset of 16 of these patients, a theoretical entrance skin dose (ESD) and effective dose was additionally calculated from intraoperatively measured dose area product. Average fluoroscopy time for single level cases reached 2.2 min (range 0.6-4.3) in the lateral plane and 1.6 min (range 0.5-3.0) in the anterior-posterior plane. For multiple level cases the corresponding ET per level was 1.7 min (range 0.6-2.9) per level in the lateral and 1.1 min (range 0.5-2.0) in the anterior-posterior plane. ESD was estimated as an average 0.32 Gy (range 0.05-0.86) in the anterior-posterior and 0.68 Gy (range 0.10-1.43) in the lateral plane. Effective dose (cumulative from both planes) averaged 4.28 mSv (range 0.47-10.14). Safety margins for the development of early transient erythema are respected within the presented fluoroscopy times. Longer ET in the lateral plane may however breach the 2 Gy threshold. Use of large c-arms and judiciously operating the exposure is recommended. With regard to effective dose, a single fluoroscopy guided KP performed for osteoporotic or traumatic vertebral fractures is a safe procedure.

Entities:  

Mesh:

Year:  2005        PMID: 15947995      PMCID: PMC3489303          DOI: 10.1007/s00586-005-0952-0

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  14 in total

1.  [CT radiation exposure risk in Germany].

Authors:  M Galanski; H D Nagel; G Stamm
Journal:  Rofo       Date:  2001-10

2.  Radiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.

Authors:  David F Kallmes; Erwin O; Soma Sinha Roy; Richard G Piccolo; William F Marx; Jae K Lee; Mary E Jensen
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

3.  Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose.

Authors:  Randell Kruger; Thomas Faciszewski
Journal:  Spine (Phila Pa 1976)       Date:  2003-07-15       Impact factor: 3.468

4.  Occupational exposure from common fluoroscopic projections used in orthopaedic surgery.

Authors:  Nicholas Theocharopoulos; Kostas Perisinakis; John Damilakis; George Papadokostakis; Alexander Hadjipavlou; Nicholas Gourtsoyiannis
Journal:  J Bone Joint Surg Am       Date:  2003-09       Impact factor: 5.284

5.  Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty: a prospective study.

Authors:  Roger Harstall; Paul F Heini; Roberto L Mini; Rene Orler
Journal:  Spine (Phila Pa 1976)       Date:  2005-08-15       Impact factor: 3.468

6.  Percutaneous biopsies of the thoracic spine under CT guidance: transcostovertebral approach.

Authors:  P Brugieres; A Gaston; F Heran; M C Voisin; C Marsault
Journal:  J Comput Assist Tomogr       Date:  1990 May-Jun       Impact factor: 1.826

7.  New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures.

Authors:  S R Garfin; H A Yuan; M A Reiley
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

8.  Backscatter factors for diagnostic radiology (1-4 mm Al HVL).

Authors:  R M Harrison
Journal:  Phys Med Biol       Date:  1982-12       Impact factor: 3.609

9.  Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty.

Authors:  Kostas Perisinakis; John Damilakis; Nicholas Theocharopoulos; George Papadokostakis; Alexandros Hadjipavlou; Nicholas Gourtsoyiannis
Journal:  Radiology       Date:  2004-07-23       Impact factor: 11.105

10.  [Conventional and semi-open kyphoplasty].

Authors:  B M Boszczyk; M Bierschneider; S Hauck; J Vastmans; M Potulski; R Beisse; B Robert; H Jaksche
Journal:  Orthopade       Date:  2004-01       Impact factor: 1.087

View more
  18 in total

1.  Safety of fluoroscopy guided percutaneous access to the thoracic spine.

Authors:  Jonathan A Clamp; Edward J Bayley; Firooz V Ebrahimi; Nasir A Quraishi; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2012-02-23       Impact factor: 3.134

2.  Outcome of long-axis percutaneous sacroplasty for the treatment of sacral insufficiency fractures with a radiofrequency-induced, high-viscosity bone cement.

Authors:  Katrin Eichler; Stephan Zangos; Martin G Mack; Ingo Marzi; Thomas J Vogl
Journal:  Skeletal Radiol       Date:  2014-01-23       Impact factor: 2.199

3.  Preclinical usability study of multiple augmented reality concepts for K-wire placement.

Authors:  Marius Fischer; Bernhard Fuerst; Sing Chun Lee; Javad Fotouhi; Severine Habert; Simon Weidert; Ekkehard Euler; Greg Osgood; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-19       Impact factor: 2.924

4.  [Balloonsacroplasty: C-arm or CT controlled application? : Experience with 46 patients].

Authors:  A Prokop; R Andresen; M Chmielnicki
Journal:  Unfallchirurg       Date:  2016-11       Impact factor: 1.000

5.  On-the-fly augmented reality for orthopedic surgery using a multimodal fiducial.

Authors:  Sebastian Andress; Alex Johnson; Mathias Unberath; Alexander Felix Winkler; Kevin Yu; Javad Fotouhi; Simon Weidert; Greg Osgood; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-26

6.  Interactive Flying Frustums (IFFs): spatially aware surgical data visualization.

Authors:  Javad Fotouhi; Mathias Unberath; Tianyu Song; Wenhao Gu; Alex Johnson; Greg Osgood; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-03-12       Impact factor: 2.924

7.  [Balloon kyphoplasty for recent vertebral fractures in the elderly].

Authors:  M D Schofer; C H Illian; J B Illian; H R Kortmann
Journal:  Orthopade       Date:  2008-05       Impact factor: 1.087

8.  Sacroplasty in a cadaveric trial: comparison of CT and fluoroscopic guidance with and without balloon assistance.

Authors:  L Grossterlinden; P G C Begemann; W Lehmann; J Nuechtern; U Schumacher; H D Nagel; W Linhart; G Adam; J M Rueger; D Briem
Journal:  Eur Spine J       Date:  2009-04-22       Impact factor: 3.134

9.  The surgeon's real dose exposure during balloon kyphoplasty procedure and evaluation of the cement delivery system: a prospective study.

Authors:  Frédéric Schils; Werner Schoojans; Lara Struelens
Journal:  Eur Spine J       Date:  2013-02-09       Impact factor: 3.134

Review 10.  Clinical outcomes of sacroplasty in sacral insufficiency fractures: a review of the literature.

Authors:  Edward Bayley; Shreya Srinivas; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-06-06       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.