Literature DB >> 14747906

[Conventional and semi-open kyphoplasty].

B M Boszczyk1, M Bierschneider, S Hauck, J Vastmans, M Potulski, R Beisse, B Robert, H Jaksche.   

Abstract

Kyphoplasty is a young method which was developed for the minimally invasive augmentation of osteoporotic vertebral fractures. In contrast to vertebroplasty, the kyphoplasty technique allows an age-dependent fracture reduction through the inflation of a special balloon in the fractured cancellous bone of the vertebral body. The cancellous bone of the fracture zone is compressed by the balloon, so that a cavity remains in the vertebral body after removing the balloon, which is filled with highly viscous augmentation material. The reduced risk of serious complications, for example epidural leakage of augmentation material, justifies progressively expanding the indications for this technique to traumatic fractures with involvement of the posterior vertebral wall and neoplastic vertebral collapse due to osteolytic metastasis. Besides the indications for the conventional percutaneous approaches, the microsurgical interlaminary approach allows the use of kyphoplasty in more complex fractures involving compression of the neural structures. Kyphoplasty induces swift pain relief and allows rapid mobilisation of patients due to the immediate stabilisation of the affected vertebral bodies. Apart from the operative intervention, the medical treatment of the primary disease and the rehabilitation of the individual patient should be optimised through an interdisciplinary approach.

Entities:  

Mesh:

Year:  2004        PMID: 14747906     DOI: 10.1007/s00132-003-0575-2

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  27 in total

1.  Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate : a case report.

Authors:  K D Harrington
Journal:  J Bone Joint Surg Am       Date:  2001-07       Impact factor: 5.284

2.  Asymptomatic diffuse pulmonary embolism caused by acrylic cement: an unusual complication of percutaneous vertebroplasty.

Authors:  J Bernhard; P F Heini; P M Villiger
Journal:  Ann Rheum Dis       Date:  2003-01       Impact factor: 19.103

3.  An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture.

Authors:  S M Belkoff; J M Mathis; D C Fenton; R M Scribner; M E Reiley; K Talmadge
Journal:  Spine (Phila Pa 1976)       Date:  2001-01-15       Impact factor: 3.468

4.  Effect of augmentation on the mechanics of vertebral wedge fractures.

Authors:  D R Wilson; E R Myers; J M Mathis; R M Scribner; J A Conta; M A Reiley; K D Talmadge; W C Hayes
Journal:  Spine (Phila Pa 1976)       Date:  2000-01-15       Impact factor: 3.468

5.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

6.  Predicting vertebral fracture incidence from prevalent fractures and bone density among non-black, osteoporotic women.

Authors:  P D Ross; H K Genant; J W Davis; P D Miller; R D Wasnich
Journal:  Osteoporos Int       Date:  1993-05       Impact factor: 4.507

7.  Management of pulmonary embolism during acrylic vertebroplasty.

Authors:  Piergiorgio Tozzi; Yasmine Abdelmoumene; Antonio F Corno; Philip A Gersbach; Henri-Marcel Hoogewoud; Ludwig K von Segesser
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

8.  Percutaneous vertebroplasty and kyphoplasty for painful vertebral body fractures in cancer patients.

Authors:  Daryl R Fourney; Donald F Schomer; Remi Nader; Jennifer Chlan-Fourney; Dima Suki; Kamran Ahrar; Laurence D Rhines; Ziya L Gokaslan
Journal:  J Neurosurg       Date:  2003-01       Impact factor: 5.115

9.  Pulmonary embolism of polymethylmethacrylate after percutaneous vertebroplasty: a report of three cases.

Authors:  Jee Soo Jang; Sang Ho Lee; Sang Ki Jung
Journal:  Spine (Phila Pa 1976)       Date:  2002-10-01       Impact factor: 3.468

10.  A comprehensive classification of thoracic and lumbar injuries.

Authors:  F Magerl; M Aebi; S D Gertzbein; J Harms; S Nazarian
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

View more
  3 in total

1.  Fluoroscopic radiation exposure of the kyphoplasty patient.

Authors:  Bronek M Boszczyk; Michael Bierschneider; Stephanie Panzer; Werner Panzer; Roger Harstall; Katharina Schmid; Hans Jaksche
Journal:  Eur Spine J       Date:  2005-06-10       Impact factor: 3.134

2.  [Balloon kyphoplasty for recent vertebral fractures in the elderly].

Authors:  M D Schofer; C H Illian; J B Illian; H R Kortmann
Journal:  Orthopade       Date:  2008-05       Impact factor: 1.087

Review 3.  [Treatment options for problematic thoracic and lumbar osteoporotic fractures].

Authors:  C E Heyde; Z Fekete; Y Robinson; S K Tschöke; R Kayser
Journal:  Orthopade       Date:  2008-04       Impact factor: 1.087

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.