A Ayav1, L Bresler, J Hubert, L Brunaud, P Boissel. 1. Department of Digestive Surgery, University Hospital of Nancy-Brabois, 54511 Vandoeuvre les Nancy, France. a.ayav@chu-nancy.fr
Abstract
BACKGROUND: This study describes technical aspect and short-term results of pelvic organ prolapse surgery using the da Vinci robotic system. METHODS: During a 1-year period, 18 consecutive patients with pelvic organ prolapse were operated on using the da-Vinci system. Clinical data were prospectively collected and analyzed. RESULTS: All but one procedure was successfully completed robotically (95%). Performed procedures were colpohysteropexy (n = 12), mesh rectopexy (n = 2), or sutured rectopexy combined with sigmoid resection (n = 4). Average setup time was 21 min and significantly decreased with experience. Mean operative time was 172 min (range, 45-280). There were no mortality and no specific morbidity due to the robotic approach. Mean hospital stay was 7 days. At 6 months, all patients were free of pelvic organ prolapse and stated that they were satisfied with anatomical and functional results. CONCLUSION: Our experience indicates that using the da-Vinci robotic system is feasible, safe, and effective for the treatment of pelvic organ prolapse.
BACKGROUND: This study describes technical aspect and short-term results of pelvic organ prolapse surgery using the da Vinci robotic system. METHODS: During a 1-year period, 18 consecutive patients with pelvic organ prolapse were operated on using the da-Vinci system. Clinical data were prospectively collected and analyzed. RESULTS: All but one procedure was successfully completed robotically (95%). Performed procedures were colpohysteropexy (n = 12), mesh rectopexy (n = 2), or sutured rectopexy combined with sigmoid resection (n = 4). Average setup time was 21 min and significantly decreased with experience. Mean operative time was 172 min (range, 45-280). There were no mortality and no specific morbidity due to the robotic approach. Mean hospital stay was 7 days. At 6 months, all patients were free of pelvic organ prolapse and stated that they were satisfied with anatomical and functional results. CONCLUSION: Our experience indicates that using the da-Vinci robotic system is feasible, safe, and effective for the treatment of pelvic organ prolapse.
Authors: W S Melvin; B J Needleman; K R Krause; C Schneider; R K Wolf; R E Michler; E C Ellison Journal: Surg Endosc Date: 2002-09-23 Impact factor: 4.584
Authors: Franziska Huettner; Paul E Pacheco; Jamie L Doubet; Michael J Ryan; Danuta I Dynda; David L Crawford Journal: J Gastrointest Surg Date: 2011-05-21 Impact factor: 3.452
Authors: Amir Szold; Roberto Bergamaschi; Ivo Broeders; Jenny Dankelman; Antonello Forgione; Thomas Langø; Andreas Melzer; Yoav Mintz; Salvador Morales-Conde; Michael Rhodes; Richard Satava; Chung-Ngai Tang; Ramon Vilallonga Journal: Surg Endosc Date: 2014-11-08 Impact factor: 4.584
Authors: A Germain; F Thibault; M Galifet; M-L Scherrer; A Ayav; J Hubert; L Brunaud; L Bresler Journal: Surg Endosc Date: 2012-07-18 Impact factor: 4.584
Authors: Zhobin Moghadamyeghaneh; Mark H Hanna; Joseph C Carmichael; Alessio Pigazzi; Michael J Stamos; Steven Mills Journal: Surg Endosc Date: 2015-10-20 Impact factor: 4.584
Authors: Rao K Mehmood; Jody Parker; L Bhuvimanian; Eyas Qasem; Ahmed A Mohammed; Muhammad Zeeshan; Kirsten Grugel; Paul Carter; Shakil Ahmed Journal: Int J Colorectal Dis Date: 2014-06-26 Impact factor: 2.571