Long-term clinical results of the medial Oxford unicompartmental knee arthroplasty.

A J Price1, J C Waite, U Svard.   

Abstract

UNLABELLED: The medial Oxford unicompartmental knee arthroplasty uses a fully congruent mobile bearing, varying in thickness from 3.5-11.5 mm. Impressive clinical and survival results have been achieved by the designing surgeon, but can they be reproduced by an independent center and does the use of bearings less than 6 mm thick reduce the implant's survival? Between November 1983 and May 2000, 439 medial Oxford prostheses were implanted by three surgeons in Skovde, Sweden. One hundred fourteen knees (89 patients) were reviewed clinically at a minimum of 10 years postoperatively, using the Hospital for Special Surgery knee score. Ninety-one percent of the knees had good or excellent results, with no poor results, and 82% were reported as pain free. The 15-year survival rate for the entire cohort was 93%, and for the 432 knees (344 patients) that met the current indications for using the device, the survival rate was 94%. The 10-year survival rate for bearings less than 6 mm thick was 95%, compared with 94% with bearings greater than 6 mm. The results show that an independent center can achieve excellent long-term clinical and survival results in patients implanted with the Oxford prosthesis. Survival of the implant was not reduced by the use of thin polyethylene bearings. LEVEL OF EVIDENCE: Therapeutic study, Level IV (case series--no, or historical, control group). See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2005        PMID: 15930935     DOI: 10.1097/00003086-200506000-00024

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  62 in total

1.  The impact of a high tibial valgus osteotomy and unicondylar medial arthroplasty on the treatment for knee osteoarthritis: a meta-analysis.

Authors:  Gunter Spahn; Gunther O Hofmann; Lars Victor von Engelhardt; Mengxia Li; Henning Neubauer; Hans Michael Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-11       Impact factor: 4.342

Review 2.  Management of osteoarthritis of the knee.

Authors:  Andrew Price; Robin Allum
Journal:  Ann R Coll Surg Engl       Date:  2010-09       Impact factor: 1.891

3.  Overstuffed medial compartment after mobile-bearing unicompartmental knee arthroplasty.

Authors:  B Kerens; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-11       Impact factor: 4.342

4.  Survival analysis and functional outcome of the Oxford unicompartmental knee replacement up to 11 years follow up at a District General Hospital.

Authors:  M Edmondson; A Atrey; D East; N Ellens; K Miles; R Goddard; H Apthorp; A Butler-Manuel
Journal:  J Orthop       Date:  2015-05-18

5.  Extended sagittal saw cut significantly reduces fracture load in cementless unicompartmental knee arthroplasty compared to cemented tibia plateaus: an experimental cadaver study.

Authors:  J B Seeger; D Haas; S Jäger; E Röhner; S Tohtz; M Clarius
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

6.  Functional improvement after unicompartmental knee replacement: a follow-up study with a performance based knee test.

Authors:  Lucas L A Kleijn; Wouter L W van Hemert; Will G H Meijers; Arnold D M Kester; Lukas Lisowski; Bernd Grimm; Ide C Heyligers
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-06-23       Impact factor: 4.342

7.  MR imaging of the knee in patients with medial unicompartmental arthroplasty: comparison among sequences at 1.5 T.

Authors:  A Aliprandi; F Perona; M Bandirali; P Randelli; P Cabitza; F Sardanelli
Journal:  Radiol Med       Date:  2009-02-04       Impact factor: 3.469

8.  Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage.

Authors:  Michael Clarius; Christian Hauck; Joern B Seeger; Andrew James; David W Murray; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

9.  Proximal tibial bone density is preserved after unicompartmental knee arthroplasty.

Authors:  Bradley I Richmond; Simon V Hadlow; Tim G Lynskey; Cameron G Walker; Jacob T Munro
Journal:  Clin Orthop Relat Res       Date:  2013-01-17       Impact factor: 4.176

10.  Medial femoral condyle fracture as an intraoperative complication of Oxford unicompartmental knee replacement.

Authors:  Bart Ten Brinke; Laurens J de Haan; Koen L M Koenraadt; Rutger C I van Geenen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-12-06       Impact factor: 4.342

View more