Literature DB >> 15862774

An investigation of enhanced secondary ion emission under Au(n)+ (n = 1-7) bombardment.

G Nagy1, L D Gelb, A V Walker.   

Abstract

We investigate the mechanism of the nonlinear secondary ion yield enhancement using Au(n)+ (n = 1, 2, 3, 5, 7) primary ions bombarding thin films of Irganox 1010, DL-phenylalanine and polystyrene on Si, Al, and Ag substrates. The largest differences in secondary ion yields are found using Au+, Au2+, and Au3+ primary ion beams. A smaller increase in secondary ion yield is observed using Au5+ and Au7+ primary ions. The yield enhancement is found to be larger on Si than on Al, while the ion yield is smaller using an Au+ beam on Si than on Al. Using Au(n)+ ion structures obtained from Density Functional Theory, we demonstrate that the secondary yield enhancement is not simply due to an increase in energy per area deposited into the surface (energy deposition density). Instead, based on simple mechanical arguments and molecular dynamics results from Medvedeva et al, we suggest a mechanism for nonlinear secondary ion yield enhancement wherein the action of multiple concerted Au impacts leads to efficient energy transfer to substrate atoms in the near surface region and an increase in the number of secondary ions ejected from the surface. Such concerted impacts involve one, two, or three Au atoms, which explains well the large nonlinear yield enhancements observed going from Au+ to Au2+ to Au3+ primary ions. This model is also able to explain the observed substrate effect. For an Au+ ion passing through the more open Si surface, it contacts fewer substrate atoms than in the more dense Al surface. Less energy is deposited in the Si surface region by the Au+ primary ion and the secondary ion yield will be lower for adsorbates on Si than on Al. In the case of Au(n)+ the greater density of Al leads to earlier break-up of the primary ion and a consequent reduction in energy transfer to the near-surface region when compared with Si. This results in higher secondary ion yields and yield enhancements on silicon than aluminum substrates.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15862774     DOI: 10.1016/j.jasms.2005.01.024

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  6 in total

Review 1.  Molecule liftoff from surfaces.

Authors:  B J Garrison; A Delcorte; K D Krantzman
Journal:  Acc Chem Res       Date:  2000-02       Impact factor: 22.384

2.  Imaging with mass spectrometry.

Authors:  M L Pacholski; N Winograd
Journal:  Chem Rev       Date:  1999-10-13       Impact factor: 60.622

3.  A C60 primary ion beam system for time of flight secondary ion mass spectrometry: its development and secondary ion yield characteristics.

Authors:  Daniel Weibel; Steve Wong; Nicholas Lockyer; Paul Blenkinsopp; Rowland Hill; John C Vickerman
Journal:  Anal Chem       Date:  2003-04-01       Impact factor: 6.986

4.  Atoms, molecules, solids, and surfaces: Applications of the generalized gradient approximation for exchange and correlation.

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1992-09-15

5.  Tissue molecular ion imaging by gold cluster ion bombardment.

Authors:  David Touboul; Fréderic Halgand; Alain Brunelle; Reinhard Kersting; Elke Tallarek; Birgit Hagenhoff; Olivier Laprévote
Journal:  Anal Chem       Date:  2004-03-15       Impact factor: 6.986

6.  Preliminary evaluation of an SF5+ polyatomic primary ion beam for analysis of organic thin films by secondary ion mass spectrometry.

Authors:  G Gillen; S Roberson
Journal:  Rapid Commun Mass Spectrom       Date:  1998       Impact factor: 2.419

  6 in total
  5 in total

1.  Equilibrium geometries, stabilities, and electronic properties of the cationic Au n Be + (n = 1-8) clusters: comparison with pure gold clusters.

Authors:  Peng Shao; Xiao-Yu Kuang; Ya-Ru Zhao; Yan-Fang Li; Su-Juan Wang
Journal:  J Mol Model       Date:  2012-02-14       Impact factor: 1.810

2.  Improvement of biological time-of-flight-secondary ion mass spectrometry imaging with a bismuth cluster ion source.

Authors:  David Touboul; Felix Kollmer; Ewald Niehuis; Alain Brunelle; Olivier Laprévote
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

3.  An investigation of secondary ion yield enhancement using Bin2+ (n=1,3,5) primary ions.

Authors:  Gabriella Nagy; Peng Lu; Amy V Walker
Journal:  J Am Soc Mass Spectrom       Date:  2008-01       Impact factor: 3.109

4.  Use of TOF-SIMS to study adsorption and loading behavior of methylene blue and papain in a nano-porous silicon layer.

Authors:  Ivan M Kempson; Timothy J Barnes; Clive A Prestidge
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-17       Impact factor: 3.109

Review 5.  Autoradiography, MALDI-MS, and SIMS-MS imaging in pharmaceutical discovery and development.

Authors:  Eric G Solon; Alain Schweitzer; Markus Stoeckli; Brendan Prideaux
Journal:  AAPS J       Date:  2009-11-17       Impact factor: 4.009

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.