Array coils can potentially offer increased signal-to-noise ratio (SNR) over standard coils adjacent to the array elements, while preserving the SNR at the center of the volume. The SNR advantage should theoretically increase with the number of array elements. Parallel acquisition techniques (PAT), on the other hand, can benefit acquisition times or spatial resolution at a cost to SNR as well as image quality. This study examines the question of whether SNR and image quality are still acceptable with two different array coils (four and eight channels) in conjunction with PAT when compared to standard imaging with a volume coil. All imaging was on a 1.5 T MR scanner. T2-weighted, FLAIR, diffusion-weighted, and time of flight (TOF) angiography images were performed with and without PAT in a phantom and in ten healthy volunteers. The phantom measurements demonstrated superior SNR for the eight-channel coil versus the four-channel and standard head coils. Using the eight-channel head coil for in vivo imaging, image quality with PAT (acceleration factor=2) was scored similar to images without PAT using the volume coil. The four-channel head coil suffered from inhomogeneity, lower SNR and poorer image quality when using PAT compared to standard imaging with the volume head coil. Both the in vivo and the phantom results indicate that the eight-channel head coil should be used for the highest quality brain images; this coil can be combined with PAT sequences for shorter acquisition time without a significant decrease in image quality relative to a volume coil without PAT.

Entities:  

Mesh:

Year:  2005        PMID: 15856247     DOI: 10.1007/s00330-005-2730-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  14 in total

Review 1.  SMASH imaging.

Authors:  D K Sodickson; M A Griswold; P M Jakob
Journal:  Magn Reson Imaging Clin N Am       Date:  1999-05       Impact factor: 2.266

2.  A three-coil comparison for MR angiography.

Authors:  J R Hadley; B E Chapman; J A Roberts; D C Chapman; K C Goodrich; H R Buswell; A L Alexander; J S Tsuruda; D L Parker
Journal:  J Magn Reson Imaging       Date:  2000-04       Impact factor: 4.813

3.  A comparison of two methods for measuring the signal to noise ratio on MR images.

Authors:  M J Firbank; A Coulthard; R M Harrison; E D Williams
Journal:  Phys Med Biol       Date:  1999-12       Impact factor: 3.609

4.  Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Authors:  Daniel K Sodickson; Charles A McKenzie; Michael A Ohliger; Ernest N Yeh; Mark D Price
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Olaf Dietrich; Johannes Rieber; Matthias Nittka; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2003-05-29       Impact factor: 5.315

7.  New partially parallel acquisition technique in cerebral imaging: preliminary findings.

Authors:  Jaroslav Tintera; Joachim Gawehn; Thomas Bauermann; Goran Vucurevic; Peter Stoeter
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

8.  Field-of-view limitations in parallel imaging.

Authors:  Mark A Griswold; Stephan Kannengiesser; Robin M Heidemann; Jianmin Wang; Peter M Jakob
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

9.  3D time-of-flight MR angiography of the intracranial vessels: optimization of the technique with water excitation, parallel acquisition, eight-channel phased-array head coil and low-dose contrast administration.

Authors:  O Ozsarlak; J W Van Goethem; P M Parizel
Journal:  Eur Radiol       Date:  2004-07-31       Impact factor: 5.315

10.  Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Akira Fujikawa; Junichi Hachiya
Journal:  Eur Radiol       Date:  2004-03-20       Impact factor: 5.315

View more
  4 in total

1.  Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5 T with 3.0 T.

Authors:  Mike P Wattjes; Götz G Lutterbey; Michael Harzheim; Jürgen Gieseke; Frank Träber; Luisa Klotz; Thomas Klockgether; Hans H Schild
Journal:  Eur Radiol       Date:  2006-04-29       Impact factor: 5.315

2.  Novel practical SNR determination method for MRI using double echo with longest second echo time (DELSET).

Authors:  Naoki Ohno; Tosiaki Miyati; Yoshiaki Niwa; Hirohito Kan; Shota Ishida; Harumasa Kasai; Yuta Shibamoto; Toshifumi Gabata
Journal:  Br J Radiol       Date:  2018-04-04       Impact factor: 3.039

3.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

4.  Optimization of b value in diffusion-weighted MRI for the differential diagnosis of benign and malignant vertebral fractures.

Authors:  Guangyu Tang; Yong Liu; Wei Li; Jiping Yao; Baoping Li; Peng Li
Journal:  Skeletal Radiol       Date:  2007-09-01       Impact factor: 2.199

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.