Literature DB >> 15855362

Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up.

E Dunstan1, A P Sanghrajka, S Tilley, P Unwin, G Blunn, S R Cannon, T W R Briggs.   

Abstract

Metal-on-metal hip bearings are being implanted into younger patients. The consequence of elevated levels of potentially carcinogenic metal ions is therefore a cause for concern. We have determined the levels of cobalt (Co), chromium (Cr), titanium (Ti) and vanadium (Va) in the urine and whole blood of patients who had had metal-on-metal and metal-on-polyethylene articulations in situ for more than 30 years. We compared these with each other and with the levels for a control group of subjects. We found significantly elevated levels of whole blood Ti, Va and urinary Cr in all arthroplasty groups. The whole blood and urine levels of Co were grossly elevated, by a factor of 50 and 300 times respectively in patients with loose metal-on-metal articulations when compared with the control group. Stable metal-on-metal articulations showed much lower levels. Elevated levels of whole blood or urinary Co may be useful in identifying metal-on-metal articulations which are loose.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15855362     DOI: 10.1302/0301-620X.87B5.15384

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  16 in total

1.  The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Harry McKellop; Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 2.  Hip resurfacing: a technology reborn.

Authors:  Steven Cutts; Paul B Carter
Journal:  Postgrad Med J       Date:  2006-12       Impact factor: 2.401

3.  Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

Authors:  Joerg Friesenbichler; Werner Maurer-Ertl; Patrick Sadoghi; Thomas Lovse; Reinhard Windhager; Andreas Leithner
Journal:  Int Orthop       Date:  2011-07-14       Impact factor: 3.075

4.  Metal ions activate vascular endothelial cells and increase lymphocyte chemotaxis and binding.

Authors:  James T Ninomiya; Scott A Kuzma; Timothy J Schnettler; John G Krolikowski; Janine A Struve; Dorothee Weihrauch
Journal:  J Orthop Res       Date:  2013-04-29       Impact factor: 3.494

Review 5.  What are the advantages and disadvantages of imaging modalities to diagnose wear-related corrosion problems?

Authors:  Denis Nam; Robert L Barrack; Hollis G Potter
Journal:  Clin Orthop Relat Res       Date:  2014-03-25       Impact factor: 4.176

6.  Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Authors:  Alister J Hart; John A Skinner; Johann Henckel; Barry Sampson; Fabiana Gordon
Journal:  Clin Orthop Relat Res       Date:  2011-06-09       Impact factor: 4.176

7.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

8.  Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-02-01

9.  [In vitro analysis of the impact of metal ions on human lymphocyte cultures].

Authors:  S Hagmann; J Kirsch; J P Kretzer; B Moradi
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

Review 10.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11
View more