Literature DB >> 15843738

Stability of miniature electromagnetic tracking systems.

Kurt Schicho1, Michael Figl, Markus Donat, Wolfgang Birkfellner, Rudolf Seemann, Arne Wagner, Helmar Bergmann, Rolf Ewers.   

Abstract

This study aims at a comparative evaluation of two recently introduced electromagnetic tracking systems under reproducible simulated operating-room (OR) conditions: the recently launched Medtronic StealthStation, Treon-EM and the NDI Aurora. We investigate if and to what extent these systems provide improved performance and stability in the presence of surgical instruments as possible sources of distortions compared with earlier reports on electromagnetic tracking technology. To investigate possible distortions under pseudo-realistic OR conditions, a large Langenbeck hook, a dental drill with its handle and an ultrasonic (US) scanhead are fixed on a special measurement rack at variable distances from the navigation sensor. The position measurements made by the Treon-EM were least affected by the presence of the instruments. The lengths of the mean deviation vectors were 0.21 mm for the Langenbeck hook, 0.23 mm for the drill with handle and 0.56 mm for the US scanhead. The Aurora was influenced by the three sources of distortion to a higher degree. A mean deviation vector of 1.44 mm length was observed in the vicinity of the Langenbeck hook, 0.53 mm length with the drill and 2.37 mm due to the US scanhead. The maximum of the root mean squared error (RMSE) for all coordinates in the presence of the Langenbeck hook was 0.3 mm for the Treon and 2.1 mm for the Aurora; the drill caused a maximum RMSE of 0.2 mm with the Treon and 1.2 mm with the Aurora. In the presence of the US scanhead, the maximum RMSE was 1.4 mm for the Treon and 5.1 mm for the Aurora. The new generation of electromagnetic tracking systems has significantly improved compared to common systems that were available in the middle of the 1990s and has reached a high level of technical development. We conclude that, in general, both systems are suitable for routine clinical application.

Entities:  

Mesh:

Year:  2005        PMID: 15843738     DOI: 10.1088/0031-9155/50/9/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Potential use of computer navigation in the treatment of primary benign and malignant tumors in children.

Authors:  Kevan Saidi
Journal:  Curr Rev Musculoskelet Med       Date:  2012-06

2.  Augmented reality haptic (ARH): an approach of electromagnetic tracking in minimally invasive surgery.

Authors:  J B Pagador; L F Sánchez; J A Sánchez; P Bustos; J Moreno; F M Sánchez-Margallo
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-02       Impact factor: 2.924

3.  Calibration and Evaluation of a Magnetically Tracked ICE Probe for Guidance of Left Atrial Ablation Therapy.

Authors:  Cristian A Linte; Maryam E Rettmann; Ben Dilger; Mia S Gunawan; Shivaram Poigai Arunachalam; David R Holmes; Douglas L Packer; Richard A Robb
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-04

4.  Classical and real-time neuronavigation in pediatric neurosurgery.

Authors:  Jonathan Roth; Liana Beni-Adani; Naresh Biyani; Shlomi Constantini
Journal:  Childs Nerv Syst       Date:  2006-06-08       Impact factor: 1.475

5.  Development of a navigation system for minimally invasive esophagectomy.

Authors:  H G Kenngott; J Neuhaus; B P Müller-Stich; I Wolf; M Vetter; H-P Meinzer; J Köninger; M W Büchler; C N Gutt
Journal:  Surg Endosc       Date:  2007-12-20       Impact factor: 4.584

Review 6.  Navigated laparoscopic ultrasound in abdominal soft tissue surgery: technological overview and perspectives.

Authors:  Thomas Langø; Sinara Vijayan; Anna Rethy; Cecilie Våpenstad; Ole Vegard Solberg; Ronald Mårvik; Gjermund Johnsen; Toril N Hernes
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-03       Impact factor: 2.924

7.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

8.  Osteomark: a surgical navigation system for oral and maxillofacial surgery.

Authors:  C Bouchard; J C Magill; V Nikonovskiy; M Byl; B A Murphy; L B Kaban; M J Troulis
Journal:  Int J Oral Maxillofac Surg       Date:  2011-11-21       Impact factor: 2.789

9.  Minimizing electromagnetic interference from surgical instruments on electromagnetic surgical navigation.

Authors:  Faustin Stevens; Michael A Conditt; Nikhil Kulkarni; Sabir K Ismaily; Philip C Noble; David R Lionberger
Journal:  Clin Orthop Relat Res       Date:  2010-05-29       Impact factor: 4.176

10.  Robot-assisted mandibular angle osteotomy using electromagnetic navigation.

Authors:  Mengzhe Sun; Li Lin; Xiaojun Chen; Cheng Xu; Mar Aung Zin; Wenqing Han; Gang Chai
Journal:  Ann Transl Med       Date:  2021-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.