Calibration and Evaluation of a Magnetically Tracked ICE Probe for Guidance of Left Atrial Ablation Therapy.

Cristian A Linte1, Maryam E Rettmann1, Ben Dilger2, Mia S Gunawan3, Shivaram Poigai Arunachalam4, David R Holmes1, Douglas L Packer5, Richard A Robb1.   

Abstract

The novel prototype system for advanced visualization for image-guided left atrial ablation therapy developed in our laboratory permits ready integration of multiple imaging modalities, surgical instrument tracking, interventional devices and electro-physiologic data. This technology allows subject-specific procedure planning and guidance using 3D dynamic, patient-specific models of the patient's heart, augmented with real-time intracardiac echocardiography (ICE). In order for the 2D ICE images to provide intuitive visualization for accurate catheter to surgical target navigation, the transducer must be tracked, so that the acquired images can be appropriately presented with respect to the patient-specific anatomy. Here we present the implementation of a previously developed ultrasound calibration technique for a magnetically tracked ICE transducer, along with a series of evaluation methods to ensure accurate imaging and faithful representation of the imaged structures. Using an engineering-designed phantom, target localization accuracy is assessed by comparing known target locations with their transformed locations inferred from the tracked US images. In addition, the 3D volume reconstruction accuracy is also estimated by comparing a truth volume to that reconstructed from sequential 2D US images. Clinically emulating validation studies are conducted using a patient-specific left atrial phantom. Target localization error of clinically-relevant surgical targets represented by nylon fiducials implanted within the endocardial wall of the phantom was assessed. Our studies have demonstrated 2.4 ± 0.8 mm target localization error in the engineering-designed evaluation phantoms, 94.8 ± 4.6 % volume reconstruction accuracy, and 3.1 ± 1.2 mm target localization error in the left atrial-mimicking phantom. These results are consistent with those disseminated in the literature and also with the accuracy constraints imposed by the employed technology and the clinical application.

Entities:  

Keywords:  Calibration; Image-Guided Cardiac Procedures; Intra-operative Imaging; Localization and Tracking Technologies; Ultrasound Guidance

Year:  2012        PMID: 26401065      PMCID: PMC4576348          DOI: 10.1117/12.912869

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

1.  Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery.

Authors:  R M Comeau; A F Sadikot; A Fenster; T M Peters
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

2.  Stability of miniature electromagnetic tracking systems.

Authors:  Kurt Schicho; Michael Figl; Markus Donat; Wolfgang Birkfellner; Rudolf Seemann; Arne Wagner; Helmar Bergmann; Rolf Ewers
Journal:  Phys Med Biol       Date:  2005-04-20       Impact factor: 3.609

3.  Stereotactic catheter navigation using magnetic resonance image integration in the human heart.

Authors:  Timm Dickfeld; Hugh Calkins; Dave Bradley; Stephen B Solomon
Journal:  Heart Rhythm       Date:  2005-04       Impact factor: 6.343

4.  Registration of three-dimensional left atrial computed tomographic images with fluoroscopy.

Authors:  Jasbir Sra; David Krum; Barry Belanger; Regis Vaillant
Journal:  Heart Rhythm       Date:  2005-09       Impact factor: 6.343

5.  Catheter ablation of atrial fibrillation guided by registered computed tomographic image of the atrium.

Authors:  Jun Dong; Timm Dickfeld; Sameh Z Lamiy; Hugh Calkins
Journal:  Heart Rhythm       Date:  2005-09       Impact factor: 6.343

6.  A novel phantom-less spatial and temporal ultrasound calibration method.

Authors:  Ali Khamene; Frank Sauer
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

7.  Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery.

Authors:  R Rohling; P Munger; J M Hollerbach; T Peter
Journal:  J Image Guid Surg       Date:  1995

8.  Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation.

Authors:  M Haïssaguerre; P Jaïs; D C Shah; L Gencel; V Pradeau; S Garrigues; S Chouairi; M Hocini; P Le Métayer; R Roudaut; J Clémenty
Journal:  J Cardiovasc Electrophysiol       Date:  1996-12

9.  An event-driven distributed processing architecture for image-guided cardiac ablation therapy.

Authors:  M E Rettmann; D R Holmes; B M Cameron; R A Robb
Journal:  Comput Methods Programs Biomed       Date:  2009-03-13       Impact factor: 5.428

  9 in total
  1 in total

1.  On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic.

Authors:  Cristian A Linte; Katherine P Davenport; Kevin Cleary; Craig Peters; Kirby G Vosburgh; Nassir Navab; Philip Eddie Edwards; Pierre Jannin; Terry M Peters; David R Holmes; Richard A Robb
Journal:  Comput Med Imaging Graph       Date:  2013-02-08       Impact factor: 4.790

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.