Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system.

Iacovos S Kyprianou1, Stephen Rudin, Daniel R Bednarek, Kenneth R Hoffmann.   

Abstract

Detector characterization with modulation transfer function (MTF) and detective quantum efficiency (DQE) inadequately predicts image quality when the imaging system includes focal spot unsharpness and patient scatter. The concepts of MTF, noise power spectrum, noise equivalent quanta and DQE were referenced to the object plane and generalized to include the effect of geometric unsharpness due to the finite size of the focal spot and the effect of the spatial distribution and magnitude of x-ray scatter due to the patient. The generalized quantities provide performance characteristics that consider the complete imaging system, but reduce to a description of the detector properties without magnification or scatter. We have evaluated a new neurovascular angiography imaging system based on a region of interest (ROI) microangiographic detector using these generalized quantities. A uniform head-equivalent phantom was used as a filter and x-ray scatter source. This allowed the study of all properties of the detector under clinically relevant x-ray spectra and x-ray scatter conditions. Realistic focal spots (0.8 mm nominal), beam energies (60-100 kVp), and detector exposures (0.8-2.3 mR) were used, and the effects of different scatter fractions (0-0.62) resulting from changing the beam size (0-100 cm2) were investigated. The generalized MTF and DQE were found to have very little dependence on the tube voltage and the detector entrance exposure. Magnification, with the focal spot used, results in a large decrease of the generalized DQE at higher frequencies (about 100-fold at 10 cycles/mm), but a significantly smaller decrease at lower frequencies. Scatter on the other hand, causes a constant drop in the generalized DQE (factor of 3 for scatter fraction 0.3) for all frequencies. Our results show that there are tradeoffs in the choice of the different system parameters; therefore this methodology of studying the imaging system as a whole could provide guidance in system design.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15789608     DOI: 10.1118/1.1844151

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  33 in total

1.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

3.  Information entropy measure for evaluation of image quality.

Authors:  Du-Yih Tsai; Yongbum Lee; Eri Matsuyama
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

4.  A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems.

Authors:  G K Yadava; A T Kuhls-Gilcrist; S Rudin; V K Patel; K R Hoffmann; D R Bednarek
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

5.  Singular value description of a digital radiographic detector: theory and measurements.

Authors:  Iacovos S Kyprianou; Aldo Badano; Brandon D Gallas; Kyle J Myers
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

6.  A CMOS-based high resolution fluoroscope (HRF) detector prototype with 49.5 μm pixels for use in endovascular image guided interventions (EIGI).

Authors:  M Russ; A Shankar; S V Setlur Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

7.  Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

Authors:  M Russ; A Shankar; A Jain; S V Setlur Nagesh; C N Ionita; C Scott; K S Karim; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

8.  New Family of Generalized Metrics for Comparative Imaging System Evaluation.

Authors:  M Russ; V Singh; B Loughran; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

9.  A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array.

Authors:  Jongduk Baek; Bruno De Man; Jorge Uribe; Randy Longtin; Daniel Harrison; Joseph Reynolds; Bogdan Neculaes; Kristopher Frutschy; Louis Inzinna; Antonio Caiafa; Robert Senzig; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  Overcoming x-ray tube small focal spot output limitations for high-resolution region of interest imaging.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.