A finite element analysis of the push-out test: influence of test conditions.

W J Dhert1, C C Verheyen, L H Braak, J R de Wijn, C P Klein, K de Groot, P M Rozing.   

Abstract

The commonly used method for quantitative evaluation of the strength of a bone-implant interface is the push-out test. In order to give an impulse to standardization and to gain more insight in the biomechanics of the push-out test, a finite element analysis of this test was performed. This study focused on the influence of test conditions on the push-out results. The influence of the following four parameters on the interface stress distribution was tested: (a) clearance of the hole in the support jig, (b) Young's modulus of the implant; (c) cortical thickness; and (d) implant diameter. The distance between the implant and the support jig turned out to be very critical for the occurrence of peak stresses in the interface. Variations of the Young's modulus of the implants resulted in a wide range of interface shear stresses. Variation of the cortical thickness showed a reciprocal relationship between cortical thickness and interface shear stress. However, the interface stress distribution remained uniform under the specific test circumstances. These findings also hold for variations in implant diameter. The present investigation shows that the clearance of the hole in the support jig, and the Young's modulus of the implant are parameters which most strongly influence the interface stress distribution. The clearance of the hole in the support jig is the most critical parameter, but also the parameter that can be controlled most easily. Lack of standardization with regard to these parameters can lead to uninterpretable test results. It is recommended that the clearance of the hole in the support jig is at least 0.7 mm and that push-out results are only compared with each other when materials with similar Young's modulus are concerned.

Mesh:

Year:  1992        PMID: 1577832     DOI: 10.1002/jbm.820260111

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  30 in total

1.  Factors affecting the static shear strength of the prosthetic stem-bone cement interface.

Authors:  Jian-Sheng Wang; Mark Taylor; Gunnar Flivik; Lars Lidgren
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

2.  Uncultured marrow mononuclear cells delivered within fibrin glue hydrogels to porous scaffolds enhance bone regeneration within critical-sized rat cranial defects.

Authors:  James D Kretlow; Patrick P Spicer; John A Jansen; Charles A Vacanti; F Kurtis Kasper; Antonios G Mikos
Journal:  Tissue Eng Part A       Date:  2010-10-12       Impact factor: 3.845

3.  A novel in vivo method for quantifying the interfacial biochemical bond strength of bone implants.

Authors:  Young-Taeg Sul; Carina Johansson; Tomas Albrektsson
Journal:  J R Soc Interface       Date:  2009-04-15       Impact factor: 4.118

Review 4.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

5.  Assessment of Osstell™ and Periotest® systems in measuring dental implant stability (in vitro study).

Authors:  Samer Al-Jetaily; Abdullah Alfarraj Al-Dosari
Journal:  Saudi Dent J       Date:  2010-11-13

6.  Osseointegration of polyethylene implants coated with titanium and biomimetically or electrochemically deposited hydroxyapatite in a rabbit model.

Authors:  Caroline Scemama; Bertrand David; Morad Bensidhoum; Moussa Hamadouche
Journal:  Int Orthop       Date:  2014-05-24       Impact factor: 3.075

7.  The effect of soaking allograft in bisphosphonate: a pilot dose-response study.

Authors:  Thomas Jakobsen; Jørgen Baas; Joan E Bechtold; Brian Elmengaard; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-09-18       Impact factor: 4.176

8.  Timing of femoral prosthesis insertion during cemented arthroplasty: cement curing and static mechanical strength in an in vivo model.

Authors:  Stephen Hunt; Craig Stone; Shane Seal
Journal:  Can J Surg       Date:  2011-02       Impact factor: 2.089

9.  Bone ingrowth potential of electron beam and selective laser melting produced trabecular-like implant surfaces with and without a biomimetic coating.

Authors:  J E Biemond; G Hannink; N Verdonschot; P Buma
Journal:  J Mater Sci Mater Med       Date:  2012-12-21       Impact factor: 3.896

10.  The effect on bone growth enhancement of implant coatings with hydroxyapatite and collagen deposited electrochemically and by plasma spray.

Authors:  Henrik Daugaard; Brian Elmengaard; Joan E Bechtold; Thomas Jensen; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2010-03-01       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.