Literature DB >> 15348539

Factors affecting the static shear strength of the prosthetic stem-bone cement interface.

Jian-Sheng Wang1, Mark Taylor, Gunnar Flivik, Lars Lidgren.   

Abstract

Debonding of the stem-cement interface has been implicated in the initiation of failure of cemented femoral stems. The objective of this work was to examine some of the parameters which influence the interface static shear strength, including surface finish, cement type, pre-treatments and porosity. Surface finish was found to have the greatest effect on the interface strength. Increasing the surface roughness by a factor of 100 increases the interface shear strength by a factor of 20. However, increasing the surface roughness above a certain value was found to have no additional affect. This was due to failure in the cement itself rather than at the cement-stem interface. There were significant differences between some of the different cement types regarding the interface strength. Pre-heating the stem produced a six fold reduction in cement porosity at the stem-cement interface, however, resulting in only a minor influence on the static interface strength. Generally, no significant correlation was found between the cement porosity and the static interfacial shear strength.

Entities:  

Year:  2003        PMID: 15348539     DOI: 10.1023/a:1021501520479

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  20 in total

1.  A finite element analysis of the push-out test: influence of test conditions.

Authors:  W J Dhert; C C Verheyen; L H Braak; J R de Wijn; C P Klein; K de Groot; P M Rozing
Journal:  J Biomed Mater Res       Date:  1992-01

2.  Porosity reduction in bone cement at the cement-stem interface.

Authors:  N E Bishop; S Ferguson; S Tepic
Journal:  J Bone Joint Surg Br       Date:  1996-05

3.  Cemented femoral component surface finish mechanics.

Authors:  R D Crowninshield; J D Jennings; M L Laurent; W J Maloney
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

4.  Fatigue model to characterize cement-metal interface in dynamic shear.

Authors:  P C Chen; J G Pinto; E H Mead; D D D'Lima; C W Colwell
Journal:  Clin Orthop Relat Res       Date:  1998-05       Impact factor: 4.176

5.  Cement debonding process of total hip arthroplasty stems.

Authors:  N Verdonschot; R Huiskes
Journal:  Clin Orthop Relat Res       Date:  1997-03       Impact factor: 4.176

6.  The effect of a thin coating of polymethylmethacrylate on the torsional fatigue strength of the cement-metal interface.

Authors:  J P Davies; G Singer; W H Harris
Journal:  J Appl Biomater       Date:  1992

7.  The effect of surface preparation on metal/bone cement interfacial strength.

Authors:  K J Bundy; R W Penn
Journal:  J Biomed Mater Res       Date:  1987-06

8.  Extensive porosity at the cement-femoral prosthesis interface: a preliminary study.

Authors:  S P James; T P Schmalzried; F J McGarry; W H Harris
Journal:  J Biomed Mater Res       Date:  1993-01

9.  Factors affecting surgical alloy/bone cement interface adhesion.

Authors:  J C Keller; E P Lautenschlager; G W Marshall; P R Meyer
Journal:  J Biomed Mater Res       Date:  1980-09

10.  Tensile bonding strength of the cement-prosthesis interface.

Authors:  J P Davies; W H Harris
Journal:  Orthopedics       Date:  1994-02       Impact factor: 1.390

View more
  4 in total

1.  Fatigue debonding of the roughened stem-cement interface: effects of surface roughness and stem heating conditions.

Authors:  Leatha A Damron; Do-Gyoon Kim; Kenneth A Mann
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-07       Impact factor: 3.368

2.  Static shear strength between polished stem and seven commercial acrylic bone cements.

Authors:  Hongyu Zhang; Leigh Brown; Liam Blunt
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

3.  Effect of antibiotic loading on the shear strength at the stem-cement interface (Shear strength of antibiotic loaded cement).

Authors:  Onder Kilicoglu; L Ozgur Koyuncu; V Emre Ozden; Ergun Bozdag; Emin Sunbuloglu; Onder Yazicioglu
Journal:  Int Orthop       Date:  2007-03-14       Impact factor: 3.075

4.  Random damage and characteristics of debris particles are two important and yet ignored factors in the mechanical integrity of the stem-cement interface of a total hip replacement: influence of the surface finish of the metal stem.

Authors:  Gang Qi; Steven F Wayne; Kenneth A Mann; Bin Zhang; Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2009-11-28       Impact factor: 3.896

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.